1 800 665 7301 | info@tmetrix.com

    • Noise reduction of up to 31 dBA, making servers whisper-quiet.
    • Up to 12 kW heat dissipation, ensuring optimal thermal management.
    • IoT-enabled U-Telligent Management System (UMS) for remote monitoring, security, and alerts.
    • Built-in security with internal camera mounting, electronic locking, and real-time access alerts.
    • Available in 12U, 24U, and 42U heights, supporting all major server brands.
    • Flexible installation options, allow for easy integration in offices, labs, and industrial settings.
    • Energy-efficient EC fans, dynamically adjust speed based on heat load to reduce energy costs.
    • Fully enclosed design with soundproof cable entry points, maintaining maximum acoustic performance.

     

  • The CDG 7000 is a new test generator for all standards on immunity to conducted disturbances induced by high-frequency fields – including BCI tests (ISO 11452-4). One of the very few combined IEC 61000-4-6 test systems that contain the RF signal generator, an RF power amplifier, a 3-channel RF voltmeter, and a directional coupler at a very affordable price. IEC 60601-1-2 calling out IEC 61000-4-39 magnetic immunity for close proximity testing requirements can also now be met with the 10 kHz unit.

    • Frequency Range:
      • 10 kHz – 30 MHz Conducted
      • 5 MHz – 1GHz Radiated
    • Frequency step:
      • 10/500 kHz switchable CE
      • 5/10 MHz switchable RE
    • Includes: Generator, antenna, charger, wood case

     

    • 10 kHz – 3 GHz, 40dB Gain, 5dB N.F.
    • Compensation for long cable loss for EMI Measurement
    • Improve system noise floor flatness
    • High EMI performance
    • High linearity LNA for EMI measurement
    • High dynamic range
    • Unconditionally Stable
    • State-of-the-Art Technology

     

    • EMI Measurements:
      • FFT-based dual-channel receiver
      • According to CISPR16-1-1
      • Peak, Quasi-Peak, and Average Detectors
      • Resolution Bandwidth Filters of 200 Hz, 9 kHz, and 120 kHz (CISPR), and 1 kHz and 10 kHz (MIL)
      • The fastest receiver in the market: Line and Neutral measurements with the 3 detectors simultaneously (6 simultaneous measurements)

     

  • Unleash the power of modern, versatile, and sophisticated AC sources with our LSX Series – Programmable AC Power Source. These powerhouses come in single and three-phase options, ranging from 1.5kVA to 6kVA. Equipped with an advanced programmable controller featuring a vivid colour touchscreen interface, the LSX Series is not just cost-effective but also fully programmable for basic frequency conversion, advanced AC power line disturbance tests, and ATE applications.

     

  • Key Features Provide Application Versatility

    • USB, LAN (LXI), IEEE-488.2 and RS-232C with SCPI compatibility
    • Compatible with PPSC Studio graphical user interface
    • LabVIEW for Windows®/LabWindows® drivers
    • Waveform Creation by Harmonic Synthesis
    • Waveform Capture (Voltage and Current)
    • Harmonic Analysis (Voltage and Current)
    • Metering of RMS and Peak Values
    • Continuous Self Calibration (CSC)
    • Line Sync
    • 6:1 Peak Current Capability
    • Low Impedance for EN61000-3-2, 3 Testing
    • Programmable Output Impedance
    • Up to 0-300 VAC Direct Coupled Out
    • 1 Phase / 3 Phase Switch Selectable
    • 15-5000 Hz Full Power Bandwidth
    • Power Levels from 500 VA to 6 kVA standard; 30kVA optional
    • Externally Referenced Meter Calibration
    • CE Safety & EMC and NTRL Safety Mark

     

  • The AZX Series (Regenerative AC / DC Power Source) is a family of high power, single, split and three phase, AC, DC and AC+DC output capable Power Sources with full energy recovery to the AC mains when sinking power from the equipment under test. Available models range from 30 kVA to 440 kVA. Using a modern color touch screen based user interface for ease of use, the AZX Series is cost effective and fully programmable for both basic frequency conversion and advanced AC power line or DC power disturbance test applications requiring up to 1000 Hz fundamental frequency.

    The energy recovery capability allows both sourcing and sinking of current and power up to 100% of rated power. Adding the Load Option (Option L) adds full electronic regenerative AC & DC Load programming capability to the AZX.

     

  • Karis SRK Series Server Cabinets are a reliable way to keep sensitive electronics safe. The professional design features a ventilation rate of more than 74%, providing adequate cooling for the entire system. Karis’s server cabinets will make integrating your data center or data closet fast and easy.

    • Curved locking front door with ventilation rate above 80%
    • Split locking rear door with ventilation rate above 80%
    • Horizontally split locking side panels make access easy
    • Two heights, two depths, and two widths available
    • Rear vertical cable managers (two) include
    • Square hole mounting rails are adjustable front to rear
    • Grounding kit included
    • Levelers and heavy duty casters come standard
    • Full range of optional accessories
    • 5 year warranty

     

  • HDO4000A oscilloscopes have 4 analog input channels, 12-bit resolution using Teledyne LeCroy’s HD4096 high-definition technology, up to 1 GHz of bandwidth and a compact form factor with a large 12.1” multi-touch display. They are ideal for debug and troubleshooting of power electronics designs, digital power management or power integrity analysis, automotive electronics systems, and deeply embedded or mechatronic designs.

     

  • The WaveSurfer 3000z has a 10.1″ capacitive touch display, the longest memory, and the deepest toolbox – all at an affordable price.

    • HD4096 technology provides 12-bit resolution all the time
    • 2ProBus input supports over 30 probes in 9 product categories
    • 3Long record capture of up to 25 Mpts
    • 412.1” 1280 x 800 HD capacitive touchscreen
    • 5Mixed-signal capability – debug complex embedded designs with integrated 16-channel mixed signal option
    • 6Easy connectivity with 2 USB 3.1 ports
    • 7MAUI with OneTouch user interface for intuitive and efficient operation

     

    • 15.6″ 1920 x 1080 capacitive touchscreen display
    • 24 analog input channels
    • 3ProBus input supports every Teledyne LeCroy probe
    • 4MAUI with OneTouch user interface for intuitive and efficient operation
    • 5Q-Scape multi-tab display architecture
    • 6Up to 250 Mpts of acquisition memory
    • 7HD4096 technology – 12 bits all the time
    • 8Buttons/indicators color-coded to associated waveform on display
    • 9Use cursors and adjust settings without opening a menu
    • 10Mixed Signal capability with 16 integrated digital channels
    • 116 USB 3.1 ports (2 front, 4 side)

     

    • HD4096 technology provides 12-bit resolution up to 8 GHz and 20 GS/s
    • Up to 5 Gpts of acquisition memory enables detailed viewing of long events
    • 15.6” 1900 x 1080 Full HD capacitive touchscreen
    • ProBus2 input supports up to 8 GHz bandwidth while maintaining support for legacy ProBus probes
    • MAUI with OneTouch user interface for intuitive and efficient operation
    • Waveform Control Knobs – Control channel, zoom, math and memory traces with the multiplexed vertical and horizontal knobs
    • Color-coded panel indicators – Trigger, horizontal and vertical indicator colors correspond to the associated waveform on the display
    • Cursor/Adjust Knobs – Enable and position cursors or adjust settings and parameters without opening a menu
    • Mixed Signal Capability – Debug complex embedded designs with integrated 16-channel mixed signal capability
    • Easy connectivity with seven USB 3.1 ports (3 front, 4 side) and UHD (4k) HDMI and DisplayPort outputs

     

    • Eye diagram (a), eye mask failure (b) and IsoBER eye opening analysis (c)
    • Jitter spectrum (a) with noise floor display (b) and inverse FFT of the periodic jitter (c)
    • Data dependent jitter (DDj) plot for each bit in synch with pattern (a) and with histogram (b)
    • Time interval error (TIE) jitter track analysis
    • Jitter histograms (a) with bathtub curves (b) and CDF plot (c)
    • Intersymbol interference (ISI) plots pinpoint bit sequences that have high ISI and are sources of bit errors
    • Jitter measurements table with full details for one or more “lanes” plus reference

     

    • 15.6” 1920 x 1080 capacitive touchscreen display
    • 8 analog input channels
    • ProBus input supports every Teledyne LeCroy probe
    • MAUI with OneTouch user interface for intuitive and efficient operation
    • Q-Scape multi-tab display architecture
    • Up to 5 Gpts of acquisition memory
    • HD4096 technology – 12 bits all the time
    • Buttons/indicators color-coded to associated waveform on display
    • Use cursors and adjust settings without opening a menu
    • Mixed Signal capability with 16 integrated digital channels
    • 6 USB 3.1 ports (2 front, 4 side)
    • HDMI and DisplayPort – supports 4K (4096 x 2304) external monitor
    • Removable SSD (standard)
    • View 16 channels on one display with OscilloSYNC
    • Reference Clock Input/Output for connecting to other equipment
    • USBTMC over USB 3.1 for fast data offload