1 800 665 7301 | info@tmetrix.com

  • High-performance power simulator designed for advanced EMC and automotive voltage testing.

    Key Features:

    • Supports 12V, 24V, 42V, 48V, and 70V automotive systems
    • Battery simulation with up to 220A current
    • Fast voltage rise time up to 100V/µs
    • ISO 7637-2 and ISO 16750-2 compliant
    • Integrated Impulse Recording Function (IRF)
    • Full remote control via CAR-Remote software
    • Ethernet interface and built-in safety interlock
    • Cooling via fans and heat sink for reliable operation
    • Compact 19-inch rackmount desktop system (60 kg)
    • Overvoltage and thermal protection included

     

  • A high-purity 20MHz DDS function generator designed for engineers requiring precision signal output, advanced modulation, and digital control.

    Key Features:

    • Frequency range: 0.001Hz to 20MHz
    • High resolution: 6 digits or 1mHz
    • Excellent stability (1ppm) and 10ppm one-year accuracy
    • Digital control for phase-continuous sweep (linear or logarithmic)
    • Output range: 5mV to 20V peak-to-peak from 50 or 600 Ohms
    • Low distortion sine wave with high spectral purity
    • Built-in modulation: AM, FSK, gated mode, tone switching
    • Store and recall multiple instrument setups
    • USB and RS232 interfaces for remote control

     

  • A high-performance 20MHz DDS function generator offering precise waveform control, high spectral purity, and flexible remote interfacing.

    Key Features:

    • Frequency range: 0.001Hz to 20MHz
    • High resolution: 6 digits or 1mHz
    • Frequency stability: ±1ppm, accuracy: ±10ppm
    • Ultra-low distortion sine waves with high spectral purity
    • Internal linear/log sweep with phase continuity
    • Built-in AM, FSK, gated, and tone-switching modes
    • Output: 5mV to 20V pk-pk from 50Ω or 600Ω
    • Store and recall multiple instrument set-ups
    • USB and RS232 interfaces for remote programming

     

  • High-performance dual-channel function and arbitrary waveform generator with up to 240 MHz output for advanced test and signal needs.

    Key Features:

    • Frequency range from 40 MHz to 240 MHz
    • Dual independent or coupled full-performance channels
    • Precise phase control: 0.001° resolution
    • Arbitrary waveform support up to 800 MS/s
    • Replay rates up to 80 MHz
    • Wide range of built-in and user-defined waveforms
    • Pulse generation up to 100 MHz, low jitter
    • Internal/external modulation, sweep, gated, and burst modes
    • USB, LAN (LXI compliant), and optional GPIB
    • PC software for waveform generation and editing

     

  • Key Features:

    • Single output up to 360W: Choose between 18V/20A or 35V/10A
    • Mixed-mode regulation for high accuracy and low noise
    • Fanless convection cooling for completely silent operation
    • Bench or rack mountable, front and rear terminals
    • OVP trip, high-resolution settings, and remote sense terminals
    • P models offer USB, RS232, LAN interfaces (GPIB optional)
    • Rotary, keypad, and step control for voltage and current
    • Non-volatile memory for storing up to 25 user presets
    • Seamless integration with Test Bridge software and automation systems

     

    • Versatile Current Sensing: Accurately measure small and large currents, from sub-milliamp levels to thousands of amps.
    • High-Speed Pulse Monitoring: Patented distributed termination technology enables ultra-fast rise time measurement (as short as 2ns).
    • Enhanced Noise Immunity & Safety: Double shielding minimizes external noise, making these monitors ideal for high-voltage applications.
    • Robust Construction: Sealed models are suitable for high-voltage insulating oil or vacuum environments.
    • Broad Compatibility: Works with oscilloscopes, spectrum analyzers, power analyzers, digital voltmeters, ADCs, and more.

     

  • High-Precision Current Measurement with BNC Connectivity

    • Precision Current Sensing: ±1% accuracy ensures reliable real-time current monitoring.
    • BNC Connector for Seamless Connectivity: Works with oscilloscopes, ADCs, spectrum analyzers, and power analyzers.
    • Clamp-On Design for Non-Intrusive Measurement: Safely monitor live current flow without circuit disruption.
    • 50 Ohm Termination Compatible: Output reduces by half when using a 50Ω termination.
    • High-Voltage Safety Considerations: Conductive case requires adequate insulation for user safety.

     

  • High-Precision Current Sensing with BNC Connectivity

    • High-Precision Measurement: ±1% accuracy for reliable current sensing.
    • Customizable Configurations: Designed to meet specific user requirements for precision measurement.
    • BNC Connector for Easy Integration: Works with oscilloscopes, ADCs, spectrum analyzers, and power analyzers.
    • Non-Insulated Conductive Case: Proper insulation must be provided on the monitored conductor.
    • 50 Ohm Termination Compatibility: Using a 50Ω termination reduces the output to half.

     

  • High-Precision Voltage Measurement Up to 500kV

    • High-Voltage Measurement Capability: Supports up to 500kV in insulating oil and customizable calibration for air use.
    • Precision Division Ratios: Models with 5000:1, 10,000:1, and custom ratios, ensuring reliable voltage scaling.
    • Temperature-Compensated Accuracy: ±1% over 20°C to 80°C, providing stable voltage readings.
    • Robust Design for Harsh Environments: Sealed for high-voltage insulating oil use, with custom air calibration available.
    • Safe Operation with Ground Loop Control: The outer conductor is isolated from the case, allowing controlled grounding connections.

     

  • Precision Pulse Output Up to 500kV

    • Wide Voltage Range: Supports 100kV to 500kV pulse outputs for high-energy applications.
    • Fast Pulse Transmission: Pulse durations from 0.25 to 50 microseconds, ensuring efficient energy transfer.
    • Insulating Oil Immersion: Open-construction design for operation in high-voltage insulating oil, reducing breakdown risks.
    • Advanced Overvoltage Protection: Designed with built-in safety factors (50-100%) to prevent damage from overvoltages.
    • Reliable Flashover Protection: Corona ring-to-core insulation prevents damage from accidental flashovers.

     

  • The CDG 7000 is a new test generator for all standards on immunity to conducted disturbances induced by high-frequency fields – including BCI tests (ISO 11452-4). One of the very few combined IEC 61000-4-6 test systems that contain the RF signal generator, an RF power amplifier, a 3-channel RF voltmeter, and a directional coupler at a very affordable price. IEC 60601-1-2 calling out IEC 61000-4-39 magnetic immunity for close proximity testing requirements can also now be met with the 10 kHz unit.

    • Frequency Range:
      • 10 kHz – 30 MHz Conducted
      • 5 MHz – 1GHz Radiated
    • Frequency step:
      • 10/500 kHz switchable CE
      • 5/10 MHz switchable RE
    • Includes: Generator, antenna, charger, wood case

     

    • 10 kHz – 3 GHz, 40dB Gain, 5dB N.F.
    • Compensation for long cable loss for EMI Measurement
    • Improve system noise floor flatness
    • High EMI performance
    • High linearity LNA for EMI measurement
    • High dynamic range
    • Unconditionally Stable
    • State-of-the-Art Technology

     

  • The EME Guard Plus is a lightweight and robust personal protection monitor designed to ensure the safety of workers operating near electromagnetic field (EMF) emitters such as antennas, radars, and base stations. With a frequency range of 1 MHz to 40 GHz, this device continuously monitors and records EMF exposure levels while providing immediate audio, visual, and vibrating alerts when exposure exceeds predefined safety thresholds. Customizable alarm settings and a triaxial isotropic probe ensure accurate and reliable measurements.

     

  • The EME Guard XS Radar is a state-of-the-art RF safety monitor, specifically designed for workers operating near radar transmitters and antennas. With its isotropic tri-axis E-field sensors, this compact device provides continuous EMF monitoring over a frequency range of 1 MHz to 40 GHz, including short pulsed signal detection. Equipped with audio and visual alarms, it alerts users instantly when EMF exposure exceeds predefined safety thresholds, creating a safer working environment for military, aviation, and telecom personnel.

     

  • Solutions For:

    •  Accurate measurement with tri-axis sensors
    • Instant audio and visual alarm
    • Robust, reliable and user-friendly
    • Covers 5G / 6G bands, measuring up to 71 GHz

    User profile:

    • Persons working near antennas including installation and maintenance workers, broadcast, PMR and mobile phone operators or regulatory body employees

    Measurement capabilities:

    • Continuous monitoring of Electromagnetic Field levels with isotropic tri-axis E-field sensors
    • EMF Level indicated by a LED color scale
    • Audio and visual alarms triggered when EMF exceeds the reference level