  • A versatile and cost-effective interoperability test solution for HDMI 1.4 source devices, designed to streamline R&D debugging and automated testing.

    Key Features:

    • HDMI 1.4 and DisplayPort interface support
    • Compatible with TSI Test System Interface API
    • Ready-made test routines for streamlined functionality testing
    • Comprehensive analysis of video, audio, CEC, and metadata
    • Ideal for testing Blu-Ray players, laptops, set-top boxes, game consoles, and tablets
    • Supports both R&D debugging and test automation environments

     

  • The T3VNA Series from Teledyne Test Tools is a powerful, compact solution for engineers who demand precision and versatility in RF and spectrum analysis.

    Key Features:

    • Vector Network Analysis from 10 MHz to 3.2 GHz
    • Spectrum Analysis from 9 kHz to 3.2 GHz
    • All-digital IF technology for clean signal processing
    • Built-in tracking generator (up to 1.5 GHz)
    • Advanced features like Distance-to-Fault, OBW, ACPR
    • -156 dBm/Hz typical displayed average noise level
    • -98 dBc/Hz @ 10 kHz offset phase noise
    • 1 Hz minimum RBW for high-resolution measurements
    • 10.1″ WVGA display for smooth operation
    • High accuracy with <1.2 dB amplitude error
    • Versatile Current Sensing: Accurately measure small and large currents, from sub-milliamp levels to thousands of amps.
    • High-Speed Pulse Monitoring: Patented distributed termination technology enables ultra-fast rise time measurement (as short as 2ns).
    • Enhanced Noise Immunity & Safety: Double shielding minimizes external noise, making these monitors ideal for high-voltage applications.
    • Robust Construction: Sealed models are suitable for high-voltage insulating oil or vacuum environments.
    • Broad Compatibility: Works with oscilloscopes, spectrum analyzers, power analyzers, digital voltmeters, ADCs, and more.

     

    Select options This product has multiple variants. The options may be chosen on the product page
    Learn More
  • High-Precision Current Measurement with BNC Connectivity

    • Precision Current Sensing: ±1% accuracy ensures reliable real-time current monitoring.
    • BNC Connector for Seamless Connectivity: Works with oscilloscopes, ADCs, spectrum analyzers, and power analyzers.
    • Clamp-On Design for Non-Intrusive Measurement: Safely monitor live current flow without circuit disruption.
    • 50 Ohm Termination Compatible: Output reduces by half when using a 50Ω termination.
    • High-Voltage Safety Considerations: Conductive case requires adequate insulation for user safety.

     

    Select options This product has multiple variants. The options may be chosen on the product page
    Learn More
  • High-Precision Current Sensing with BNC Connectivity

    • High-Precision Measurement: ±1% accuracy for reliable current sensing.
    • Customizable Configurations: Designed to meet specific user requirements for precision measurement.
    • BNC Connector for Easy Integration: Works with oscilloscopes, ADCs, spectrum analyzers, and power analyzers.
    • Non-Insulated Conductive Case: Proper insulation must be provided on the monitored conductor.
    • 50 Ohm Termination Compatibility: Using a 50Ω termination reduces the output to half.

     

  • High-Precision Voltage Measurement Up to 500kV

    • High-Voltage Measurement Capability: Supports up to 500kV in insulating oil and customizable calibration for air use.
    • Precision Division Ratios: Models with 5000:1, 10,000:1, and custom ratios, ensuring reliable voltage scaling.
    • Temperature-Compensated Accuracy: ±1% over 20°C to 80°C, providing stable voltage readings.
    • Robust Design for Harsh Environments: Sealed for high-voltage insulating oil use, with custom air calibration available.
    • Safe Operation with Ground Loop Control: The outer conductor is isolated from the case, allowing controlled grounding connections.

     

  • Precision Pulse Output Up to 500kV

    • Wide Voltage Range: Supports 100kV to 500kV pulse outputs for high-energy applications.
    • Fast Pulse Transmission: Pulse durations from 0.25 to 50 microseconds, ensuring efficient energy transfer.
    • Insulating Oil Immersion: Open-construction design for operation in high-voltage insulating oil, reducing breakdown risks.
    • Advanced Overvoltage Protection: Designed with built-in safety factors (50-100%) to prevent damage from overvoltages.
    • Reliable Flashover Protection: Corona ring-to-core insulation prevents damage from accidental flashovers.

     

  •  

    • Reliable and Repeatable solid state signal generation
    • Standard Internal/external pulse modulation
    • USB/Ethernet Control
    • 10 MHz external or internal reference
    • 100 Hz Frequency Resolution
    • Easily portable
    • Sized to fit into a single rack unit for ATE applications

     

  •  

    • Reliable and Repeatable solid state digital attenuation
    • Includes GUI, Windows and Linux SDK, LabVIEW driver
    • Programmable attenuation ramp and fading profiles
    • Operate multiple devices directly from a PC or self-powered hub
    • Easily portable USB powered device
    • USB and Ethernet control interfaces

     

  • HDO4000A oscilloscopes have 4 analog input channels, 12-bit resolution using Teledyne LeCroy’s HD4096 high-definition technology, up to 1 GHz of bandwidth and a compact form factor with a large 12.1” multi-touch display. They are ideal for debug and troubleshooting of power electronics designs, digital power management or power integrity analysis, automotive electronics systems, and deeply embedded or mechatronic designs.

     

    Select options This product has multiple variants. The options may be chosen on the product page
    Learn More
  • The WaveSurfer 3000z has a 10.1″ capacitive touch display, the longest memory, and the deepest toolbox – all at an affordable price.

    Select options This product has multiple variants. The options may be chosen on the product page
    Learn More
    • HD4096 technology provides 12-bit resolution all the time
    • 2ProBus input supports over 30 probes in 9 product categories
    • 3Long record capture of up to 25 Mpts
    • 412.1” 1280 x 800 HD capacitive touchscreen
    • 5Mixed-signal capability – debug complex embedded designs with integrated 16-channel mixed signal option
    • 6Easy connectivity with 2 USB 3.1 ports
    • 7MAUI with OneTouch user interface for intuitive and efficient operation

     

    Select options This product has multiple variants. The options may be chosen on the product page
    Learn More
    • 15.6″ 1920 x 1080 capacitive touchscreen display
    • 24 analog input channels
    • 3ProBus input supports every Teledyne LeCroy probe
    • 4MAUI with OneTouch user interface for intuitive and efficient operation
    • 5Q-Scape multi-tab display architecture
    • 6Up to 250 Mpts of acquisition memory
    • 7HD4096 technology – 12 bits all the time
    • 8Buttons/indicators color-coded to associated waveform on display
    • 9Use cursors and adjust settings without opening a menu
    • 10Mixed Signal capability with 16 integrated digital channels
    • 116 USB 3.1 ports (2 front, 4 side)

     

    Select options This product has multiple variants. The options may be chosen on the product page
    Learn More
    • HD4096 technology provides 12-bit resolution up to 8 GHz and 20 GS/s
    • Up to 5 Gpts of acquisition memory enables detailed viewing of long events
    • 15.6” 1900 x 1080 Full HD capacitive touchscreen
    • ProBus2 input supports up to 8 GHz bandwidth while maintaining support for legacy ProBus probes
    • MAUI with OneTouch user interface for intuitive and efficient operation
    • Waveform Control Knobs – Control channel, zoom, math and memory traces with the multiplexed vertical and horizontal knobs
    • Color-coded panel indicators – Trigger, horizontal and vertical indicator colors correspond to the associated waveform on the display
    • Cursor/Adjust Knobs – Enable and position cursors or adjust settings and parameters without opening a menu
    • Mixed Signal Capability – Debug complex embedded designs with integrated 16-channel mixed signal capability
    • Easy connectivity with seven USB 3.1 ports (3 front, 4 side) and UHD (4k) HDMI and DisplayPort outputs

     

    • Eye diagram (a), eye mask failure (b) and IsoBER eye opening analysis (c)
    • Jitter spectrum (a) with noise floor display (b) and inverse FFT of the periodic jitter (c)
    • Data dependent jitter (DDj) plot for each bit in synch with pattern (a) and with histogram (b)
    • Time interval error (TIE) jitter track analysis
    • Jitter histograms (a) with bathtub curves (b) and CDF plot (c)
    • Intersymbol interference (ISI) plots pinpoint bit sequences that have high ISI and are sources of bit errors
    • Jitter measurements table with full details for one or more “lanes” plus reference

     

    • 15.6” 1920 x 1080 capacitive touchscreen display
    • 8 analog input channels
    • ProBus input supports every Teledyne LeCroy probe
    • MAUI with OneTouch user interface for intuitive and efficient operation
    • Q-Scape multi-tab display architecture
    • Up to 5 Gpts of acquisition memory
    • HD4096 technology – 12 bits all the time
    • Buttons/indicators color-coded to associated waveform on display
    • Use cursors and adjust settings without opening a menu
    • Mixed Signal capability with 16 integrated digital channels
    • 6 USB 3.1 ports (2 front, 4 side)
    • HDMI and DisplayPort – supports 4K (4096 x 2304) external monitor
    • Removable SSD (standard)
    • View 16 channels on one display with OscilloSYNC
    • Reference Clock Input/Output for connecting to other equipment
    • USBTMC over USB 3.1 for fast data offload

     