1 800 665 7301 | info@tmetrix.com

  • The EME Guard XS Radar is a state-of-the-art RF safety monitor, specifically designed for workers operating near radar transmitters and antennas. With its isotropic tri-axis E-field sensors, this compact device provides continuous EMF monitoring over a frequency range of 1 MHz to 40 GHz, including short pulsed signal detection. Equipped with audio and visual alarms, it alerts users instantly when EMF exposure exceeds predefined safety thresholds, creating a safer working environment for military, aviation, and telecom personnel.

     

  • Solutions For:

    •  Accurate measurement with tri-axis sensors
    • Instant audio and visual alarm
    • Robust, reliable and user-friendly
    • Covers 5G / 6G bands, measuring up to 71 GHz

    User profile:

    • Persons working near antennas including installation and maintenance workers, broadcast, PMR and mobile phone operators or regulatory body employees

    Measurement capabilities:

    • Continuous monitoring of Electromagnetic Field levels with isotropic tri-axis E-field sensors
    • EMF Level indicated by a LED color scale
    • Audio and visual alarms triggered when EMF exceeds the reference level
    • EMI Measurements:
      • FFT-based dual-channel receiver
      • According to CISPR16-1-1
      • Peak, Quasi-Peak, and Average Detectors
      • Resolution Bandwidth Filters of 200 Hz, 9 kHz, and 120 kHz (CISPR), and 1 kHz and 10 kHz (MIL)
      • The fastest receiver in the market: Line and Neutral measurements with the 3 detectors simultaneously (6 simultaneous measurements)

     

  • Unleash the power of modern, versatile, and sophisticated AC sources with our LSX Series – Programmable AC Power Source. These powerhouses come in single and three-phase options, ranging from 1.5kVA to 6kVA. Equipped with an advanced programmable controller featuring a vivid colour touchscreen interface, the LSX Series is not just cost-effective but also fully programmable for basic frequency conversion, advanced AC power line disturbance tests, and ATE applications.

     

  • Key Features Provide Application Versatility

    • USB, LAN (LXI), IEEE-488.2 and RS-232C with SCPI compatibility
    • Compatible with PPSC Studio graphical user interface
    • LabVIEW for Windows®/LabWindows® drivers
    • Waveform Creation by Harmonic Synthesis
    • Waveform Capture (Voltage and Current)
    • Harmonic Analysis (Voltage and Current)
    • Metering of RMS and Peak Values
    • Continuous Self Calibration (CSC)
    • Line Sync
    • 6:1 Peak Current Capability
    • Low Impedance for EN61000-3-2, 3 Testing
    • Programmable Output Impedance
    • Up to 0-300 VAC Direct Coupled Out
    • 1 Phase / 3 Phase Switch Selectable
    • 15-5000 Hz Full Power Bandwidth
    • Power Levels from 500 VA to 6 kVA standard; 30kVA optional
    • Externally Referenced Meter Calibration
    • CE Safety & EMC and NTRL Safety Mark

     

  • The AZX Series (Regenerative AC / DC Power Source) is a family of high power, single, split and three phase, AC, DC and AC+DC output capable Power Sources with full energy recovery to the AC mains when sinking power from the equipment under test. Available models range from 30 kVA to 440 kVA. Using a modern color touch screen based user interface for ease of use, the AZX Series is cost effective and fully programmable for both basic frequency conversion and advanced AC power line or DC power disturbance test applications requiring up to 1000 Hz fundamental frequency.

    The energy recovery capability allows both sourcing and sinking of current and power up to 100% of rated power. Adding the Load Option (Option L) adds full electronic regenerative AC & DC Load programming capability to the AZX.

     

    • Protocol reports
    • Generation of waveforms with synchronous data acquisition
    • Modular Expandable
    • Individual Waveform Generation
    • Standard Libraries included
    • Unlimited Waveform size
    • 2 different Waveforms synchronously
    • DLL’s for LabView, Vector CANoe / CAPL, C#, C++, ANSI C, Python, etc.
    • Simulation of imported oscilloscope waveform

     

  • BOLAB revolutionizes EV testing with powerful, flexible, and modular HV Electric Vehicle Test Systems. These solutions offer high-speed testing, covering diverse profiles and budgets. Features include a modular design, adaptability, and WaveMaster Software for custom waveforms. Benefit from efficiency, precision, and cost-efficiency in EV testing. Discover the future of high-speed testing with BOLAB’s innovative solutions.

  • Phase -Models Kitted for installation into End User’s Cabinet  and Phase -Models including Cabinet and Emergency Power off  (EPO)1

     

  • AC, DC, AC+DC, Single and Three – Phase -Models Including Cabinets

    Rated Power 60,000 (vA),  Output Power 21,000(w)  Output form  1,2,3Ø, Output Volt-Max 300(L-N)/425 (VAC/VDC)(1), Output AMPS/PHS 166.7 / 83.3 (AAC/ADC)(2), Input Power Form (3) 3 Ø, Panel Height (4) 27 (U) and Weight 527/240 (LBS./KG).

     

  • AC, DC, AC+DC, Single and Three – Phase -Models Including Cabinets

    Rated Power 60,000 (vA),  Output Power 21,000(w)  Output form  1,2,3Ø, Output Volt-Max 300(L-N)/425 (VAC/VDC)(1), Output AMPS/PHS 166.7 / 83.3 (AAC/ADC)(2), Input Power Form (3) 3 Ø, Panel Height (4) 27 (U) and Weight 527/240 (LBS./KG).

     

  • AC, DC, AC+DC, Single and Three – Phase -Models Including Cabinets

    Rated Power 30,000 (vA),  Output Power 21,000(w)  Output form  1,2,3Ø, Output Volt-Max 300(L-N)/425 (VAC/VDC)(1), Output AMPS/PHS 125.0 / 62.5  (AAC/ADC)(2), Input Power Form (3) 3 Ø, Panel Height (4) 27 (U) and Weight 466/212 (LBS./KG).

     

  • AC, DC, AC+DC, Single and Three – Phase -Models Including Cabinets

    Rated Power 30,000 (vA),  Output Power 21,000(w)  Output form  1,2,3Ø, Output Volt-Max 300(L-N)/425 (VAC/VDC)(1), Output AMPS/PHS 125.0 / 62.5  (AAC/ADC)(2), Input Power Form (3) 3 Ø, Panel Height (4) 27 (U) and Weight 466/212 (LBS./KG).

     

  • AC, DC, AC+DC, Single and Three – Phase -Models Including Cabinets

    Rated Power 30,000 (vA),  Output Power 21,000(w)  Output form  1,2,3Ø, Output Volt-Max 300(L-N)/425 (VAC/VDC)(1), Output AMPS/PHS 25.0/13.9 (AAC/ADC)(2), Input Power Form (3) 3 Ø, Panel Height (4) 15 (U) and Weight 320/146(LBS./KG).

     

  • AC, DC, AC+DC, Single and Three – Phase -Models Including Cabinets

    Rated Power 30,000 (vA),  Output Power 21,000(w)  Output form  1,2,3Ø, Output Volt-Max 300(L-N)/425 (VAC/VDC)(1), Output AMPS/PHS 25.0/13.9 (AAC/ADC)(2), Input Power Form (3) 3 Ø, Panel Height (4) 15 (U) and Weight 320/146(LBS./KG).

     

  • AC, DC, AC+DC, Single and Three – Phase -Models without Cabinets

    Rated Power 15000 (vA),  Outputform  1,2,3Ø, Output Volt-Max 300(L-N)/425 (VAC/VDC)(1), Output AMPS/PHS 41.7 / 21.0 (AAC/ADC)(2), Input Power Form (3) 3 Ø, Panel Height (4) 4 (U) and Weight 112/51 (LBS./KG).