Product Overview and Models
The PHV series are a new family of Precision High Voltage, Programmable AC to DC Power Supplies that offer exceptional performance and versatility with full local control and a complete range of optional Analog and Digital remote interfaces.
This series features Output voltages from 125V to 300,000V and power levels from 14Watts to 15,000Watts. Single-phase 115VAC Inputs (104-126VAC, 47-63Hz) are available for models rated at 1400W and lower, with Three-phase 208VAC Inputs (187-228VAC, 47-63Hz) above 1400W, all with Passive Power-Factor Correction (PF=0.72 for single phase, PF=0.92 for three phase inputs @ rated load).
Multiple remote programming interfaces are available including Analog and Isolated Analog Program/Monitor, and Digital Interfaces such as IEEE, LAN, USB, and RS232 – see the Technical Details Tab for a full description.
All models are CE Marked in accordance with the Low Voltage and EMC Directives, and are RoHS compliant and offer a three (3) year Warranty.
The PHV model table below can be sorted by any column, just click on the column header to sort ascending or descending.
Ordering Information
Model
|
Voltage
in kV
|
Polarity |
Current
in milliA
|
|
Factory Option
(see technical details
for a full list)
|
|
AC Input
|
PHV
|
60 |
P |
250 |
– |
ANA |
– |
1P115 |
|
|
N |
|
|
INA |
|
3P208 |
|
|
F |
|
|
IEEE |
|
|
|
|
R |
|
|
LAN |
|
|
|
|
|
|
|
USB |
|
|
|
|
|
|
|
RS2 |
|
|
Technical Details
The PHV series of programmable AC/DC power supplies sets a new standard for high precision, low ripple, reliable power systems for Scientific, Industrial and Laboratory applications. Available in power levels from 14W to 15kW and with output voltages from 125V to 300,000V, the PHV family offers a versatile solution for many precision high voltage applications.
All PHV models feature standard local controls with 10-turn Voltage and Current potentiometers, and 4½ digit voltage/current displays. For increased programming accuracy, optional fine potentiometers can be added for voltage and/or current control. The HV Output can be turned ON and OFF via a front panel push button, and the output voltage can be limited using a front panel mounted potentiometer.
PHV supplies are avilable with a wide range of optional analog and digital interfaces (details below), and optional features that suit many applications, including ultra low ripple, and high stability and many others that are detailed below.
Optional Features
If the standard unit configuration does not meet the users needs, a multitude of available features can increase the flexibility and performance of the PHV supply. A full list and outline description of the optional features is shown in the table below.
Isolated Output |
Standard on all models rated at 2kV and below, option for models from 3.5kV to 65kV. |
Polarity Reversal |
Electronic output polarity reversal control for all models from 3.5kV to 35kV. For 65kV models the polarity reversal option is a manual control, and adds 2U (3.5″) to the unit height, and 4″ to the depth. |
Interlock Terminals |
Shuts down unit and disconnects AC line when activated, requires RESET button to be pushed to restart unit. |
5½ Digit V/I display |
Replaces the standard 4½ with 5½ digit diplays on either current, voltage or both channels. |
Coarse/Fine output potentiometers |
Adds 10-turn potentiometer for fine adjustment of output voltage/current or both channels. |
Low ripple |
< 0.001% peak to peak ripple with additional output filtering. |
High Stability |
Hgh stability feedback components in voltage and/or current channel for improved performance ±0.001%/°C |
HV output <50V |
Indicates HV output is lower that 50V. |
Low Stored Energy |
Reduced stored energy in output section, can cause increase in output ripple to around 1%. |
Overcurrent trip |
Adds front panel potentiometer for setting output current limit. |
Power regulation |
Adds aditional regulation loop, potentiometer, and display for power control. |
Temperature controlled fan |
Turns fan on only when unit is running at high power. Not available with high stability options. |
Other features may be available, please contact the factory to discuss your exact requirements. |
Remote Interface Options
An Optional Analog control interface offers remote voltage and current programming/readback (0-10V=0-100%) as well as basic status functions that mirror the front panel LEDs and controls. The Analog interface is also available with Isolated programming/readback and status/controls (2,000V isolation) which must be used if the floating return is selected.
A comprehensive range of Optional digital interfaces is also available. This includes IEEE 488, LAN, USB, RS232 (hard wired or optical), and RS422 (hard wiredl) – see details in the specification below.
All models are CE Marked and offer three (3) year Warranty.
For more information about the PHV AC/DC Programmable Power Supply Series, contact the TDK-Lambda Americas High Power Division directly at +1-800-665-7301 or online at – Sales
A wide range of other TDK-Lambda High Power Division Low Voltage and High Voltage power supplies can be viewed from the website: website
Specifications
AC Input
Single phase 115VAC (up to 1400W outputs)
103-126VAC 47-63 Hz, PF=0.72Three phase 208VAC (>1400W outputs)
188-253VAC 47-63 Hz, PF=0.92
AC Connector
IEC60320 C14 socket (up to 750W outputs)
Phoenix HDFK4 terminal block (1400W and higher outputs)Efficiency
Better than 90% at full load and nominal lineSafety
CE Marked, EN61010-1 compliantEMC
EN61000-6-1 and EN61000-6-3 (for 1P115 input)
EN61000-6-2 and EN61000-6-4 (for 3P208 input)Output Control
Continuous adjustment from 0 to rated voltage/current by potentiometers with 10 turn precision scale, and locking control. Option for coarse/fine potentiometers.
Output Range: 0.1% to 100% of rated
Set Point Resolution: ±0.01% of rated
Polarity
Models ≤ 2kV have standard Floating return (F),
Models >2kV specify Positive (P), Negative (N),
or optional electronic Reversible (R) polarity up to 35kV, with manual reversible polarity at 65kVOutput Characteristics
Regulation (Line) – CV/CC: ±0.001%
Regulation (Load) – CV/CC: <0.02% no load to full load
Recovery Time – Voltage Control: < 1ms for load changes from 10% to 100% or from 100% to 10%
Recovery Time – Current control: < 10ms for load changes causing an output change of less than 10% of the rated voltage
Setting time at nominal load – < 500ms for output voltage changes from 10% to 90% or 90% to 10%
Ripple
Models ≤2kV & ≤350W – <0.005% +50mV p-p, 0.001% optional
Models ≤2kV & ≥700W – <0.02% +200mV p-p, 0.001% optional
Models >2kV – <0.01% +50mV p-p, 0.001% optional
Stability
< ±0.01% over 8hours under constant conditions, 0.001% optional
Temperature Coefficient
< ±150ppm per °C typical
Ambient Temperature
0°C to +40°C operating
Humidity
0-75%, non-condensing
Altitude
Operating: 6,500ft (2,000m)
HV Output Connection
125V to 350V models – 4mm banana plug terminals
650V to 300kV models – mating HV connector and 9ft HV cable (s) supplied
|
|
HV Insulating Medium
Outputs < 12kV are air insulated
Outputs > 12kV use solid dielectric silicone encapsulation
Front Panel
Locking 10-turn Voltage and Current controls with precision scale, 4½ Digit Voltage and Current meters, Power switch, HV ON/OFF switch, View Set button, CC/CV indicator, Temperature Fault LED, Overvoltage set point control, Local/Remote select
Mechanical
See dimensions and weight listed on Overview tab
Rack adapters are available for the front panel to allow 8.75″ and 17.5″ units to mount to standard 19″ racks.
PRA3 – Rack adapter for 17.5″ x 3U
PRA5 – Rack adapter for 17.5″ x 5U
PRA6 – Rack adapter for 17.5″ x 6U
PRA7 – Rack adapter for 17.5″ x 7U
PRA8 – Rack adapter for 17.5″ x 8U
PRA9 – Rack adapter for 17.5″ x 9U
PRH1 – Rack adapter for 8.75″ x 3U unit with blank filler panel
PRH2 – Rack adapter/joining kit for 2pcs x 8.75″ x 3U
Units must be supported on an appropriate shelf if rack mounted.
Protection
Open/short circuits, Overloads, Arcs, Overtemp, Overvoltage, Flashover
Analog Interface Option (ANA)
(factory installed, embedded)
0-10V analog programming/readback
HV ON/OFF control/readback
CC/CV status
Output polarity control/readback (if reversible polarity installed)
Isolated Analog Interface Option (INA)
(replaces standard Analog I/F)
(factory installed, embedded)
Isolated analog programming (0-10V)
The INA option should be specified for units with floating return
Digital Interface Options (one per unit)
(factory installed, embedded)
• IEEE: GPIB (IEEE 488) interface
• LAN: LAN/Ethernet interface
• USB: USB interface
• RS2: RS 232 with hard wire connections
• RS4: RS 422 with hard wire connections
• ROS2: RS 232 with optical fiber connections
Optional Features
(factory installed, embedded)
• INT: Interlock terminals
• I5/V5: 5½ digit diplays on either current or voltage channels
• VI5: 5½ digit diplays on both current and voltage channels
• FPI: Coarse/Fine current potentiometers
• FPV: Coarse/Fine voltage potentiometers
• LR: Output ripple < 0.001% peak to peak
• LRVS: Output ripple & voltage stability < 0.001% peak to peak
• 50V: Indicates HV output <50V
• OCP: Overcurrent trip
• PR: Power regulation
• IS: Current stability < ±0.001% over 8 hours
• VS: Voltage stability < ±0.001% over 8 hours
• VIS: V/I stability < ±0.001% over 8 hours
• LRVIS: Ripple & V/I stability < ±0.001% over 8 hours
• LN: Temperature controlled fan
|
|
Reviews