1 800 665 7301 | info@tmetrix.com

  • The Hioki MR6000 Memory HiCorder sets a new benchmark in waveform recording, combining cutting-edge technology, intuitive design, and world-class performance. Built from the ground up, it’s engineered to tackle both current and future measurement challenges with ease and precision.

    Key Features:

    • Large, intuitive touch panel for efficient and user-friendly operation
    • Simultaneous multi-channel isolation measurement at up to 200 MS/s (with High Speed Analog Unit U8976)
    • Significantly faster data saving for a seamless experience
    • Real-time data saving without interrupting ongoing measurements
  • The Hioki Rack-mounted Multi-channel System Recorder (MR8741/MR8740) is a powerful, high-speed, single-device solution for waveform recording and generation. Ideal for test systems, it offers high-resolution, isolated multi-channel measurements with fast sampling capabilities.

    Key Features:

    • Integrated waveform recording and generation in one device
    • Equipped with DVM Unit MR8990 for high-accuracy 24-bit resolution measurements
    • Supports up to 16 channels (MR8741) for multi-channel testing
    • Isolated input between channels and from input to chassis (up to 300 V AC/DC)
    • High-speed sampling up to 20 MS/s
    • Compact rack-mountable design (4U height, under 180 mm depth)
    • Monitor display and setting access via DVI-D and mouse
    • Enables remote measurement and control via LAN
    • Browser-based screen monitoring or advanced control via Hioki 9333 LAN Communicator
  • The Hioki Memory Recorder is a high-speed, fully-isolated data acquisition system designed for precise and simultaneous measurement of multiple analog and logic signals. Ideal for testing, simulation, and system diagnostics, it combines waveform generation and recording in one powerful unit.

    Key Features:

    • Generate and record waveforms using a single device
    • Simulate issues by outputting previously recorded problematic waveforms to test devices
    • Supports 32 analog + 32 logic channels, expandable to 28 analog + 64 logic channels
    • High-speed sampling up to 20 MS/s with fully isolated inputs
    • Ensures safe measurement with complete analog input isolation
    • Equipped with a large-capacity 512M-word memory
    • Simultaneously measures high voltage and ultra-low voltage system signals

     

  • A compact, high-performance power supply for automotive EMC and battery voltage simulation.

    Key Features:

    • Battery simulator for 12V, 24V, 42V, and 48V systems
    • Output: 0–66V / 0–55A (max)
    • Fast voltage rise time up to 100V/µs
    • ISO 7637-2 and ISO 16750-2 compliant
    • Remote control via CAR-Remote Software
    • Impulse Recording Function (IRF) included
    • Compact 19-inch desktop form (15 kg only)
    • Overvoltage and thermal protection
    • Slew rate: 10V/µs with fan cooling system
    • Compatible with HILO CAR-SYS test systems

     

  • High-performance power simulator designed for advanced EMC and automotive voltage testing.

    Key Features:

    • Supports 12V, 24V, 42V, 48V, and 70V automotive systems
    • Battery simulation with up to 220A current
    • Fast voltage rise time up to 100V/µs
    • ISO 7637-2 and ISO 16750-2 compliant
    • Integrated Impulse Recording Function (IRF)
    • Full remote control via CAR-Remote software
    • Ethernet interface and built-in safety interlock
    • Cooling via fans and heat sink for reliable operation
    • Compact 19-inch rackmount desktop system (60 kg)
    • Overvoltage and thermal protection included

     

  • Teledyne Test Tools T3DAQ1-16 is a powerful 16-channel Data Acquisition Unit, perfect for R&D and production testing environments.

    Key Features:

    • 16-channel input (12 multi-purpose + 4 current)
    • Built on a 6½ digit digital multimeter platform
    • Wide range of electrical measurements: voltage, current, resistance, capacitance, frequency
    • True-RMS accuracy for AC voltage and current
    • Large 4.3″ TFT LCD with dual-display views
    • Display modes: Histogram, Trend, Bar Graph, Statistics, or Number
    • USB Host, USB Device, and LAN connectivity
    • Cold terminal thermocouple compensation
    • Softkey interface for intuitive navigation
  • The CDG 7000 is a new test generator for all standards on immunity to conducted disturbances induced by high-frequency fields – including BCI tests (ISO 11452-4). One of the very few combined IEC 61000-4-6 test systems that contain the RF signal generator, an RF power amplifier, a 3-channel RF voltmeter, and a directional coupler at a very affordable price. IEC 60601-1-2 calling out IEC 61000-4-39 magnetic immunity for close proximity testing requirements can also now be met with the 10 kHz unit.

    • Frequency Range:
      • 10 kHz – 30 MHz Conducted
      • 5 MHz – 1GHz Radiated
    • Frequency step:
      • 10/500 kHz switchable CE
      • 5/10 MHz switchable RE
    • Includes: Generator, antenna, charger, wood case

     

    • 10 kHz – 3 GHz, 40dB Gain, 5dB N.F.
    • Compensation for long cable loss for EMI Measurement
    • Improve system noise floor flatness
    • High EMI performance
    • High linearity LNA for EMI measurement
    • High dynamic range
    • Unconditionally Stable
    • State-of-the-Art Technology

     

    • EMI Measurements:
      • FFT-based dual-channel receiver
      • According to CISPR16-1-1
      • Peak, Quasi-Peak, and Average Detectors
      • Resolution Bandwidth Filters of 200 Hz, 9 kHz, and 120 kHz (CISPR), and 1 kHz and 10 kHz (MIL)
      • The fastest receiver in the market: Line and Neutral measurements with the 3 detectors simultaneously (6 simultaneous measurements)

     

  • The EMI 64k software allows to embed the TDEMI systems in a fully automated test environment.

    • Full automation of EMI testing according to all commercial and military standards
    • Automated control of turntable, antenna and other equipment
    • Height and Angular Scan
    • Procedures according to standards as well as customized procedures
    • Reducing the cost for EMC and communication testing and certification by tailored packages

     

  • The measurement system for all emission measurments in the frequency range 1 Hz – 44 GHz.

    • Frequency Range  1 Hz – 30MHz, 1GHz, 3GHz, 6GHz, 9GHz, 18GHz, 26GHz, 40 GHz and 44GHz
    • 225 MHz Real-time Analysis Bandwidth
    • Weighted Real-time Spectrogram up to 44 GHz
    • CISPR Bandwidths 200 Hz, 9 kHz, 120 kHz, 1 MHz
    • MIL/DO Bandwidths 10 Hz, 100 Hz, 1 kHz, 10 kHz, 100 kHz, 1 MHz

     

  • The measurement system for all emission measurments in the frequency range 1 Hz – 44 GHz.

    • Full compliance EMI Reciever according to standard CISPR 16-1· 1, ANSI C63.2, MIL->461, and DO·160
    • Spectrum Analyzer
    • Integrated LOW Noise Ampllfier (lNAI)
    • Integrated Preselect1on
    • Tradttional and FFT·based Mode
    • Automatic Stepped Attenuator
    • Ultra Low Noise Floor
    • Excellent spurious Performance
    • Real-time Spectrum Analyzer optional
    • Vast IQ-Bandwidth

     

  • TDEMI Mobile+. The ultra mobile EMI receiver – Emission measurements everytime, everywhere. Fully stand-alone operable.

    • Frequency Ranges 10Hz – 1GHz, 3GHz, 6GHz or 7GHz
    • 16000x faster than conventional receivers
    • Super compact design and 12V supply
    • 225 MHz fully gapless real-time analysis bandwidth
    • Weighted Real-time Spectrogram

     

  • Ultra High Performance RT Spectrum Analyzer. Ultrafast EMI Measurements.

    • Frequency Range from 1 Hz up to 50 GHz
    • 225 MHz Real-time analysis bandwidth
    • 100 dB Dynamic Range
    • Ultrahigh performance preselection in all modes
    • Up to 510 MHz Real-time IQ-Analysis bandwidth
    • Ultra High Performance Spectrum Analyzer

     

     

  • Max. 108 Analog Channels, Reduce Inspection Data Transfer Time to Zero

    Key Features of HiCORDER MR8740T – High-Speed Data Acquisition:

    • Ideal for multipoint inspection of high performance boards such as ECU
    • 108ch analog to 96ch analog + 48ch logic input
    • Reduce time required to save to external media to max.1/100 compared with conventional method
    • 20 MS/s simultaneous sampling on all channels
    • Safe measurement with all analog inputs isolated
    • Supports 4K monitor to display multi-channel waveforms without overlapping
    • Measure 4 channels with 1 unit (4 ch analog Unit U8975, 4 ch DVM Unit U8991)
    • Generate constant voltage, constant current, and simulated resistance (VIR Generator Unit U8794)