1 800 665 7301 | info@tmetrix.com

  • The CDG 7000 is a new test generator for all standards on immunity to conducted disturbances induced by high-frequency fields – including BCI tests (ISO 11452-4). One of the very few combined IEC 61000-4-6 test systems that contain the RF signal generator, an RF power amplifier, a 3-channel RF voltmeter, and a directional coupler at a very affordable price. IEC 60601-1-2 calling out IEC 61000-4-39 magnetic immunity for close proximity testing requirements can also now be met with the 10 kHz unit.

    • Frequency Range:
      • 10 kHz – 30 MHz Conducted
      • 5 MHz – 1GHz Radiated
    • Frequency step:
      • 10/500 kHz switchable CE
      • 5/10 MHz switchable RE
    • Includes: Generator, antenna, charger, wood case

     

    • 10 kHz – 3 GHz, 40dB Gain, 5dB N.F.
    • Compensation for long cable loss for EMI Measurement
    • Improve system noise floor flatness
    • High EMI performance
    • High linearity LNA for EMI measurement
    • High dynamic range
    • Unconditionally Stable
    • State-of-the-Art Technology

     

  • The EME Guard Plus is a lightweight and robust personal protection monitor designed to ensure the safety of workers operating near electromagnetic field (EMF) emitters such as antennas, radars, and base stations. With a frequency range of 1 MHz to 40 GHz, this device continuously monitors and records EMF exposure levels while providing immediate audio, visual, and vibrating alerts when exposure exceeds predefined safety thresholds. Customizable alarm settings and a triaxial isotropic probe ensure accurate and reliable measurements.

     

  • The EME Guard XS Radar is a state-of-the-art RF safety monitor, specifically designed for workers operating near radar transmitters and antennas. With its isotropic tri-axis E-field sensors, this compact device provides continuous EMF monitoring over a frequency range of 1 MHz to 40 GHz, including short pulsed signal detection. Equipped with audio and visual alarms, it alerts users instantly when EMF exposure exceeds predefined safety thresholds, creating a safer working environment for military, aviation, and telecom personnel.

     

  • Solutions For:

    •  Accurate measurement with tri-axis sensors
    • Instant audio and visual alarm
    • Robust, reliable and user-friendly
    • Covers 5G / 6G bands, measuring up to 71 GHz

    User profile:

    • Persons working near antennas including installation and maintenance workers, broadcast, PMR and mobile phone operators or regulatory body employees

    Measurement capabilities:

    • Continuous monitoring of Electromagnetic Field levels with isotropic tri-axis E-field sensors
    • EMF Level indicated by a LED color scale
    • Audio and visual alarms triggered when EMF exceeds the reference level
    • EMI Measurements:
      • FFT-based dual-channel receiver
      • According to CISPR16-1-1
      • Peak, Quasi-Peak, and Average Detectors
      • Resolution Bandwidth Filters of 200 Hz, 9 kHz, and 120 kHz (CISPR), and 1 kHz and 10 kHz (MIL)
      • The fastest receiver in the market: Line and Neutral measurements with the 3 detectors simultaneously (6 simultaneous measurements)

     

  • HDO4000A oscilloscopes have 4 analog input channels, 12-bit resolution using Teledyne LeCroy’s HD4096 high-definition technology, up to 1 GHz of bandwidth and a compact form factor with a large 12.1” multi-touch display. They are ideal for debug and troubleshooting of power electronics designs, digital power management or power integrity analysis, automotive electronics systems, and deeply embedded or mechatronic designs.

     

  • The WaveSurfer 3000z has a 10.1″ capacitive touch display, the longest memory, and the deepest toolbox – all at an affordable price.

    • HD4096 technology provides 12-bit resolution all the time
    • 2ProBus input supports over 30 probes in 9 product categories
    • 3Long record capture of up to 25 Mpts
    • 412.1” 1280 x 800 HD capacitive touchscreen
    • 5Mixed-signal capability – debug complex embedded designs with integrated 16-channel mixed signal option
    • 6Easy connectivity with 2 USB 3.1 ports
    • 7MAUI with OneTouch user interface for intuitive and efficient operation

     

    • 15.6″ 1920 x 1080 capacitive touchscreen display
    • 24 analog input channels
    • 3ProBus input supports every Teledyne LeCroy probe
    • 4MAUI with OneTouch user interface for intuitive and efficient operation
    • 5Q-Scape multi-tab display architecture
    • 6Up to 250 Mpts of acquisition memory
    • 7HD4096 technology – 12 bits all the time
    • 8Buttons/indicators color-coded to associated waveform on display
    • 9Use cursors and adjust settings without opening a menu
    • 10Mixed Signal capability with 16 integrated digital channels
    • 116 USB 3.1 ports (2 front, 4 side)

     

    • HD4096 technology provides 12-bit resolution up to 8 GHz and 20 GS/s
    • Up to 5 Gpts of acquisition memory enables detailed viewing of long events
    • 15.6” 1900 x 1080 Full HD capacitive touchscreen
    • ProBus2 input supports up to 8 GHz bandwidth while maintaining support for legacy ProBus probes
    • MAUI with OneTouch user interface for intuitive and efficient operation
    • Waveform Control Knobs – Control channel, zoom, math and memory traces with the multiplexed vertical and horizontal knobs
    • Color-coded panel indicators – Trigger, horizontal and vertical indicator colors correspond to the associated waveform on the display
    • Cursor/Adjust Knobs – Enable and position cursors or adjust settings and parameters without opening a menu
    • Mixed Signal Capability – Debug complex embedded designs with integrated 16-channel mixed signal capability
    • Easy connectivity with seven USB 3.1 ports (3 front, 4 side) and UHD (4k) HDMI and DisplayPort outputs

     

    • Eye diagram (a), eye mask failure (b) and IsoBER eye opening analysis (c)
    • Jitter spectrum (a) with noise floor display (b) and inverse FFT of the periodic jitter (c)
    • Data dependent jitter (DDj) plot for each bit in synch with pattern (a) and with histogram (b)
    • Time interval error (TIE) jitter track analysis
    • Jitter histograms (a) with bathtub curves (b) and CDF plot (c)
    • Intersymbol interference (ISI) plots pinpoint bit sequences that have high ISI and are sources of bit errors
    • Jitter measurements table with full details for one or more “lanes” plus reference

     

    • 15.6” 1920 x 1080 capacitive touchscreen display
    • 8 analog input channels
    • ProBus input supports every Teledyne LeCroy probe
    • MAUI with OneTouch user interface for intuitive and efficient operation
    • Q-Scape multi-tab display architecture
    • Up to 5 Gpts of acquisition memory
    • HD4096 technology – 12 bits all the time
    • Buttons/indicators color-coded to associated waveform on display
    • Use cursors and adjust settings without opening a menu
    • Mixed Signal capability with 16 integrated digital channels
    • 6 USB 3.1 ports (2 front, 4 side)
    • HDMI and DisplayPort – supports 4K (4096 x 2304) external monitor
    • Removable SSD (standard)
    • View 16 channels on one display with OscilloSYNC
    • Reference Clock Input/Output for connecting to other equipment
    • USBTMC over USB 3.1 for fast data offload

     

    • S-parameters DC to 40 GHz, single-ended and mixed-mode
    • Impedance Profile with <1 mm resolution, differential and common-mode
    • Internal, automatic OSLT calibration
    • USB-connected, small, lightweight
    • Flexible display of the measurements
    • Remove effects from fixtures, connectors and cables
    • Emulate eye diagrams with CTLE, DFE and FFE equalization
    • Advanced jitter analysis

     

    • 4/8 analog channels + 1 external trigger
    • Analog channel bandwidth: up to 2 Ghz; real-time sampling rate of up to 10 GSa/s
    • Vertical resolution: 12-bits
    • Low noise floor: 153 μVrms at full bandwidth of 2 GHz
    • New generation of high speed display technology:
      • Waveform capture rates up to 170,000 wfm/s (normal mode), and 750,000 wfm/s (sequence mode)
      • Supports 256-level intensity grading and color temperature display modes
      • Memory depth up to 500 Mpts/channel
      • Digital trigger system
    • Intelligent trigger: Edge, Slope, Pulse, Window, Runt, Interval, Dropout, Pattern, Qualified, Nth edge, Setup/hold, Delay and Video (HDTV supported)
    • Serial bus triggering and decoder, supports protocols I2C, SPI, UART, CAN, LIN, CAN FD, FlexRay, I2S, MIL-STD-1553B, SENT and Manchester as standard
    • Segmented acquisition (Sequence) mode, dividing the maximum record length into multiple segments (up to 80,000), according to trigger conditions set by the user, with a very small dead time between segments to capture the qualifying event
    • History waveform record (History) function, the maximum recorded waveform length is 80,000 frames
    • Automatic measurements on 50+ parameters, supports statistics with histogram, track, trend, Gating measurement, and measurements on Math, History, Memory and Ref
    • 4 Math traces (8 Mpts FFT, addition, subtraction, multiplication, division, integration, differential, square root, etc.), supports formula editor