1 800 665 7301 | info@tmetrix.com

  • Experience precision RF signal analysis on the go with this lightweight, handheld analyzer designed for both lab and field use.

    Key Features:

    • Frequency range: 1MHz to 1.3GHz (PSA1303) or 2.7GHz (PSA2703)
    • RBW: 300Hz to 10MHz
    • -115dBm typical noise floor
    • Dual markers with absolute/difference values
    • AM/FM demodulation in zero span
    • Auto-find & smart marker peak tracking
    • USB for waveform saving and PC connection
    • Live, View, and Reference trace modes
    • 6-hour lithium-ion battery operation
    • Weighs just 0.58 kg
    • Optional U01 Upgrade: Limit lines, data logging, triggering, compensation tables

     

  • High-performance, battery-powered spectrum analyzers ideal for RF engineers and field use.

    Key Features:

    • Frequency range: 10MHz to 3.6GHz or 6.0GHz
    • -120dBm typical noise floor
    • Resolution bandwidths from 300Hz to 10MHz
    • AM/FM audio demodulation with zero span
    • Live, View & Reference traces with markers
    • Smart marker tracking with peak detection
    • USB data logging & real-time PC view
    • Compact, lightweight (0.56 kg) with >3hr battery
    • Optional U02 features: limit lines, OBW, ACPR, AM/FM waveform demodulation

     

  • The Teledyne T3SA Series Spectrum Analyzers deliver high-performance signal analysis from 9 kHz to 3.2 GHz in a compact, easy-to-use design. Ideal for R&D, education, production, and pre-compliance testing, it features a large touchscreen and advanced digital IF technology.

    Key Features:

    • All Digital IF technology10.1”
    • WVGA (1024 x 600) touchscreen display
    • Frequency range from 9 kHz to 3.2 GHz
    • -161 dBm/Hz displayed average noise level (typical)
    • -98 dBc/Hz @ 10 kHz offset phase noise (typical)
    • Total amplitude accuracy < 0.7 dB
    • 1 Hz minimum resolution bandwidth (RBW)
    • Built-in preamplifier for improved sensitivity

    Typical Applications

    ● Research Laboratory
    ● Development Laboratory
    ● Repair and Maintenance
    ● Calibration Laboratory
    ● Automatic Production Test
    ● General bench-top use

  • High-Precision Current Sensing with BNC Connectivity

    • High-Precision Measurement: ±1% accuracy for reliable current sensing.
    • Customizable Configurations: Designed to meet specific user requirements for precision measurement.
    • BNC Connector for Easy Integration: Works with oscilloscopes, ADCs, spectrum analyzers, and power analyzers.
    • Non-Insulated Conductive Case: Proper insulation must be provided on the monitored conductor.
    • 50 Ohm Termination Compatibility: Using a 50Ω termination reduces the output to half.

     

  • Key Features:

    • Measure even harmonic waveform components using the True RMS method
    • Expanded -25°C to 65°C operating temperature range
    • Connect the CT6280 flexible sensor to measure up to 4199 A in thick or paired wires
    • Drop proof design withstands drop from a height of 1 meter

     

    • CAT IV 600 V, CAT III 1000 V
      When using P2000: CAT III 2000 V, CAT IV 1000 V
    • Easily get into tight spaces between cables thanks to thin sensor with a minimum cross-section span of 11 mm
    • Measure up to 2000 A AC
    • AC A, AC and DC V, DC+AC V, resistance, frequency, and more
    • Easily transfer measurement data to your smartphone or tablet by using our free app GENNECT Cross or to an Excel® file (*1)
    • Harmonic analysis from 1st to 30th order with GENNECT Cross (*1)

     

    • Measure the fundamental waveform component using the average rectified method
    • Expanded -25 °C to 65 °C operating temperature range
    • Connect the CT6280 flexible sensor to measure up to 4199 A in thick or paired wires
    • Drop proof design withstands drop from a height of 1 meter

    Guarantee3years  CE  DROPPROOF

  • Power Demand Analyzer (Custom 5000A Kit)

     

    • Supports single to three-phase, 4-wire circuits
    • Measure up to 780 V with a 1000 V display range
    • Simultaneously measure up to three single-phase, 2-wire circuits (in the same power system)
    • Broadly applicable for many jobs, including leakage current measurement (An optional clamp-on leakage sensor measures as low as 50 mA)
    • Store months of data on SD cards
    • Identifies your power condition to help save energy
    • The QUICK SET function guides you in making the right connections
    • Choose PW3360-21 for harmonic measurements up to the 40th order

     

  • Single-Phase and Three-Phase Handheld Power Meter with Harmonic Analysis Up to 20th Order

     

  • 3-Phase 4-Wire Portable Power Quality Analyzer to Detect, Measure and Record Power Quality Issues, Harmonics, Demand, Inrush and Power Transients

     

  • 20A to 2000A AC/DC Clamp Meter System with Waveform Output Function and Wide 1.00Hz to 1000Hz Bandwidth

  • Multi-range 1000A Voltage Output Sensor for Capturing Waveforms with DMMS, Memory HiCorders and other data acquisition equipment

  • Multi-range 500A Voltage Output Sensor for Capturing Waveforms with DMMS, Memory HiCorders and other data acquisition equipment.

  • DC to 15 kHz/2000A AC/DC Clamp On Current Probe