1 800 665 7301 | info@tmetrix.com

  • Teledyne Test Tools T3DAQ1-16 is a powerful 16-channel Data Acquisition Unit, perfect for R&D and production testing environments.

    Key Features:

    • 16-channel input (12 multi-purpose + 4 current)
    • Built on a 6½ digit digital multimeter platform
    • Wide range of electrical measurements: voltage, current, resistance, capacitance, frequency
    • True-RMS accuracy for AC voltage and current
    • Large 4.3″ TFT LCD with dual-display views
    • Display modes: Histogram, Trend, Bar Graph, Statistics, or Number
    • USB Host, USB Device, and LAN connectivity
    • Cold terminal thermocouple compensation
    • Softkey interface for intuitive navigation
  • A high-performance 20MHz DDS function generator offering precise waveform control, high spectral purity, and flexible remote interfacing.

    Key Features:

    • Frequency range: 0.001Hz to 20MHz
    • High resolution: 6 digits or 1mHz
    • Frequency stability: ±1ppm, accuracy: ±10ppm
    • Ultra-low distortion sine waves with high spectral purity
    • Internal linear/log sweep with phase continuity
    • Built-in AM, FSK, gated, and tone-switching modes
    • Output: 5mV to 20V pk-pk from 50Ω or 600Ω
    • Store and recall multiple instrument set-ups
    • USB and RS232 interfaces for remote programming

     

  • A high-purity 20MHz DDS function generator designed for engineers requiring precision signal output, advanced modulation, and digital control.

    Key Features:

    • Frequency range: 0.001Hz to 20MHz
    • High resolution: 6 digits or 1mHz
    • Excellent stability (1ppm) and 10ppm one-year accuracy
    • Digital control for phase-continuous sweep (linear or logarithmic)
    • Output range: 5mV to 20V peak-to-peak from 50 or 600 Ohms
    • Low distortion sine wave with high spectral purity
    • Built-in modulation: AM, FSK, gated mode, tone switching
    • Store and recall multiple instrument setups
    • USB and RS232 interfaces for remote control

     

  • High-performance dual-channel function and arbitrary waveform generator with up to 240 MHz output for advanced test and signal needs.

    Key Features:

    • Frequency range from 40 MHz to 240 MHz
    • Dual independent or coupled full-performance channels
    • Precise phase control: 0.001° resolution
    • Arbitrary waveform support up to 800 MS/s
    • Replay rates up to 80 MHz
    • Wide range of built-in and user-defined waveforms
    • Pulse generation up to 100 MHz, low jitter
    • Internal/external modulation, sweep, gated, and burst modes
    • USB, LAN (LXI compliant), and optional GPIB
    • PC software for waveform generation and editing

     

  • Key Features:

    • Single output up to 360W: Choose between 18V/20A or 35V/10A
    • Mixed-mode regulation for high accuracy and low noise
    • Fanless convection cooling for completely silent operation
    • Bench or rack mountable, front and rear terminals
    • OVP trip, high-resolution settings, and remote sense terminals
    • P models offer USB, RS232, LAN interfaces (GPIB optional)
    • Rotary, keypad, and step control for voltage and current
    • Non-volatile memory for storing up to 25 user presets
    • Seamless integration with Test Bridge software and automation systems

     

  • Key Features:

    • Free-standing turntable designed for electromagnetic absorption chambers
    • 0.3 m diameter with 50 kg load capacity
    • Height: 190 mm, made of rigid PVC skin-foam sheets
    • Rotating speed adjustable from 0.1 rpm to 2.5 rpm
    • High positioning accuracy of ±0.5°
    • Rotation angle: -200° to 400° with synchronous servo motor
    • LAN (TCP/IP) control option via FCU3.0 or NCD Controller
    • Central 50 mm opening for power supply insertion
    • Interference suppression: 20 dB under DIN EN 55011:2018-05 class B
    • Ideal for automotive, telecom, medical, and industrial EMC testing

     

  • The TT 1.0 PF Turn Table is a precision turntable designed for EMC and RF testing in anechoic and electromagnetic absorption chambers.

    Key Features:

    • Diameter: 1.0 m; height: 190 mm
    • Load capacity up to 100 kg
    • Free-standing design for chamber floor installation
    • Adjustable rotation speed: 0.1–2.5 rpm
    • Positioning accuracy: ±0.5°
    • Rotating angle range: -200° to 400°
    • Central 50 mm opening for power supply connections
    • Controlled via LAN (TCP/IP) with FCU3.0 or NCD Controllers
    • Durable PVC integral skin-foam cover plate
    • Synchronous servo motor with toothed belt and worm gear drive

     

  • The T3VNA Series from Teledyne Test Tools is a powerful, compact solution for engineers who demand precision and versatility in RF and spectrum analysis.

    Key Features:

    • Vector Network Analysis from 10 MHz to 3.2 GHz
    • Spectrum Analysis from 9 kHz to 3.2 GHz
    • All-digital IF technology for clean signal processing
    • Built-in tracking generator (up to 1.5 GHz)
    • Advanced features like Distance-to-Fault, OBW, ACPR
    • -156 dBm/Hz typical displayed average noise level
    • -98 dBc/Hz @ 10 kHz offset phase noise
    • 1 Hz minimum RBW for high-resolution measurements
    • 10.1″ WVGA display for smooth operation
    • High accuracy with <1.2 dB amplitude error
  • VRC Reverb Tent Chamber is a flexible, modular electromagnetic test facility designed for immunity and emission testing with high efficiency and portability.

    Key Features:

    • Flexible metallic fabric tent construction
    • Wide frequency range (up to 18 GHz)
    • Mechanical vibration walls (5–20 Hz) for uniform reverberation
    • Faster test throughput compared to traditional methods
    • Modular, customizable dimensions for large or small DUTs
    • Compliant with IEC 61000-4-21 and MIL-STD-461 standards
    • Easy to assemble, disassemble, and transport
    • Optional accessories: antennas, filters, control rooms

     

  • Compact yet powerful, the WA301 extends the output of your function generator with clean, reliable amplification up to 30V peak-to-peak.

    Key Features:

    • 30V peak-to-peak output swing
    • DC to 1MHz wide bandwidth
    • High impedance input with 0dB to +20dB variable gain
    • 50 Ohm and 600 Ohm outputs
    • Switchable 20dB output attenuator
    • Fully protected output for safe use
    • Ideal for extending function generator output capability

     

  • The CDG 7000 is a new test generator for all standards on immunity to conducted disturbances induced by high-frequency fields – including BCI tests (ISO 11452-4). One of the very few combined IEC 61000-4-6 test systems that contain the RF signal generator, an RF power amplifier, a 3-channel RF voltmeter, and a directional coupler at a very affordable price. IEC 60601-1-2 calling out IEC 61000-4-39 magnetic immunity for close proximity testing requirements can also now be met with the 10 kHz unit.

    • Frequency Range:
      • 10 kHz – 30 MHz Conducted
      • 5 MHz – 1GHz Radiated
    • Frequency step:
      • 10/500 kHz switchable CE
      • 5/10 MHz switchable RE
    • Includes: Generator, antenna, charger, wood case

     

    • 10 kHz – 3 GHz, 40dB Gain, 5dB N.F.
    • Compensation for long cable loss for EMI Measurement
    • Improve system noise floor flatness
    • High EMI performance
    • High linearity LNA for EMI measurement
    • High dynamic range
    • Unconditionally Stable
    • State-of-the-Art Technology

     

    • EMI Measurements:
      • FFT-based dual-channel receiver
      • According to CISPR16-1-1
      • Peak, Quasi-Peak, and Average Detectors
      • Resolution Bandwidth Filters of 200 Hz, 9 kHz, and 120 kHz (CISPR), and 1 kHz and 10 kHz (MIL)
      • The fastest receiver in the market: Line and Neutral measurements with the 3 detectors simultaneously (6 simultaneous measurements)

     

  • The EMI 64k software allows to embed the TDEMI systems in a fully automated test environment.

    • Full automation of EMI testing according to all commercial and military standards
    • Automated control of turntable, antenna and other equipment
    • Height and Angular Scan
    • Procedures according to standards as well as customized procedures
    • Reducing the cost for EMC and communication testing and certification by tailored packages

     

  • The measurement system for all emission measurments in the frequency range 1 Hz – 44 GHz.

    • Frequency Range  1 Hz – 30MHz, 1GHz, 3GHz, 6GHz, 9GHz, 18GHz, 26GHz, 40 GHz and 44GHz
    • 225 MHz Real-time Analysis Bandwidth
    • Weighted Real-time Spectrogram up to 44 GHz
    • CISPR Bandwidths 200 Hz, 9 kHz, 120 kHz, 1 MHz
    • MIL/DO Bandwidths 10 Hz, 100 Hz, 1 kHz, 10 kHz, 100 kHz, 1 MHz