1 800 665 7301 | info@tmetrix.com

  • A high-performance analyzer designed for R&D applications involving electrochemical components, materials, batteries, and EDLCs. It enables precise impedance measurements essential for advanced evaluation and development.

    Key Features:

    • Wide frequency range: 1 mHz to 200 kHz for detailed ion and solution behavior analysis
    • Dual function: High-speed continuous LCR and sweep measurements with one device
    • Battery analysis: Measures internal impedance under no-load conditions
    • Ultra-fast sweep: Perform measurements in as little as 2 ms
    • High accuracy: ±0.05% basic precision for reliable R&D and testing
    • Advanced analysis: Supports Cole-Cole plots and equivalent-circuit modeling for electrochemical studies
  • An advanced firmware upgrade for the IM3570 that enables quick and accurate equivalent circuit analysis, ideal for in-depth component evaluation and quality control.

    Key Features:

    • Automatically selects the optimal equivalent circuit model from five typical options
    • Minimizes discrepancies between measured and ideal frequency characteristics
    • Determines acceptance/rejection of L, C, and R elements with precision
    • Evaluates resonance sharpness (mechanical quality coefficient)
    • Enables detailed analysis of piezoelectric elements and inductors through resonance
  • A high-speed, high-precision LCR meter ideal for low-ESR and impedance testing in advanced electronic components like polymer capacitors, inductors, and piezoelectric elements.

    Key Features:

    • Continuous LCR/DCR/sweep measurements with one instrument
    • Ultra-fast testing speeds: 1.5 ms (1 kHz), 0.5 ms (100 kHz)
    • High accuracy: ±0.08% basic accuracy for Z parameter
    • Ideal for low-ESR measurement of functional polymer capacitors
    • Suitable for resonance testing of piezoelectric elements
    • Accurate DCR and L-Q testing of inductors, coils, and transformers
  • The Hioki IM7580A is a compact, high-speed impedance analyzer for 1 MHz to 300 MHz testing, ideal for both production and R&D. It works seamlessly with the IM9201 SMD fixture for reliable component testing.

    Key Features:

    • 1 MHz to 300 MHz frequency range
    • 0.5 ms test speed
    • ±0.72% basic accuracy
    • Compact half-rack size with palm-sized test head
    • Reliable contact check functions
    • Frequency, level, and time sweeps in Analyzer Mode
    • RF I-V method for precise measurement
  • The Hioki IM7581 is a compact, high-speed impedance analyzer designed for accurate testing from 100 kHz to 300 MHz. It’s ideal for both production and development environments.

    Key Features:

    • 100 kHz to 300 MHz frequency range
    • 0.5 ms fastest test speed
    • ±0.72% basic accuracy
    • Compact half-rack size, palm-sized test head
    • Reliable contact check via DCR, Hi-Z reject, or waveform judgment
    • Supports frequency, level, and time sweeps in Analyzer Mode
    • Uses RF I-V method for precise measurement
  • The Hioki Impedance Analyzer IM7587 3 GHz provides precision, speed, and versatility for impedance measurements from 1 MHz to 3 GHz, ideal for both R&D and mass production applications in electronic component testing.

    Key Features:

    • Frequency range: 1 MHz to 3 GHz
    • Test speed: 0.5 ms
    • Measurement variability: 0.07%
    • Basic accuracy: ±0.65% reading
    • RF I-V measurement technique
    • Compact half-rack design with palm-sized test head
    • Robust contact check capabilities
    • Analyzer mode: frequency and level sweeps, time interval measurements
  • High-Precision Current Measurement with BNC Connectivity

    • Precision Current Sensing: ±1% accuracy ensures reliable real-time current monitoring.
    • BNC Connector for Seamless Connectivity: Works with oscilloscopes, ADCs, spectrum analyzers, and power analyzers.
    • Clamp-On Design for Non-Intrusive Measurement: Safely monitor live current flow without circuit disruption.
    • 50 Ohm Termination Compatible: Output reduces by half when using a 50Ω termination.
    • High-Voltage Safety Considerations: Conductive case requires adequate insulation for user safety.

     

  • The Hioki PW8001 High-Precision Power Analyzer sets the benchmark for precision power analysis, offering unmatched accuracy and flexibility for evaluating motor and inverter efficiency. Supporting DC and frequencies from 0.1 Hz to 5 MHz, it features an 8-channel measurement capacity, enabling simultaneous analysis of complex systems like EV drivetrains, renewable energy sources, and high-efficiency SiC/GaN semiconductors.

    Equipped with advanced features such as automatic phase correction, intuitive Power Spectrum Analysis (PSA), and CAN/CAN FD integration, the PW8001 excels in capturing high-speed switching power fluctuations and harmonics. Its compatibility with high-voltage systems (up to 1500 V) and seamless connectivity with industry-standard software like LabVIEW and MATLAB ensure it meets diverse testing needs. With its robust design, real-time waveform visualization, and comprehensive motor analysis functions, the PW8001 is the ultimate tool for power conversion efficiency analysis.

     

  • HDO4000A oscilloscopes have 4 analog input channels, 12-bit resolution using Teledyne LeCroy’s HD4096 high-definition technology, up to 1 GHz of bandwidth and a compact form factor with a large 12.1” multi-touch display. They are ideal for debug and troubleshooting of power electronics designs, digital power management or power integrity analysis, automotive electronics systems, and deeply embedded or mechatronic designs.

     

  • The WaveSurfer 3000z has a 10.1″ capacitive touch display, the longest memory, and the deepest toolbox – all at an affordable price.

    • HD4096 technology provides 12-bit resolution all the time
    • 2ProBus input supports over 30 probes in 9 product categories
    • 3Long record capture of up to 25 Mpts
    • 412.1” 1280 x 800 HD capacitive touchscreen
    • 5Mixed-signal capability – debug complex embedded designs with integrated 16-channel mixed signal option
    • 6Easy connectivity with 2 USB 3.1 ports
    • 7MAUI with OneTouch user interface for intuitive and efficient operation

     

    • 15.6″ 1920 x 1080 capacitive touchscreen display
    • 24 analog input channels
    • 3ProBus input supports every Teledyne LeCroy probe
    • 4MAUI with OneTouch user interface for intuitive and efficient operation
    • 5Q-Scape multi-tab display architecture
    • 6Up to 250 Mpts of acquisition memory
    • 7HD4096 technology – 12 bits all the time
    • 8Buttons/indicators color-coded to associated waveform on display
    • 9Use cursors and adjust settings without opening a menu
    • 10Mixed Signal capability with 16 integrated digital channels
    • 116 USB 3.1 ports (2 front, 4 side)

     

    • HD4096 technology provides 12-bit resolution up to 8 GHz and 20 GS/s
    • Up to 5 Gpts of acquisition memory enables detailed viewing of long events
    • 15.6” 1900 x 1080 Full HD capacitive touchscreen
    • ProBus2 input supports up to 8 GHz bandwidth while maintaining support for legacy ProBus probes
    • MAUI with OneTouch user interface for intuitive and efficient operation
    • Waveform Control Knobs – Control channel, zoom, math and memory traces with the multiplexed vertical and horizontal knobs
    • Color-coded panel indicators – Trigger, horizontal and vertical indicator colors correspond to the associated waveform on the display
    • Cursor/Adjust Knobs – Enable and position cursors or adjust settings and parameters without opening a menu
    • Mixed Signal Capability – Debug complex embedded designs with integrated 16-channel mixed signal capability
    • Easy connectivity with seven USB 3.1 ports (3 front, 4 side) and UHD (4k) HDMI and DisplayPort outputs

     

    • Eye diagram (a), eye mask failure (b) and IsoBER eye opening analysis (c)
    • Jitter spectrum (a) with noise floor display (b) and inverse FFT of the periodic jitter (c)
    • Data dependent jitter (DDj) plot for each bit in synch with pattern (a) and with histogram (b)
    • Time interval error (TIE) jitter track analysis
    • Jitter histograms (a) with bathtub curves (b) and CDF plot (c)
    • Intersymbol interference (ISI) plots pinpoint bit sequences that have high ISI and are sources of bit errors
    • Jitter measurements table with full details for one or more “lanes” plus reference

     

    • 15.6” 1920 x 1080 capacitive touchscreen display
    • 8 analog input channels
    • ProBus input supports every Teledyne LeCroy probe
    • MAUI with OneTouch user interface for intuitive and efficient operation
    • Q-Scape multi-tab display architecture
    • Up to 5 Gpts of acquisition memory
    • HD4096 technology – 12 bits all the time
    • Buttons/indicators color-coded to associated waveform on display
    • Use cursors and adjust settings without opening a menu
    • Mixed Signal capability with 16 integrated digital channels
    • 6 USB 3.1 ports (2 front, 4 side)
    • HDMI and DisplayPort – supports 4K (4096 x 2304) external monitor
    • Removable SSD (standard)
    • View 16 channels on one display with OscilloSYNC
    • Reference Clock Input/Output for connecting to other equipment
    • USBTMC over USB 3.1 for fast data offload

     

    • S-parameters DC to 40 GHz, single-ended and mixed-mode
    • Impedance Profile with <1 mm resolution, differential and common-mode
    • Internal, automatic OSLT calibration
    • USB-connected, small, lightweight
    • Flexible display of the measurements
    • Remove effects from fixtures, connectors and cables
    • Emulate eye diagrams with CTLE, DFE and FFE equalization
    • Advanced jitter analysis