1 800 665 7301 | info@tmetrix.com

  • Compact, versatile, and efficient, the FX Series is ideal for test labs, R&D, and educational use.

    Key Features:

    • PowerFlex autoranging outputs (up to 105W per channel)
    • Dual or triple output models (210W or 246W total)
    • SELV compliant and high safety design
    • Rotary, touch, and USB control options
    • Low ripple noise (<2mV), high resolution (1mV/1mA)
    • Voltage tracking and simultaneous V/I control
    • Remote USB interface with SCPI protocol
    • 25 user-defined memory presets
    • Switchable remote sense & intelligent cooling
    • Includes Test Bridge software for logging & automation

     

  • A turnkey solution for harmonics and flicker compliance, this system delivers powerful, efficient, and automated testing for today’s high-power demands.

    Key Features:

    • Fully compliant with IEC/EN 61000-3-2, -3-3, -3-11, and -3-12
    • High-power testing up to 75 A and 50 kVA
    • Regenerative AC power supply with energy recovery
    • Programmable simulation: voltage, frequency, harmonics, interharmonics
    • Precision impedance network for accurate flicker measurements
    • Advanced power analyzer with harmonic and flicker metering
    • Preloaded test sequences with automated software control
    • Expandable to include dips, swells, and short interruptions

     

    • Current measurement from insulated probing of conductor
    • Suitable for observation and measurement of current in PCB tracks, component leads and ground planes
    • Wide dynamic range of 10mA to 20A peak to peak
    • Wide bandwidth of DC to 5MHz
    • Low noise figure equivalent to <6mA rms at full B/W
    • Safety rated to 300V Cat II (600V Cat 1)
    • Suitable for connection to any oscilloscope
    • High accuracy general purpose H-field probe
    • Converts to ‘closed magnetic circuit’ current probe

     

  • A compact, high-performance power supply for automotive EMC and battery voltage simulation.

    Key Features:

    • Battery simulator for 12V, 24V, 42V, and 48V systems
    • Output: 0–66V / 0–55A (max)
    • Fast voltage rise time up to 100V/µs
    • ISO 7637-2 and ISO 16750-2 compliant
    • Remote control via CAR-Remote Software
    • Impulse Recording Function (IRF) included
    • Compact 19-inch desktop form (15 kg only)
    • Overvoltage and thermal protection
    • Slew rate: 10V/µs with fan cooling system
    • Compatible with HILO CAR-SYS test systems

     

  • High-performance power simulator designed for advanced EMC and automotive voltage testing.

    Key Features:

    • Supports 12V, 24V, 42V, 48V, and 70V automotive systems
    • Battery simulation with up to 220A current
    • Fast voltage rise time up to 100V/µs
    • ISO 7637-2 and ISO 16750-2 compliant
    • Integrated Impulse Recording Function (IRF)
    • Full remote control via CAR-Remote software
    • Ethernet interface and built-in safety interlock
    • Cooling via fans and heat sink for reliable operation
    • Compact 19-inch rackmount desktop system (60 kg)
    • Overvoltage and thermal protection included

     

  • Experience precision RF signal analysis on the go with this lightweight, handheld analyzer designed for both lab and field use.

    Key Features:

    • Frequency range: 1MHz to 1.3GHz (PSA1303) or 2.7GHz (PSA2703)
    • RBW: 300Hz to 10MHz
    • -115dBm typical noise floor
    • Dual markers with absolute/difference values
    • AM/FM demodulation in zero span
    • Auto-find & smart marker peak tracking
    • USB for waveform saving and PC connection
    • Live, View, and Reference trace modes
    • 6-hour lithium-ion battery operation
    • Weighs just 0.58 kg
    • Optional U01 Upgrade: Limit lines, data logging, triggering, compensation tables

     

  • High-performance, battery-powered spectrum analyzers ideal for RF engineers and field use.

    Key Features:

    • Frequency range: 10MHz to 3.6GHz or 6.0GHz
    • -120dBm typical noise floor
    • Resolution bandwidths from 300Hz to 10MHz
    • AM/FM audio demodulation with zero span
    • Live, View & Reference traces with markers
    • Smart marker tracking with peak detection
    • USB data logging & real-time PC view
    • Compact, lightweight (0.56 kg) with >3hr battery
    • Optional U02 features: limit lines, OBW, ACPR, AM/FM waveform demodulation

     

  • A high-purity 20MHz DDS function generator designed for engineers requiring precision signal output, advanced modulation, and digital control.

    Key Features:

    • Frequency range: 0.001Hz to 20MHz
    • High resolution: 6 digits or 1mHz
    • Excellent stability (1ppm) and 10ppm one-year accuracy
    • Digital control for phase-continuous sweep (linear or logarithmic)
    • Output range: 5mV to 20V peak-to-peak from 50 or 600 Ohms
    • Low distortion sine wave with high spectral purity
    • Built-in modulation: AM, FSK, gated mode, tone switching
    • Store and recall multiple instrument setups
    • USB and RS232 interfaces for remote control

     

  • A high-performance 20MHz DDS function generator offering precise waveform control, high spectral purity, and flexible remote interfacing.

    Key Features:

    • Frequency range: 0.001Hz to 20MHz
    • High resolution: 6 digits or 1mHz
    • Frequency stability: ±1ppm, accuracy: ±10ppm
    • Ultra-low distortion sine waves with high spectral purity
    • Internal linear/log sweep with phase continuity
    • Built-in AM, FSK, gated, and tone-switching modes
    • Output: 5mV to 20V pk-pk from 50Ω or 600Ω
    • Store and recall multiple instrument set-ups
    • USB and RS232 interfaces for remote programming

     

  • High-performance dual-channel function and arbitrary waveform generator with up to 240 MHz output for advanced test and signal needs.

    Key Features:

    • Frequency range from 40 MHz to 240 MHz
    • Dual independent or coupled full-performance channels
    • Precise phase control: 0.001° resolution
    • Arbitrary waveform support up to 800 MS/s
    • Replay rates up to 80 MHz
    • Wide range of built-in and user-defined waveforms
    • Pulse generation up to 100 MHz, low jitter
    • Internal/external modulation, sweep, gated, and burst modes
    • USB, LAN (LXI compliant), and optional GPIB
    • PC software for waveform generation and editing

     

  • Key Features:

    • Single output up to 360W: Choose between 18V/20A or 35V/10A
    • Mixed-mode regulation for high accuracy and low noise
    • Fanless convection cooling for completely silent operation
    • Bench or rack mountable, front and rear terminals
    • OVP trip, high-resolution settings, and remote sense terminals
    • P models offer USB, RS232, LAN interfaces (GPIB optional)
    • Rotary, keypad, and step control for voltage and current
    • Non-volatile memory for storing up to 25 user presets
    • Seamless integration with Test Bridge software and automation systems

     

  • The CDG 7000 is a new test generator for all standards on immunity to conducted disturbances induced by high-frequency fields – including BCI tests (ISO 11452-4). One of the very few combined IEC 61000-4-6 test systems that contain the RF signal generator, an RF power amplifier, a 3-channel RF voltmeter, and a directional coupler at a very affordable price. IEC 60601-1-2 calling out IEC 61000-4-39 magnetic immunity for close proximity testing requirements can also now be met with the 10 kHz unit.

    • Frequency Range:
      • 10 kHz – 30 MHz Conducted
      • 5 MHz – 1GHz Radiated
    • Frequency step:
      • 10/500 kHz switchable CE
      • 5/10 MHz switchable RE
    • Includes: Generator, antenna, charger, wood case

     

    • 10 kHz – 3 GHz, 40dB Gain, 5dB N.F.
    • Compensation for long cable loss for EMI Measurement
    • Improve system noise floor flatness
    • High EMI performance
    • High linearity LNA for EMI measurement
    • High dynamic range
    • Unconditionally Stable
    • State-of-the-Art Technology

     

    • EMI Measurements:
      • FFT-based dual-channel receiver
      • According to CISPR16-1-1
      • Peak, Quasi-Peak, and Average Detectors
      • Resolution Bandwidth Filters of 200 Hz, 9 kHz, and 120 kHz (CISPR), and 1 kHz and 10 kHz (MIL)
      • The fastest receiver in the market: Line and Neutral measurements with the 3 detectors simultaneously (6 simultaneous measurements)