1 800 665 7301 | info@tmetrix.com

  • Multiple Bandwidth Options: 100 MHz, 200 MHz, and 350 MHz
    Fast Sampling Rate: Up to 2 GS/s (interleaved) for high-speed signal acquisition
    Extended Memory Depth: Up to 28 Mpts per channel for capturing intricate signal variations
    Serial Bus Trigger and Decode: Built-in support for I2C, SPI, UART, RS232, CAN, LIN
    Waveform Sequence Recorder: Capture and playback up to 80,000 recorded waveforms
    Advanced Triggering System: Includes Edge, Slope, Pulse Width, Window, Runt, Interval, and Pattern triggers
    Multi-Mode Display: Supports color temperature mapping and intensity grading for signal clarity
    MSO Upgrade Option: 16 digital channels available for mixed-signal debugging (on 4-channel models)
    Connectivity: USB, LAN, and external trigger output for remote data transfer and PC control

     

    Select options This product has multiple variants. The options may be chosen on the product page
    Learn More
    • Bandwidth Options: 100 MHz, 200 MHz, 350 MHz, and 500 MHz.
    • Sampling Rate: Up to 2 GS/s (1 GS/s per channel in four-channel mode).
    • Memory Depth: Up to 200 Mpts in interleaved mode for extended signal capture.
    • High-Speed Capture: Waveform update rates of 120,000 wfm/s in standard mode and up to 500,000 wfm/s in sequence mode.
    • Advanced Triggers: Edge, Slope, Pulse Width, Window, Runt, Interval, Dropout, Pattern, and Serial triggering.
    • MSO Functionality: Optional 16 digital channels for mixed-signal analysis.
    • Waveform Recorder: History Mode allows users to store and replay up to 90,000 waveforms.
    • Comprehensive Math Functions: Includes FFT, differentiation, integration, and enhanced resolution modes.
    • 256-Level Intensity Grading: Color temperature display for identifying rare signal events.
    • Connectivity: USB Host, USB Device, LAN, and External Trigger support for seamless data transfer and remote control.

     

    Select options This product has multiple variants. The options may be chosen on the product page
    Learn More
    • High Bandwidth & Sampling Rate: Models available in 200 MHz, 350 MHz, 500 MHz, and 1 GHz with up to 5 GS/s sample rate.
    • Deep Memory Capture: Up to 250 Mpts in interleaved mode, allowing detailed waveform analysis.
    • Advanced Triggering & Waveform Capture: Zone Triggering, History Mode (100,000 waveforms), and a waveform capture rate of 500,000 wfm/s.
    • Math & Measurement Functions: 9 basic math functions (FFT, addition, subtraction, multiplication, division, etc.) and 50+ automatic measurement parameters.
    • Bode Plot & Power Analysis: Standard features include Bode Plot for frequency response testing and comprehensive power analysis for applications like power quality assessment, current harmonics, inrush current, and switching loss.
    • Mixed Signal Debugging: Optional 16-channel MSO capability for digital signal acquisition.
    • Connectivity & Remote Access: USB, LAN, and embedded web server for remote control and data analysis.

     

    Select options This product has multiple variants. The options may be chosen on the product page
    Learn More
  • -60° to +200°C

    • Economy model with high thermal capacity
    • Precise temperatures with fast transitions from -60 to 200°C
    • No annual leak testing required per EU 517/2014 F-Gas Regulation
    • Effective testing and conditioning of electronic components, boards, and modules
    • Available for 50 and 60Hz operation
    • No need for Liquid Nitrogen (LN2) or Liquid Carbon Dioxide (LCO2)
    • Remote communications and set up and touch screen operation
    • User Defined Temperature Limits

     

     

    • Dynamic set up: During a simple frame reading, users can define elements to be acquired, recorded, visualized and surveyed in real time.
    •  Macro-command: Users can write and execute complex test sequences thanks to macro-command functions.
    •  Local & Distant Integration: AT-DIAG can be driven and interrogated by external software. It can also be used with a computer through Ethernet.
    • Communication ports: Communication is done through RS232, NI CAN acq. Card, specific acquisition card or system.
    •  Protocols: FREERUNNING, KWP2000, CAN, LIN, FlexRay, ARINC, … Possibility to implement new protocols (customized protocol, …).
    •  Multi-product & Multi-protocol Communication: Communication can be set up with multiple addresses and protocols during a single test.

     

    • 1 software for all your equipment
    • 1 software for all standards
    • 1 software for your electrical and EMC tests
    • Advanced functions of monitoring and control
    • Automated reports
    • Team of specialists at your disposal

     

    • Fast: ACA compression and parallelization allow to speed up the calculation
    • Accurate: Fully validated with measurement results on real mock-up
    • Innovative: New method from research labs
    • Powerful: Compute very large models
    • Easy: Dedicated graphical user interface with modern layout

     

    • Fast: ACA compression and parallelization allow to speed up the calculation
    • Accurate: Fully validated with measurement results on real mock-up
    • Innovative: New method from research labs
    • Powerful: Compute very large models
    • Easy: Dedicated graphical user interface with modern layout

     

    • Unique user interface for all tests
    • Independent from any measuring device manufacturers
    • Free drivers and over 500 supported devices
    • Efficient and dedicated Technical support
    • Wide range of supported standards (ENxx, CISPR, AUTOMOTIVE, DO160, …)
    • Interface Agilent VEE™, WindowsLabView™, LabWindows CVI™, Visual C++
    • Operating system: Win XP, Vista, Seven, Windows 8
    • Report in MS Office™ 2003, 2007, 2010, 2013, Open office