1 800 665 7301 | info@tmetrix.com

  • The ECO-710E/810E ThermoStream® systems are eco-friendly temperature forcing solutions designed for precise electronic testing, delivering fast temperature transitions with quiet, energy-efficient operation.

    Key Features:

    • Wide temperature range: -80°C to +225°C
    • Eco-friendly design compliant with EU 517/2014 (no annual leak testing)
    • Quiet operation at just 56 dBA
    • Energy-efficient performance on a 20-amp circuit
    • Rapid temperature transitions for consistent results
    • Touchscreen controls with embedded software (no Windows® OS)
    • No need for LN2 or LCO2 cooling agents
    • Remote setup and communication capabilities
    • Ideal for 24/7/365 lab or production use

     

  • EMC001330SE | 10 kHz – 3 GHz | 30 dB Gain | Low Noise Preamplifier

    Key Features:

    • Wide frequency range: 10 kHz to 3 GHz
    • High gain: 30 dB minimum with ±1.5 dB flatness
    • Low noise figure: ≤ 5 dB for precise EMI measurements
    • Ideal for compensating long cable loss
    • High linearity and dynamic range
    • Unconditionally stable, reliable performance
    • Compact, portable, and robust design
    • Compatible with major EMI test standards (CISPR, MIL-STD, ANSI)
    • 110–240V AC universal power support
    • Includes AC to DC inverter and N-type connectors

     

  • EMC03640A Low Noise Preamplifier – 30 MHz to 6 GHz

    Key Features:

    • Wide frequency range: 30 MHz to 6 GHz
    • High gain: 40 dB minimum with ±2.5 dB flatness
    • Low noise figure: ≤ 2.5 dB
    • High EMI performance with excellent linearity
    • Compensates for long cable loss in EMI measurements
    • Improves system noise floor flatness
    • Unconditionally stable with high dynamic range
    • State-of-the-art technology for compliance testing
    • Meets major EMI/EMC standards (ANSI, CISPR, MIL-STD)
    • Compact and robust design with AC mains power input

  • The EMC051835SE is a high-performance preamplifier designed to deliver exceptional gain and EMI measurement accuracy across a wide frequency range.

    Key Features:

    • Wide frequency coverage: 500 MHz to 18 GHz
    • 35 dB minimum gain with ±2.5 dB flatness
    • Low noise figure of 3 dB for improved sensitivity
    • High linearity LNA for EMI testing applications
    • Enhances system noise floor flatness
    • Compensates for long cable losses in EMI measurements
    • Built-in AC input power with grounding detect circuit
    • Durable, compact design with SMA female connectors
    • Unconditionally stable performance

     

  • EMC1150 Low Noise Preamplifier (9 kHz – 1 GHz, 50 dB Gain)

    Key Features:

    • Wide frequency range: 9 kHz to 1 GHz
    • High gain performance: 50 dB minimum
    • Low noise figure: 1.8 dB typical, 2.5 dB max
    • Excellent EMI measurement capability
    • Improves system noise floor flatness
    • High linearity and dynamic range
    • Unconditionally stable operation
    • Built-in AC input power with grounding detect circuit
    • Compact, lightweight design (2.8 kg)
    • Optional pulse/ESD protector available

     

  • EMC118A45SE Low Noise Preamplifier | 1–18 GHz, 45 dB Gain

    Key Features:

    • Wide 1–18 GHz frequency range for versatile EMI testing
    • High 45 dB gain with flatness across the band
    • Low noise figure (3.5–8 dB max) for improved sensitivity
    • Compensates long cable loss for accurate EMI measurements
    • Unconditionally stable with high linearity and dynamic range
    • Built-in grounding detect circuit for reliable operation
    • Compact design with 50-ohm SMA female connectors
    • Available in multiple versions with mounting options

     

  • The EMC184040SE is a high-performance low noise preamplifier designed for EMI measurements across 18–40 GHz. With 40 dB gain and a 5 dB noise figure, it ensures reliable, stable, and accurate performance for demanding EMC testing environments.

    Key Features:

    • Wide frequency range: 18–40 GHz
    • 40 dB minimum gain with ±4.5 dB flatness
    • 5 dB noise figure for low-noise operation
    • Compensates for long cable losses in EMI measurements
    • High linearity and dynamic range for precise testing
    • Unconditionally stable design
    • Available in multiple mounting versions (bench, tube clamp, box clamp)

     

  • Key Features:

    • Wide frequency range: 18–40 GHz
    • 40 dB minimum gain with ±4.5 dB flatness
    • 5 dB maximum noise figure for accurate EMI testing
    • Compensates for long cable loss in EMI measurements
    • Enhances system noise floor flatness
    • High linearity LNA for EMI compliance applications
    • High dynamic range and unconditionally stable
    • Built-in AC input power supply with grounding detect circuit
    • Rugged 2.92 mm female connectors for reliability
    • Versions: Bench model and mast-mount with clamp & power supply

     

  • EMCview PC Software Pre-Compliance Testing

    Key Features:

    • Easy-to-use software for radiated and conducted emissions testing.
    • Pre-configured project files for CISPR-xx (EN550xx) standards and automotive EMC standards.
    • Built-in amplitude correction for cables, LISNs, TEM cells, antennas, amplifiers, and probes.
    • Supports spectrum analyzers from Rigol, Siglent, and R&S (FPC/FPH series).
    • Dual measurement runs with Average/Quasi-Peak or Peak/Quasi-Peak modes.
    • Fast Quasi-Peak scan of critical frequencies for efficient troubleshooting.
    • Configurable limit lines, margins, and correction files.
    • Automatic test reports and versatile import/export functions.
    • Ideal for in-house EMC testing, design validation, and cost reduction.

     

  • The EME Wide is a professional wideband field meter designed to monitor and record electromagnetic field (EMF) exposure with accuracy and reliability.

    Key Features:

    • Frequency range: 0.1 MHz – 6.5 GHz
    • Tri-axial probe ensures maximum isotropy in measurements
    • Measures isotropic and single-axis (X, Y, Z) field values
    • Supports RMS, maximum, and time/spatial averaging
    • Selectable units: V/m, A/m, W/m²
    • Built-in alarm with programmable thresholds
    • Large 2.8” LCD display with LED backlight
    • Stores up to 20,000 measurement points in non-volatile memory
    • Rechargeable AA NiMH battery with external wall charger
    • Compliance with 2013/35/EU Directive, ICNIRP, FCC 96-326, and Safety Code 6

     

  • EMScanner: 150 kHz – 8 GHz High-Frequency EMC Desktop Scanner

    Key Features:

    • Wide frequency coverage from 150 kHz to 8 GHz
    • 3.5 mm effective spatial resolution for precise diagnostics
    • Real-time spectral and spatial scans with peak-hold and comparison features
    • Reduces testing time by over 100x and design cycle times by up to 50%
    • Supports emission, immunity, EMI shielding, and broadband noise testing
    • Compact, lightweight, and designed for high-speed, high-density PCB projects
    • EMViewer Software for advanced scan visualization, reporting, and analysis
    • Compatible with leading spectrum analyzers, supporting multiple formats and overlays

     

  • EMScannerR: 150 kHz – 8 GHz, up to 0.06 mm Resolution EMC Desktop Scanner

    Key Features:

    • Frequency coverage from 150 kHz to 8 GHz for complete diagnostics
    • Ultra-high spatial resolution down to 0.06 mm across 8 levels
    • Real-time spectral and spatial scanning with peak-hold and comparison tools
    • Supports JPEG overlays, Gerber RS274x, and HPGL formats
    • Reduces testing time by 100x and design cycle times by up to 50%
    • Identifies hot spots, current loops, and unintended radiators instantly
    • Designed for high-speed, high-density PCB projects across multiple industries
    • EMViewer Software with 3D views, live overlays, and advanced reporting

     

  • EMSCOPE-RX4, 9 kHz – 110 MHz, 4 Channel Receiver for 3 Phase

    Key Features:

    • Quad-channel receiver for complete EMI measurements up to 110 MHz
    • FFT-based dual-channel receiver according to CISPR 16-1-1
    • Peak, Quasi-Peak, and Average detectors
    • Resolution bandwidth filters: 200 Hz, 9 kHz, 120 kHz (CISPR), 1 kHz, 10 kHz (MIL)
    • Fastest receiver in the market with 6 simultaneous measurements
    • Supports common- and differential-mode modal measurements
    • Compact, lightweight design with integrated pre-amp and pulse limiter
    • Software included with real-time results, waterfall function, and auto compliance reports

     

  • The FPP2.3-M Manual Field Probe Positioner is a precise manual height adjustment system for electromagnetic field probes, designed for uniform field calibration in EMC testing environments.

    Key Features:

    • Manual height adjustment: 0.2 – 2.3 m
    • Maximum load capacity: 3 kg
    • Total height: 2.5 m
    • Fabricated from PVC and reinforced fiberglass, fully non-metallic
    • Base dimensions: 0.5 m × 0.5 m with movable wheels
    • Lightweight and portable: approx. 10 kg
    • Compliant with EN61000-4-3 and IEC61000-4-3 standards
    • Ideal for uniform field calibration and precise field probe positioning

     

  • The FPP2.3/1.5 M Field Probe Positioner is a high-precision, remote-controlled axial system designed for fast and automated electromagnetic field measurements.

    Key Features:

    • Remote-controlled horizontal movement for single-axis operation
    • Moves 4 probes to 4 positions for rapid 16-point calibration
    • Automates uniform field calibration (UFA) per EN61000-4-3 / IEC61000-4-3
    • Load capacity: 3 kg
    • Adjustable positioning speed (1–35 cm/s)
    • High accuracy: ±0.5 cm
    • Durable construction: plastic & reinforced fiberglass, minimal metal parts
    • LAN (TCP/IP) interface for full remote operation
    • Compatible with FCU 3.0 or NCD Controller

     

  • A turnkey solution for harmonics and flicker compliance, this system delivers powerful, efficient, and automated testing for today’s high-power demands.

    Key Features:

    • Fully compliant with IEC/EN 61000-3-2, -3-3, -3-11, and -3-12
    • High-power testing up to 75 A and 50 kVA
    • Regenerative AC power supply with energy recovery
    • Programmable simulation: voltage, frequency, harmonics, interharmonics
    • Precision impedance network for accurate flicker measurements
    • Advanced power analyzer with harmonic and flicker metering
    • Preloaded test sequences with automated software control
    • Expandable to include dips, swells, and short interruptions