1 800 665 7301 | info@tmetrix.com

    • 10 kHz – 3 GHz, 40dB Gain, 5dB N.F.
    • Compensation for long cable loss for EMI Measurement
    • Improve system noise floor flatness
    • High EMI performance
    • High linearity LNA for EMI measurement
    • High dynamic range
    • Unconditionally Stable
    • State-of-the-Art Technology

     

    • EMI Measurements:
      • FFT-based dual-channel receiver
      • According to CISPR16-1-1
      • Peak, Quasi-Peak, and Average Detectors
      • Resolution Bandwidth Filters of 200 Hz, 9 kHz, and 120 kHz (CISPR), and 1 kHz and 10 kHz (MIL)
      • The fastest receiver in the market: Line and Neutral measurements with the 3 detectors simultaneously (6 simultaneous measurements)

     

  • Unleash the power of modern, versatile, and sophisticated AC sources with our LSX Series – Programmable AC Power Source. These powerhouses come in single and three-phase options, ranging from 1.5kVA to 6kVA. Equipped with an advanced programmable controller featuring a vivid colour touchscreen interface, the LSX Series is not just cost-effective but also fully programmable for basic frequency conversion, advanced AC power line disturbance tests, and ATE applications.

     

  • Key Features Provide Application Versatility

    • USB, LAN (LXI), IEEE-488.2 and RS-232C with SCPI compatibility
    • Compatible with PPSC Studio graphical user interface
    • LabVIEW for Windows®/LabWindows® drivers
    • Waveform Creation by Harmonic Synthesis
    • Waveform Capture (Voltage and Current)
    • Harmonic Analysis (Voltage and Current)
    • Metering of RMS and Peak Values
    • Continuous Self Calibration (CSC)
    • Line Sync
    • 6:1 Peak Current Capability
    • Low Impedance for EN61000-3-2, 3 Testing
    • Programmable Output Impedance
    • Up to 0-300 VAC Direct Coupled Out
    • 1 Phase / 3 Phase Switch Selectable
    • 15-5000 Hz Full Power Bandwidth
    • Power Levels from 500 VA to 6 kVA standard; 30kVA optional
    • Externally Referenced Meter Calibration
    • CE Safety & EMC and NTRL Safety Mark

     

  • The AZX Series (Regenerative AC / DC Power Source) is a family of high power, single, split and three phase, AC, DC and AC+DC output capable Power Sources with full energy recovery to the AC mains when sinking power from the equipment under test. Available models range from 30 kVA to 440 kVA. Using a modern color touch screen based user interface for ease of use, the AZX Series is cost effective and fully programmable for both basic frequency conversion and advanced AC power line or DC power disturbance test applications requiring up to 1000 Hz fundamental frequency.

    The energy recovery capability allows both sourcing and sinking of current and power up to 100% of rated power. Adding the Load Option (Option L) adds full electronic regenerative AC & DC Load programming capability to the AZX.

     

    • Protocol reports
    • Generation of waveforms with synchronous data acquisition
    • Modular Expandable
    • Individual Waveform Generation
    • Standard Libraries included
    • Unlimited Waveform size
    • 2 different Waveforms synchronously
    • DLL’s for LabView, Vector CANoe / CAPL, C#, C++, ANSI C, Python, etc.
    • Simulation of imported oscilloscope waveform

     

  • BOLAB revolutionizes EV testing with powerful, flexible, and modular HV Electric Vehicle Test Systems. These solutions offer high-speed testing, covering diverse profiles and budgets. Features include a modular design, adaptability, and WaveMaster Software for custom waveforms. Benefit from efficiency, precision, and cost-efficiency in EV testing. Discover the future of high-speed testing with BOLAB’s innovative solutions.

    • Customizable & savable test setups
    • Program & Datalog Storage
    • User Defined Temperature Limits
    • Local & Remote Operations
    • LabView™ drivers
    • IEEE-488, RS232 ports

     

     

    • 20 Amp Operation: Full performance with 20 amp service
    • Automatic Power Reduction: Reduces power usage during idle periods
    • Heat Only Mode: Reduces power usage when cold temperatures are not used
    • WhisperStream Technology: quieter, smooth-sounding operation, 56 dBA
    • Frost Free Test Environment: dry air purge for tester interface, prevents condensation:
      0.5 to 3scfm (0.25 to 1.5 l/s)
    • Heated Defrost: quickly removes moisture buildup from internal chiller
    • DUT Temperature Control : Proprietary control algorithm enables DUT temperature to be directly controlled
    • Transition Rate*
      -55 to +125°C, approx. 10 seconds
      125 to -55°C, approx. 10 seconds
    • System Airflow Output*
      4 to 18scfm (1.9 to 8.5 l/s) Continuous
    • Temperature Range*
      -80 to +225°C (60Hz) No LN2 or LCO2 Required

     

    • High reliability thermal cycling without thermoelectric modules
    • Temperature range: -65 to 175°C
    • Cooling power:
      • 40W at -40°C for lower power devices
      • 55W at -55°C and 120W at -40°C.
    • Transition rate: up to <35 sec over 25 to -40°C
    • Easy and secure thermal connection to in-circuit or test socked DUT
    • Touch-screen controller: user-programmable temperatures, graphing, data logging
    • Communications options: Ethernet, USB, IEEE, RS232

     

  • -60° to +200°C

    • Economy model with high thermal capacity
    • Precise temperatures with fast transitions from -60 to 200°C
    • No annual leak testing required per EU 517/2014 F-Gas Regulation
    • Effective testing and conditioning of electronic components, boards, and modules
    • Available for 50 and 60Hz operation
    • No need for Liquid Nitrogen (LN2) or Liquid Carbon Dioxide (LCO2)
    • Remote communications and set up and touch screen operation
    • User Defined Temperature Limits

     

     

  • Key Performance Capabilities:

    • Slew rates up to 60 V/µsec.
    • Up to 240A DC at +50VDC or –50VDC (4301-240 configuration).
    • Can provide pulses of up to 800 amps at voltages of up to ±100V (4301-240 configuration).
    • Adjustable compensation allows the system to maintain a 50V/2 µsec rise-time over a wide range of current outputs.

     

  • Key Performance Capabilities:

    • Bandwidth: DC to 50 kHz
    • Voltage: 0 to 250 VRMS; 0 to 350 VDC
    • Current: 100 to 500 ARMS
    • Distortion: 0.1%
    • Power: 4 kW to 20 kW*Power levels up to 5X rated power when driving reactive loads
    • High power efficiency and density

    *Models available with output from 4 kW to 20 kW (capable of up to 125 kVA).

     

  • Key Performance Capabilities:

    • 4-Quadrant – Can source and sink current
    • ±80V – DC supply for 12V to 48V systems; meets 80V surge requirements
    • 300 kHz Sine – DC ripple tests for all major standards
    • 3µs Rise Time – Exceeds surge and dropout slew rate requirements
    • 3mΩ DC Source Impedance – Out-performs ISO 7637-2 requirements
    • Supports ground reference and supply offset testing required for ISO 16750-2 Sect. 4.8 and other similar standards

     

  • Key Performance Capabilities:

    • Up to 900 watts RMS power output (7136 model)
    • Small signal response up to 400 kHz
    • User-adjustable precision DC offset
    • User-adjustable current limit: 1A to 25A
    • 4-quadrant operation
    • AC/DC coupled

     

  • Key Performance Capabilities:

    • Up to 900 watts RMS power output (7136 model)
    • Small signal response up to 400 kHz
    • User-adjustable precision DC offset
    • User-adjustable current limit: 1A to 25A
    • 4-quadrant operation
    • AC/DC coupled