Showing 17–32 of 42 results


  • T3PS Series – Power Supplies by Teledyne Test Tools deliver precision, flexibility, and control in a compact form for both lab and industrial use.

    Key Features:

    • Programmable and non-programmable options with up to 4 independent outputs
    • Wide voltage and current ranges up to 60 V / 200 A / 1520 W
    • Multiple display types: TFT LCD, dual numeric, high-resolution panels
    • Output modes: Constant Voltage (CV), Constant Current (CC), Constant Resistance (CR)
    • Low ripple and fast transient response: ≤1 mVrms, ≤50 µs
    • Built-in series/parallel tracking, electronic load modes, and remote sense terminals
    • Interfaces: USB, LAN, RS-232, RS-485, Analog Control, Ext I/O
    • Advanced features: OVP, OCP, UVL, programmable slew rates, panel lock
    • Ideal for use in automotive, mobile, defense, research labs, and education
    Select options This product has multiple variants. The options may be chosen on the product page
    Learn More
  • Teledyne Test Tools T3DAQ1-16 is a powerful 16-channel Data Acquisition Unit, perfect for R&D and production testing environments.

    Key Features:

    • 16-channel input (12 multi-purpose + 4 current)
    • Built on a 6½ digit digital multimeter platform
    • Wide range of electrical measurements: voltage, current, resistance, capacitance, frequency
    • True-RMS accuracy for AC voltage and current
    • Large 4.3″ TFT LCD with dual-display views
    • Display modes: Histogram, Trend, Bar Graph, Statistics, or Number
    • USB Host, USB Device, and LAN connectivity
    • Cold terminal thermocouple compensation
    • Softkey interface for intuitive navigation
  • Key Features:

    • Single output up to 360W: Choose between 18V/20A or 35V/10A
    • Mixed-mode regulation for high accuracy and low noise
    • Fanless convection cooling for completely silent operation
    • Bench or rack mountable, front and rear terminals
    • OVP trip, high-resolution settings, and remote sense terminals
    • P models offer USB, RS232, LAN interfaces (GPIB optional)
    • Rotary, keypad, and step control for voltage and current
    • Non-volatile memory for storing up to 25 user presets
    • Seamless integration with Test Bridge software and automation systems

     

    Select options This product has multiple variants. The options may be chosen on the product page
    Learn More
  • The VIR Generator U8794 is a high-precision signal generation unit designed to simulate sensor outputs for ECU inspection, component testing, and maintenance applications.

    Key Features

    • Generates DC voltage, DC current, and resistance simulation signals
    • Ideal for ECU inspection, electronic component testing, and equipment maintenance
    • Eight fully isolated output channels for safe multi-signal simulation
    • High-accuracy resistance simulation with automatic current calculation
    • Designed exclusively for use with Memory HiCorder MR8740 series
    • Supports sensor simulation testing without physical sensors
    • Compact and lightweight design for bench and field environments

     

  • The Waveform Generator U8793 is a plug-and-play module for Hioki Memory HiCorders that enables arbitrary waveform output and anomaly simulation for advanced testing scenarios.

    Key Features

    • Outputs arbitrary waveform signals on up to two channels
    • Reproduces waveforms recorded with a Memory HiCorder up to 15 V
    • Generates customized arbitrary waveforms up to 15 V output
    • Built-in function generator and sweep function
    • Isolated design between unit and outputs and between channels
    • Supports anomaly simulation and scenario-based testing
    • Includes Waveform Maker software for easy waveform creation
    • Designed for use with compatible Hioki Memory HiCorder models

     

  • Applications:

    • Aerospace & Defense – Avionics, MIL-STD-704, EMC compliance, 400Hz & wild frequency testing
    • EV Charging & V2G/V2H Testing – On-board chargers, grid-tied inverters, smart grid simulation
    • Energy Storage & Renewable Systems – Home ESS, solar PV/grid-tied inverter testing
    • Industrial Power Simulation – Frequency conversion, harmonic analysis, transient simulations
    • Smart Grid & Compliance Testing – IEC 61000, RTCA DO-160, IEEE 1547, and more

     

  • Applications

    • Aerospace & Avionics – Frequency conversion (400Hz & wild frequency testing), MIL-STD compliance
    • EV Charging & Power Electronics – On-board chargers (OBC), V2G/V2H testing, battery simulation
    • Renewable Energy Systems – Solar PV/grid-tied inverter testing, home ESS & smart grid simulations
    • Power Supply & Industrial Testing – AC/DC power supply evaluation, network server & data center testing
    • Research & Development Labs – High-frequency power testing, compliance verification, transient simulations

     

  • High-Power 4-Quadrant AC & DC Power Source with Load Option

    • Powerful & Versatile: 12kVA / kW to 21kVA / kW in a 4U chassis. Parallel units up to 168kVA/kW (single cabinet)or 252kVA/kW (dual cabinet).
    • Multi-Phase Flexibility: Supports single-phase, split-phase, and three-phase configurations with AC, DC, or AC+DC output.
    • Grid Simulation & Compliance Testing: Emulates real-world power grid conditions, simulating disturbances, harmonics, and interharmonics for accurate renewable energy testing (solar inverters, EV charging, microgrid, and UPS applications).
    • Regenerative Efficiency: Over 90% energy recovery back to the grid reduces power consumption and operational costs.
    • Advanced Control & Monitoring: SmartSource Suite enables remote control via an intuitive web browser interface with LAN, USB, GPIB, and RS232 connectivity.

     

  • 4-Quadrant Programmable Load with Energy Recovery

    • Powerful & Scalable: 6kVA/kW to 21kVA/kW in a compact 4U chassis. Parallel units up to 168kVA/kW per cabinet or 252kVA/kW in dual cabinets.
    • Versatile Load Simulation: AC and DC load capability with single-phase, split-phase, and three-phase configurations.
    • Grid-Ready Compliance Testing: Supports IEEE 1547, UL 1741, IEC 61000-3, IEC 61000-4 compliance testing.
    • Energy-Efficient Regeneration: Returns over 90% of absorbed power back to the grid, reducing operational costs.
    • Dynamic Load Emulation: Simulates linear and non-linear loads, harmonics, transient conditions, and waveform distortions.
    • High-Speed Smart Control: SmartSource Suite for real-time test automation and remote monitoring.

     

  • High-Power AC/DC Load Simulator with PHIL Interface

    • Scalable Power Density: Available in 30kVA/kW, 45kVA/kW, and 55kVA/kW models, with parallel cabinets up to 550kVA/kW.
    • Versatile AC/DC Load Capability: Supports single-phase, split-phase, three-phase, and multi-channel configurations.
    • Dual Constant Power Voltage Ranges:
      • AC Voltage: 5-220V L-N / 9-380V L-L & 5-440V L-N / 9-760V L-L
      • DC Voltage: 0-335Vdc & 9-650Vdc
    • Advanced PHIL Interface (Option H): High-speed analog I/O for real-time frequency, voltage, and current control.
    • Regenerative Power Efficiency: Returns over 90% of absorbed energy back to the grid, reducing operational costs & heat dissipation.
    • Dynamic Load Simulation: Simulates harmonics, transient conditions, and waveform distortions for real-world power testing.
    • SmartSource Suite for Remote Control: Web-based monitoring and test automation via LAN, USB, GPIB, and RS232.

     

    • High Power: Ranging from  750W to 15kW.
    • User-Friendly: Easy connections via LAN (LXI 1.5), USB (2.0), RS-232/RS-485.
    • Safe & Certified: CE/UKCA marked with built-in safety.
    • Versatile: Ideal for various industries.
    • Warranty: 5 years.

     

    • Optional Interfaces: IEEE, EtherCAT, Modbus-TCP, Isolated Analog 4-20mA (IS420)
    • Output Power Levels: 1kW to 15kW, low-noise performance
    • Output Voltage/Current: Up to 1500V and 1500A
    • AC Input Options: Single-phase and three-phase with Active Power Factor Correction
    • Mechanical Options: Blank Front Panel, Air Filter Kits, Parallel Kits
    • Certifications: CE/UKCA Marked, UL/cUL/IEC/EN 61010-1
    • Warranty: 5 years

     

    • High power density, lightweight, and portable
    • Output power: 30kW, 45kW, 60kW; Output voltages: 10V to 600V
    • Advanced features: Programmable V/I Slew-Rate, Constant-Power Limit, Arbitrary Waveform Generator
    • Built-in interfaces: LAN (LXI 1.5), USB (2.0), RS-232/RS-485, Isolated Analog (5V/10V)
    • Optional interfaces: IEEE, EtherCAT, Modbus-TCP, Isolated Analog 4-20mA
    • CE and UKCA marked, worldwide safety approvals, 5-year warranty

     

     

  • Max. 108 Analog Channels, Reduce Inspection Data Transfer Time to Zero

    Key Features of HiCORDER MR8740T – High-Speed Data Acquisition:

    • Ideal for multipoint inspection of high performance boards such as ECU
    • 108ch analog to 96ch analog + 48ch logic input
    • Reduce time required to save to external media to max.1/100 compared with conventional method
    • 20 MS/s simultaneous sampling on all channels
    • Safe measurement with all analog inputs isolated
    • Supports 4K monitor to display multi-channel waveforms without overlapping
    • Measure 4 channels with 1 unit (4 ch analog Unit U8975, 4 ch DVM Unit U8991)
    • Generate constant voltage, constant current, and simulated resistance (VIR Generator Unit U8794)

     

  • High-speed 20 MS/s (*1), 32-channel, Fully Isolated Memory Recorder for On-site Jobs and R&D

    Key Features:

    • Supports a wide variety of measurements with a total of 17 plug-in modules
    • Generate and record with a single unit
    • Direct 1000 V high voltage input testing
    • High-speed sampling up to 20MS/s (*1) with fully isolated inputs
    • 32 analog channels + 16 logic ch to 20 analog channels + 64 logic ch
    • High-speed sampling with waveform judgement function
    • Soil-resistant construction strong against adverse working environments
    • Big buttons coated to withstand industrial oil and residue
    • Drop-in paper loading and one-touch setup, along with high-speed 50mm/s printing

     

    • High speed sampling of 5 MS/s ensures catching high speed phenomena
    • Isolated 4 channel input
    • Max. rated voltage to ground: 300 V AC or DC (CAT II)
    • High resolution measurement with 16 bit A/D
    • For Memory HiCorder MR6000 and MR8740T

     