1 800 665 7301 | info@tmetrix.com

    • Electrical energy is returned to the AC grid during discharge
    • 100% duty cycle standard – No system power limit, test channel rated for continuous operation at full power, allows use in testing very high power storage batteries and EV systems
    • Drive Cycle Simulation – Waveforms can be imported into the test procedure to increase test efficiency and reduce potential operator error
    • Local emergency cut-off switch, automatic shutdown on loss of AC power, reverse voltage protection, internal circuit breakers – Provides a high level of safety
    • Automatic scaling of data in W/kg or C-rate for drive cycle simulation programs and other test procedures – Reduces operator workload
    • Real-time data and graphics – Allows battery performance to be visually monitored at any time as the test progresses

     

  • Customizable Configurations for Any Environment

    • Freestanding cabinets with adjustable 19” EIA square hole rails and depths of up to 38”.
    • Wall-mounted units (cold-rolled steel or stainless steel) available in 12U and 19U sizes.
    • Outdoor-ready enclosures for harsh industrial conditions.

    Ideal for:

    • Telecom & Network Infrastructure
    • Industrial Automation & Edge Computing
    • Smart Grid & IoT Deployments
    • Military & Government Facilities

    The KARIS SRK Precision Cooling Cabinets are a space-saving, cost-effective solution for securely housing IT and industrial equipment while maintaining optimal environmental conditions.

    • Addressable Chamber Controllers allow multiple chambers to be controlled on a single Maccor test system.
    • Chamber Temperature Set Points are set directly from Maccor’s Test System Software as a step in the test procedure.
    • The compact design allows the chamber to easily fit onto a benchtop.
    • If bench top and floor space are limited, the 7U height and compact design make it possible to stack up to four chambers in a standard 19” industrial rack cabinet.
    • Electrical feedthroughs allow electrical connections inside the chamber while maintaining a maximum seal.
    • Optional interface board can be installed inside the chamber to allow a plug-in interface that can accommodate Maccor’s molded Kelvin and coin cell holders.
    • Large 3” (76 mm) diameter cable portal on the right side of the chamber.
    • Non-Conducting Powder Coated Interior.

     

    • Fully assembled design for hassle-free installation.
    • Hinged swing-out option for rear access to cables and equipment.
    • Adjustable rails and multiple cable management points.
    • Lockable side panels and glass doors for added security.
    • Compatibility with power, cooling, and shelving accessories.
    • Removable back panel for simplified mounting.
    • Durable black powder-coated finish with EIA 310-D compliance.

    The KARIS SRK Series Wall-Mount Cabinets provide an ideal solution for IT professionals and data centre managers looking for efficient, secure, and accessible equipment housing.

    • High-Density Testing – Up to 192 test positions per rack or 32 positions per desktop unit, ensuring high-throughput testing.
    • Independent Operation – Each test position operates independently, enabling simultaneous testing of multiple cells under different conditions.
    • User-Programmable Multi-Step Testing – Configure constant current, power, voltage, or resistance test sequences with easy-to-use software.
    • Precise Data Logging & Analysis – Logs current, voltage, time, temperature, and other critical parameters with high-speed data acquisition.
    • Real-Time Monitoring & Control – Data can be viewed, plotted, and analyzed in real-time, providing instant insights into cell performance.
    • Compact & Scalable Design – Available in desktop models (32 positions) and rack-mounted configurations (up to 192 positions per rack).
    • Seamless Integration – Powered by Maccor’s standard test system software, ensuring consistent performance and compatibility with existing systems.
    • Turn-Key Solution – Supplied as a complete system with PC and software, ensuring quick deployment and easy setup.
    • Advanced Safety Features – Includes automatic shutdown on power loss, reverse voltage protection, and internal circuit breakers for safe operation.
    • Versatile Applications – Suitable for single-cell testing, R&D, quality control, battery performance evaluation, and cycle life testing.

     

    • Advanced Formation Schedules – Supports up to 18 test steps with subroutines, allowing complex formation programs for Lithium-Ion and Lithium Polymer cells.
    • High Channel Density – Configurable with 512 to 2048 test channels, supporting large-scale production and pilot line testing.
    • Accurate Data Logging & Analysis – Logs Voltage, Current, Time, Capacity, Energy, and Cycle with high-speed data acquisition at 200 data points per second.
    • Flexible Test Modes – Supports Constant Current, Constant Voltage, Constant Power, and Constant Resistance operating modes.
    • Seamless Transition from Constant Current to Constant Voltage – Ensures smooth and accurate formation with no interruptions or spikes.
    • High Accuracy & Resolution –
      • Voltage Measurement Range: 0 to 5V
      • Voltage Accuracy: ±5 mV
      • Voltage Resolution: 16-bit
      • Current Resolution: 16-bit
    • Intelligent Cell Grading – Customizable grade profiles allow cell grading based on performance, ensuring consistent quality control.
    • High Scalability & Flexibility – Combine channels in parallel to increase current capability, supporting dynamic testing requirements.
    • Advanced Safety Features – Includes automatic shutdown on power failure, status recovery, and reverse voltage protection for safe operation.
    • Turn-Key Solution – Complete system with PC computer and software, ensuring quick deployment and easy setup.
    • Comprehensive Data Management – Automatic report generation, data backup, and processing with the MIMS Server Application.

     

    • Enterprise-class server.
    • Maximum system uptime
    • Designed to run 24×7, 365 days a year
    • M7© – Hosts up to 7 virtual machines representing 7 desktop computers
    • M22 © – Hosts up to 22 virtual machines representing 22 desktop computers
    • Server OS hosted on 2 Enterprise-grade SATA-SSD drives, RAID1
    • Virtual Machines hosted on shared array qty of eight (14TB) Enterprise-grade SAS-3 hard drives, RAID6
    • 2 Enterprise-grade PSU’s, 2 fans, 2 SATA Drives, 8 SAS-3 drives, all of which are hot-swappable CRU’s (customer replaceable units)

     

  • Efficient and Precise Cell Balancing

    The Maccor Cell Balancer is engineered to:

    • Independently charge and discharge each cell within a string, maintaining equal voltage levels across all cells.
    • Optimize battery pack performance by preventing cell overcharging or over-discharging, ensuring longer cycle life and enhanced safety.
    • Balance up to 8 cells per unit, with the ability to expand to larger battery packs by connecting multiple balancers in series.

    Seamless Integration with Maccor Test Systems

    The Maccor Cell Balancer is designed to integrate seamlessly with Maccor’s Mactest32.exe software, allowing users to:

    • Incorporate cell balancing steps directly into their test procedures.
    • Control and monitor cell balancing with real-time data visualization and automated data logging.
    • Customize balancing parameters, including charge and discharge currents, ensuring precision and flexibilityfor different battery chemistries and configurations.

     

    • Advanced Multi-Level Pulse (AMLP) – Design complex pulse profiles with up to 15,000 levels for high-precision battery testing.
    • Ultra-Fast Data Collection – Log data at 1 kHz across multiple channels with 20 kHz sampling for the first milliseconds, capturing critical transient events.
    • High-Resolution Step Length Control – Specify test steps as short as 750 microseconds with 1-microsecond increments, enabling ultra-fast dynamic testing.
    • High-Speed Set Point Lock-In – Achieve setpoint stabilization in as little as 1 millisecond, ensuring accurate and consistent results.
    • Customizable Waveforms – Stream external text test files with programmable waveforms, supporting constant current or power modes with 1-millisecond increments and 1-microsecond resolution.
    • Unmatched Flexibility – Run multiple unique waveforms in a single test without limitations on the number of levels.
    • Comprehensive Data Logging – Log data on current, voltage, time, and other factors continuously, providing comprehensive performance insights.
    • Optimized for Complex Testing – Ideal for cycle life testing, pulse power characterization, impedance measurements, and battery performance evaluation.
    • Scalable and Modular Design – Expand testing capabilities by integrating multiple Series 6000 units, ensuring scalable solutions for R&D and production environments.

     

    • Noise reduction of up to 31 dBA, making servers whisper-quiet.
    • Up to 12 kW heat dissipation, ensuring optimal thermal management.
    • IoT-enabled U-Telligent Management System (UMS) for remote monitoring, security, and alerts.
    • Built-in security with internal camera mounting, electronic locking, and real-time access alerts.
    • Available in 12U, 24U, and 42U heights, supporting all major server brands.
    • Flexible installation options, allow for easy integration in offices, labs, and industrial settings.
    • Energy-efficient EC fans, dynamically adjust speed based on heat load to reduce energy costs.
    • Fully enclosed design with soundproof cable entry points, maintaining maximum acoustic performance.

     

  • Single Phase Power Meter Compatible with DC Measurement and Current/Power Integration Measurement

    Key Features:

    • Compatible with the SPECpower® (*1) benchmarking for server power consumption
    • DC measurement mode, AC, and AC+DC measurement
    • Integration function for current and power
    • ±0.1% high basic accuracy (*2) For complete details, please refer to the specifications)
    • Extended period of guaranteed accuracy of 3 years
    • Complete accuracy over a wide input range

     

  • The CDG 7000 is a new test generator for all standards on immunity to conducted disturbances induced by high-frequency fields – including BCI tests (ISO 11452-4). One of the very few combined IEC 61000-4-6 test systems that contain the RF signal generator, an RF power amplifier, a 3-channel RF voltmeter, and a directional coupler at a very affordable price. IEC 60601-1-2 calling out IEC 61000-4-39 magnetic immunity for close proximity testing requirements can also now be met with the 10 kHz unit.

  • The EME Guard Plus is a lightweight and robust personal protection monitor designed to ensure the safety of workers operating near electromagnetic field (EMF) emitters such as antennas, radars, and base stations. With a frequency range of 1 MHz to 40 GHz, this device continuously monitors and records EMF exposure levels while providing immediate audio, visual, and vibrating alerts when exposure exceeds predefined safety thresholds. Customizable alarm settings and a triaxial isotropic probe ensure accurate and reliable measurements.

     

  • The EME Guard XS Radar is a state-of-the-art RF safety monitor, specifically designed for workers operating near radar transmitters and antennas. With its isotropic tri-axis E-field sensors, this compact device provides continuous EMF monitoring over a frequency range of 1 MHz to 40 GHz, including short pulsed signal detection. Equipped with audio and visual alarms, it alerts users instantly when EMF exposure exceeds predefined safety thresholds, creating a safer working environment for military, aviation, and telecom personnel.

     

  • Solutions For:

    •  Accurate measurement with tri-axis sensors
    • Instant audio and visual alarm
    • Robust, reliable and user-friendly
    • Covers 5G / 6G bands, measuring up to 71 GHz

    User profile:

    • Persons working near antennas including installation and maintenance workers, broadcast, PMR and mobile phone operators or regulatory body employees

    Measurement capabilities:

    • Continuous monitoring of Electromagnetic Field levels with isotropic tri-axis E-field sensors
    • EMF Level indicated by a LED color scale
    • Audio and visual alarms triggered when EMF exceeds the reference level
  • Max. 108 Analog Channels, Reduce Inspection Data Transfer Time to Zero

    Key Features of HiCORDER MR8740T – High-Speed Data Acquisition:

    • Ideal for multipoint inspection of high performance boards such as ECU
    • 108ch analog to 96ch analog + 48ch logic input
    • Reduce time required to save to external media to max.1/100 compared with conventional method
    • 20 MS/s simultaneous sampling on all channels
    • Safe measurement with all analog inputs isolated
    • Supports 4K monitor to display multi-channel waveforms without overlapping
    • Measure 4 channels with 1 unit (4 ch analog Unit U8975, 4 ch DVM Unit U8991)
    • Generate constant voltage, constant current, and simulated resistance (VIR Generator Unit U8794)