1 800 665 7301 | info@tmetrix.com

  • with analogue and digital control, USB, RS232, LAN (LXI) and GPIB

    • Versatile solution for direct testing of dc power sources and PFCs
    • Constant current, resistance, conductance and power modes
    • Wide voltage and current range, 10 to 500V and 0 to 16A
    • 400 watts continuous dissipation at 28°C (360W at 40°C)
    • High resolution and accuracy for level setting
    • Built-in transient generator with variable slew
    • Current monitor output for waveform viewing
    • Variable drop-out voltage for battery testing
    • High resolution backlit graphic LCD with soft key control
    • Analogue remote control of levels and TTL control of on/off and transient switching
    • Front and rear input terminals
    • Load inputs rated to CAT II (300V)
    • Full bus control via USB, RS232, GPIB and LXI compliant LAN interfaces

     

    • Multiple ranges on each output for wider voltage/current choice
    • Four independent 105W full performance outputs
    • Instant individual on/off control plus sequencable multi on/off
    • Simultaneous display of meters and settings for all outputs
    • Up to 250 settings memories for individual or multiple outputs
    • Instant access to voltage/current setting for any output
    • USB, RS-232, LXI compliant LAN, and GPIB* interfaces (P versions)
    • USB, RS-232, LXI compliant LAN, and GPIB* interfaces (P versions)
      Duplicate power and sense terminals at rear (P versions)

     

    • Frequency up to 160MHz, 15 digits or 1µHz resolution
    • Wideband noise generator | high resolution pulse generator
    • Arbitrary waveforms up to 16bits at 800MS/s
    • Comprehensive internal/external digital and analog modulations
    • Two identical channels with phase control, coupling and tracking
    • USB and LXI compliant LAN interfaces, plus optional GPIB interface

     

  • Pulse and Universal Generator with 25 or 50MHz models, single or dual channel

    TGP3100 Series

     

    • Arbitrary waveforms at 800MS/s sampling rate and 16-bit vertical resolution
    • Extensive internal/external modulation of all waveform types
    • Linear and logarithmic sweeps of all waveform types
    • Front panel mounted USB Flash drive interface
    • GPIB (option), USB and LXI compliant LAN interfaces
    • Triggered (burst count) or gated operation using internal or external trigger sources

     

    • Arbitrary waveforms at 800MS/s sampling rate and 16-bit vertical resolution
    • Extensive internal/external modulation of all waveform types
    • Linear and logarithmic sweeps of all waveform types
    • Front panel mounted USB Flash drive interface
    • GPIB (option), USB and LXI compliant LAN interfaces
    • Triggered (burst count) or gated operation using internal or external trigger sources

     

    • Arbitrary waveforms at 800MS/s sampling rate and 16-bit vertical resolution
    • Extensive internal/external modulation of all waveform types
    • Linear and logarithmic sweeps of all waveform types
    • Front panel mounted USB Flash drive interface
    • GPIB (option), USB and LXI compliant LAN interfaces
    • Triggered (burst count) or gated operation using internal or external trigger sources

     

    • Arbitrary waveforms at 800MS/s sampling rate and 16-bit vertical resolution
    • Extensive internal/external modulation of all waveform types
    • Linear and logarithmic sweeps of all waveform types
    • Front panel mounted USB Flash drive interface
    • GPIB (option), USB and LXI compliant LAN interfaces
    • Triggered (burst count) or gated operation using internal or external trigger sources

     

    • Sine frequency up to 240MHz with 1µHz resolution
    • Up to 100MHz high resolution pulse generator
    • Arbitrary waveforms up to 16bits at 800MSa/s
    • Wideband noise generator

     

    • Proven member of a modular Power Module family, more than 800 units are in service
    • Precision-regulated Bi-Polar output provides up to +12 to -12 Amps for Magnet loads.
    • Smooth operation through zero amps output current, no “Crossover” problems.
    • All 2510 MCOR12 Power Modules are identical and interchangeable.
    • Has two high-precision measurements of output current;
      • one is used to close the regulation control loop,
      • provides an independent monitoring signal to the Crate Interface Card.
    • Fault sensing circuitry in the module sets a Fault Latch which inhibits the output.
    • A (momentary) Sync input signal inhibits MOSFET switching when it is active (high);
      • this eliminate switching noise .
      • reduces power line noise during sensitive analog signal measurements.

     

    • Proven member of a modular Power Module family, more than 800 units are in service
    • Precision-regulated Bi-Polar output provides up to +30 to -30 Amps for Magnet loads.
    • Smooth operation through zero amps output current, no “Crossover” problems.
    • All 2510R30 MCOR30 Power Modules are identical and interchangeable
      • Programming Card is plugged into the replacement module.
    • Each channel has a critically-damped, LC noise filter with a cut-off frequency of about 8 kHz.
    • A 16-pin front panel diagnostics connector taps onto major circuit nodes which enables quick “inthe-crate” fault evaluation

     

    • 2U Chassis – 19″ rack mount 3.48” Height, 9.60” Depth and Weight 6lb.
    • Power 120V AC 60Hz
    • Washable front removable air filter
    • Ball Bearing AC fans provide 330 CFM
    • Dual plenum design
    • Cooling for 160mm,220mm depth modules
    • Diverts lower warmed air to rear of Cabinet
    • RM option diverts lower air to front of Cabinet

     

    • accommodate these control schemes
    • total control system interface on a single VME-standard card
    • occupies the left-most slot of the crate
    • monitoring voltage reference inputs, output voltages and fault conditions
    • standard VMEbus-compatible 6U by 220 mm board installed
    • Eurocard crate
    • Two 96-pin I/O connectors

     

  • MCOR Modules

    MCOR 2/6/9/12

    Each module can be customized to provide maximum outputs of 2 amps, 6 amps, 9 amps, and 12 amps. Up to 16 of these can fit in a single 6U VME style crate.

    MCOR 30

    Each module can provide a maximum output 30 amps. Up to 8 of these can fit in a single 6U VME style crate.

  • The Hi-Techniques FreeStyle series of Data Acquisition Systems is a versatile, capable solution for mobile and rugged data acquisition applications. FreeStyle was designed from the ground up to make data acquisition as fast and as easy as possible. Just grab your FreeStyle and your computer and head out to the test site.

    Flexibility by Design