Showing 49–64 of 72 results


  • The RADIO EMC software by NEXIO is a powerful automation platform designed for RF and electromagnetic compliance testing. It enables fully automated radio frequency measurements, spurious emission analysis, and standardized testing workflows for modern wireless communication systems.

    Key Features

    • Automated RF and radio compliance testing workflow
    • Supports ETSI standards including 300 328, 300 220, and 301 908 series
    • Spurious and unwanted emission detection with automatic remeasurement
    • Integrated chamber calibration for accurate EIRP and ERP calculations
    • Supports GSM, LTE, 5G, WiFi, Bluetooth, and SRD technologies
    • Automated antenna mast and turntable control for full scan coverage
    • Configurable bandwidth and sub-band sequencing optimization
    • Substitution method for precise radiated power measurement
    • Real time detection of limit-exceeding emissions
    • Automatic generation of detailed RF compliance test reports

     

  • Any shielded room can be transformed into a reverberation chamber with this retrofit solution. Designed with aluminum panels and customizable stirrers, it ensures improved Q factor and precise EMC testing conditions.

    Key Features:

    • Converts shielded rooms into functional reverberation chambers
    • High Q factor for enhanced electromagnetic testing
    • Customizable stirrer configurations (1 or 2+ stirrers)
    • Ensures strong electrical bonding to prevent oxidation
    • Suitable for automotive, avionics, military, space, and telecom markets
    • Compatible with IEC/EN 61000-4-20 & IEC/EN 61000-4-3 standards

     

  • SB3G Shielded Box – EMI & RF Protection provides advanced shielding for sensitive equipment in high-interference environments.

    Key Features:

    • Superior EMI/RF shielding up to 60 dB attenuation
    • Wideband performance: DC – 3 GHz
    • Integrated AC power filter (120/230V, 10A fuse)
    • Multiple I/O ports: RF, fiber optic, USB, Ethernet
    • Active cooling with thermostat-controlled fan
    • Shielded viewing window for real-time monitoring
    • Durable, lightweight aluminum enclosure (19 kg)

     

  • Shielded Chamber and Box Solutions are engineered for high-performance RF, EMI, and EMC testing across industries. Designed for 5G, aerospace, automotive, and military use, these solutions deliver exceptional shielding effectiveness with customizable options.

    Key Features:

    • Wide range of shielded chambers and boxes for commercial, industrial, and defense applications
    • Effective for RF immunity testing, antenna measurements, and shielding verification
    • Supports 5G and wireless/telecom testing environments
    • Compatible with IEC/EN 61000-4-20 and IEC/EN 61000-4-3 standards
    • Available in multiple models: SHB-50, SHB-50A, SHB-100, SHB-200, and Aluminum Shelter
    • Custom-built solutions to meet specific testing needs
    • Supports shielding effectiveness test setup with advanced antenna configurations

     

  • Key Features:

    • Free-standing turntable designed for electromagnetic absorption chambers
    • 0.3 m diameter with 50 kg load capacity
    • Height: 190 mm, made of rigid PVC skin-foam sheets
    • Rotating speed adjustable from 0.1 rpm to 2.5 rpm
    • High positioning accuracy of ±0.5°
    • Rotation angle: -200° to 400° with synchronous servo motor
    • LAN (TCP/IP) control option via FCU3.0 or NCD Controller
    • Central 50 mm opening for power supply insertion
    • Interference suppression: 20 dB under DIN EN 55011:2018-05 class B
    • Ideal for automotive, telecom, medical, and industrial EMC testing

     

  • The TT 1.0 PF Turn Table is a precision turntable designed for EMC and RF testing in anechoic and electromagnetic absorption chambers.

    Key Features:

    • Diameter: 1.0 m; height: 190 mm
    • Load capacity up to 100 kg
    • Free-standing design for chamber floor installation
    • Adjustable rotation speed: 0.1–2.5 rpm
    • Positioning accuracy: ±0.5°
    • Rotating angle range: -200° to 400°
    • Central 50 mm opening for power supply connections
    • Controlled via LAN (TCP/IP) with FCU3.0 or NCD Controllers
    • Durable PVC integral skin-foam cover plate
    • Synchronous servo motor with toothed belt and worm gear drive

     

  • VRC Reverb Tent Chamber is a flexible, modular electromagnetic test facility designed for immunity and emission testing with high efficiency and portability.

    Key Features:

    • Flexible metallic fabric tent construction
    • Wide frequency range (up to 18 GHz)
    • Mechanical vibration walls (5–20 Hz) for uniform reverberation
    • Faster test throughput compared to traditional methods
    • Modular, customizable dimensions for large or small DUTs
    • Compliant with IEC 61000-4-21 and MIL-STD-461 standards
    • Easy to assemble, disassemble, and transport
    • Optional accessories: antennas, filters, control rooms

     

    • Versatile Current Sensing: Accurately measure small and large currents, from sub-milliamp levels to thousands of amps.
    • High-Speed Pulse Monitoring: Patented distributed termination technology enables ultra-fast rise time measurement (as short as 2ns).
    • Enhanced Noise Immunity & Safety: Double shielding minimizes external noise, making these monitors ideal for high-voltage applications.
    • Robust Construction: Sealed models are suitable for high-voltage insulating oil or vacuum environments.
    • Broad Compatibility: Works with oscilloscopes, spectrum analyzers, power analyzers, digital voltmeters, ADCs, and more.

     

    Select options This product has multiple variants. The options may be chosen on the product page
    Learn More
  • High-Precision Current Measurement with BNC Connectivity

    • Precision Current Sensing: ±1% accuracy ensures reliable real-time current monitoring.
    • BNC Connector for Seamless Connectivity: Works with oscilloscopes, ADCs, spectrum analyzers, and power analyzers.
    • Clamp-On Design for Non-Intrusive Measurement: Safely monitor live current flow without circuit disruption.
    • 50 Ohm Termination Compatible: Output reduces by half when using a 50Ω termination.
    • High-Voltage Safety Considerations: Conductive case requires adequate insulation for user safety.

     

    Select options This product has multiple variants. The options may be chosen on the product page
    Learn More
  • High-Precision Current Sensing with BNC Connectivity

    • High-Precision Measurement: ±1% accuracy for reliable current sensing.
    • Customizable Configurations: Designed to meet specific user requirements for precision measurement.
    • BNC Connector for Easy Integration: Works with oscilloscopes, ADCs, spectrum analyzers, and power analyzers.
    • Non-Insulated Conductive Case: Proper insulation must be provided on the monitored conductor.
    • 50 Ohm Termination Compatibility: Using a 50Ω termination reduces the output to half.

     

  • High-Precision Voltage Measurement Up to 500kV

    • High-Voltage Measurement Capability: Supports up to 500kV in insulating oil and customizable calibration for air use.
    • Precision Division Ratios: Models with 5000:1, 10,000:1, and custom ratios, ensuring reliable voltage scaling.
    • Temperature-Compensated Accuracy: ±1% over 20°C to 80°C, providing stable voltage readings.
    • Robust Design for Harsh Environments: Sealed for high-voltage insulating oil use, with custom air calibration available.
    • Safe Operation with Ground Loop Control: The outer conductor is isolated from the case, allowing controlled grounding connections.

     

  • Precision Pulse Output Up to 500kV

    • Wide Voltage Range: Supports 100kV to 500kV pulse outputs for high-energy applications.
    • Fast Pulse Transmission: Pulse durations from 0.25 to 50 microseconds, ensuring efficient energy transfer.
    • Insulating Oil Immersion: Open-construction design for operation in high-voltage insulating oil, reducing breakdown risks.
    • Advanced Overvoltage Protection: Designed with built-in safety factors (50-100%) to prevent damage from overvoltages.
    • Reliable Flashover Protection: Corona ring-to-core insulation prevents damage from accidental flashovers.

     

  • The CDG 7000 is a new test generator for all standards on immunity to conducted disturbances induced by high-frequency fields – including BCI tests (ISO 11452-4). One of the very few combined IEC 61000-4-6 test systems that contain the RF signal generator, an RF power amplifier, a 3-channel RF voltmeter, and a directional coupler at a very affordable price. IEC 60601-1-2 calling out IEC 61000-4-39 magnetic immunity for close proximity testing requirements can also now be met with the 10 kHz unit.

    • Frequency Range:
      • 10 kHz – 30 MHz Conducted
      • 5 MHz – 1GHz Radiated
    • Frequency step:
      • 10/500 kHz switchable CE
      • 5/10 MHz switchable RE
    • Includes: Generator, antenna, charger, wood case

     

    • 10 kHz – 3 GHz, 40dB Gain, 5dB N.F.
    • Compensation for long cable loss for EMI Measurement
    • Improve system noise floor flatness
    • High EMI performance
    • High linearity LNA for EMI measurement
    • High dynamic range
    • Unconditionally Stable
    • State-of-the-Art Technology

     

    • EMI Measurements:
      • FFT-based dual-channel receiver
      • According to CISPR16-1-1
      • Peak, Quasi-Peak, and Average Detectors
      • Resolution Bandwidth Filters of 200 Hz, 9 kHz, and 120 kHz (CISPR), and 1 kHz and 10 kHz (MIL)
      • The fastest receiver in the market: Line and Neutral measurements with the 3 detectors simultaneously (6 simultaneous measurements)

     