  • Experience precision RF signal analysis on the go with this lightweight, handheld analyzer designed for both lab and field use.

    Key Features:

    • Frequency range: 1MHz to 1.3GHz (PSA1303) or 2.7GHz (PSA2703)
    • RBW: 300Hz to 10MHz
    • -115dBm typical noise floor
    • Dual markers with absolute/difference values
    • AM/FM demodulation in zero span
    • Auto-find & smart marker peak tracking
    • USB for waveform saving and PC connection
    • Live, View, and Reference trace modes
    • 6-hour lithium-ion battery operation
    • Weighs just 0.58 kg
    • Optional U01 Upgrade: Limit lines, data logging, triggering, compensation tables

     

  • High-performance, battery-powered spectrum analyzers ideal for RF engineers and field use.

    Key Features:

    • Frequency range: 10MHz to 3.6GHz or 6.0GHz
    • -120dBm typical noise floor
    • Resolution bandwidths from 300Hz to 10MHz
    • AM/FM audio demodulation with zero span
    • Live, View & Reference traces with markers
    • Smart marker tracking with peak detection
    • USB data logging & real-time PC view
    • Compact, lightweight (0.56 kg) with >3hr battery
    • Optional U02 features: limit lines, OBW, ACPR, AM/FM waveform demodulation

     

  • The Teledyne T3SA Series Spectrum Analyzers deliver high-performance signal analysis from 9 kHz to 3.2 GHz in a compact, easy-to-use design. Ideal for R&D, education, production, and pre-compliance testing, it features a large touchscreen and advanced digital IF technology.

    Key Features:

    • All Digital IF technology10.1”
    • WVGA (1024 x 600) touchscreen display
    • Frequency range from 9 kHz to 3.2 GHz
    • -161 dBm/Hz displayed average noise level (typical)
    • -98 dBc/Hz @ 10 kHz offset phase noise (typical)
    • Total amplitude accuracy < 0.7 dB
    • 1 Hz minimum resolution bandwidth (RBW)
    • Built-in preamplifier for improved sensitivity

    Typical Applications

    ● Research Laboratory
    ● Development Laboratory
    ● Repair and Maintenance
    ● Calibration Laboratory
    ● Automatic Production Test
    ● General bench-top use

  • High-Precision Current Measurement with BNC Connectivity

    • Precision Current Sensing: ±1% accuracy ensures reliable real-time current monitoring.
    • BNC Connector for Seamless Connectivity: Works with oscilloscopes, ADCs, spectrum analyzers, and power analyzers.
    • Clamp-On Design for Non-Intrusive Measurement: Safely monitor live current flow without circuit disruption.
    • 50 Ohm Termination Compatible: Output reduces by half when using a 50Ω termination.
    • High-Voltage Safety Considerations: Conductive case requires adequate insulation for user safety.

     

  • The EME Guard Plus is a lightweight and robust personal protection monitor designed to ensure the safety of workers operating near electromagnetic field (EMF) emitters such as antennas, radars, and base stations. With a frequency range of 1 MHz to 40 GHz, this device continuously monitors and records EMF exposure levels while providing immediate audio, visual, and vibrating alerts when exposure exceeds predefined safety thresholds. Customizable alarm settings and a triaxial isotropic probe ensure accurate and reliable measurements.

     

  • The EME Guard XS Radar is a state-of-the-art RF safety monitor, specifically designed for workers operating near radar transmitters and antennas. With its isotropic tri-axis E-field sensors, this compact device provides continuous EMF monitoring over a frequency range of 1 MHz to 40 GHz, including short pulsed signal detection. Equipped with audio and visual alarms, it alerts users instantly when EMF exposure exceeds predefined safety thresholds, creating a safer working environment for military, aviation, and telecom personnel.

     

  • Solutions For:

    •  Accurate measurement with tri-axis sensors
    • Instant audio and visual alarm
    • Robust, reliable and user-friendly
    • Covers 5G / 6G bands, measuring up to 71 GHz

    User profile:

    • Persons working near antennas including installation and maintenance workers, broadcast, PMR and mobile phone operators or regulatory body employees

    Measurement capabilities:

    • Continuous monitoring of Electromagnetic Field levels with isotropic tri-axis E-field sensors
    • EMF Level indicated by a LED color scale
    • Audio and visual alarms triggered when EMF exceeds the reference level
  •  

    • Reliable and Repeatable solid state signal generation
    • Standard Internal/external pulse modulation
    • USB/Ethernet Control
    • 10 MHz external or internal reference
    • 100 Hz Frequency Resolution
    • Easily portable
    • Sized to fit into a single rack unit for ATE applications

     

  •  

    • Reliable and Repeatable solid state digital attenuation
    • Includes GUI, Windows and Linux SDK, LabVIEW driver
    • Programmable attenuation ramp and fading profiles
    • Operate multiple devices directly from a PC or self-powered hub
    • Easily portable USB powered device
    • USB and Ethernet control interfaces

     

  • HDO4000A oscilloscopes have 4 analog input channels, 12-bit resolution using Teledyne LeCroy’s HD4096 high-definition technology, up to 1 GHz of bandwidth and a compact form factor with a large 12.1” multi-touch display. They are ideal for debug and troubleshooting of power electronics designs, digital power management or power integrity analysis, automotive electronics systems, and deeply embedded or mechatronic designs.

     

  • The WaveSurfer 3000z has a 10.1″ capacitive touch display, the longest memory, and the deepest toolbox – all at an affordable price.

    • HD4096 technology provides 12-bit resolution all the time
    • 2ProBus input supports over 30 probes in 9 product categories
    • 3Long record capture of up to 25 Mpts
    • 412.1” 1280 x 800 HD capacitive touchscreen
    • 5Mixed-signal capability – debug complex embedded designs with integrated 16-channel mixed signal option
    • 6Easy connectivity with 2 USB 3.1 ports
    • 7MAUI with OneTouch user interface for intuitive and efficient operation

     

    • 15.6″ 1920 x 1080 capacitive touchscreen display
    • 24 analog input channels
    • 3ProBus input supports every Teledyne LeCroy probe
    • 4MAUI with OneTouch user interface for intuitive and efficient operation
    • 5Q-Scape multi-tab display architecture
    • 6Up to 250 Mpts of acquisition memory
    • 7HD4096 technology – 12 bits all the time
    • 8Buttons/indicators color-coded to associated waveform on display
    • 9Use cursors and adjust settings without opening a menu
    • 10Mixed Signal capability with 16 integrated digital channels
    • 116 USB 3.1 ports (2 front, 4 side)

     

    • HD4096 technology provides 12-bit resolution up to 8 GHz and 20 GS/s
    • Up to 5 Gpts of acquisition memory enables detailed viewing of long events
    • 15.6” 1900 x 1080 Full HD capacitive touchscreen
    • ProBus2 input supports up to 8 GHz bandwidth while maintaining support for legacy ProBus probes
    • MAUI with OneTouch user interface for intuitive and efficient operation
    • Waveform Control Knobs – Control channel, zoom, math and memory traces with the multiplexed vertical and horizontal knobs
    • Color-coded panel indicators – Trigger, horizontal and vertical indicator colors correspond to the associated waveform on the display
    • Cursor/Adjust Knobs – Enable and position cursors or adjust settings and parameters without opening a menu
    • Mixed Signal Capability – Debug complex embedded designs with integrated 16-channel mixed signal capability
    • Easy connectivity with seven USB 3.1 ports (3 front, 4 side) and UHD (4k) HDMI and DisplayPort outputs

     

    • Eye diagram (a), eye mask failure (b) and IsoBER eye opening analysis (c)
    • Jitter spectrum (a) with noise floor display (b) and inverse FFT of the periodic jitter (c)
    • Data dependent jitter (DDj) plot for each bit in synch with pattern (a) and with histogram (b)
    • Time interval error (TIE) jitter track analysis
    • Jitter histograms (a) with bathtub curves (b) and CDF plot (c)
    • Intersymbol interference (ISI) plots pinpoint bit sequences that have high ISI and are sources of bit errors
    • Jitter measurements table with full details for one or more “lanes” plus reference

     

    • 15.6” 1920 x 1080 capacitive touchscreen display
    • 8 analog input channels
    • ProBus input supports every Teledyne LeCroy probe
    • MAUI with OneTouch user interface for intuitive and efficient operation
    • Q-Scape multi-tab display architecture
    • Up to 5 Gpts of acquisition memory
    • HD4096 technology – 12 bits all the time
    • Buttons/indicators color-coded to associated waveform on display
    • Use cursors and adjust settings without opening a menu
    • Mixed Signal capability with 16 integrated digital channels
    • 6 USB 3.1 ports (2 front, 4 side)
    • HDMI and DisplayPort – supports 4K (4096 x 2304) external monitor
    • Removable SSD (standard)
    • View 16 channels on one display with OscilloSYNC
    • Reference Clock Input/Output for connecting to other equipment
    • USBTMC over USB 3.1 for fast data offload