1 800 665 7301 | info@tmetrix.com

    • 150kHz to 3GHz (TGR2053) and 150kHz to 1.5GHz (TGR2051) frequency range
    • High signal purity, phase noise <-117dBc/Hz (typical) at 1GHz output and 10kHz offset
    • Amplitude range of -127dBm to +13dBm
    • 0.1dBm amplitude setting resolution
    • Internal or external analogue modulations (AM, FM, PM)
    • Amplitude can be set in dBm, dBμV or in linear Volts.
    • Internal or external digital modulations – ASK, OOK, FSK, 3FSK, 4FSK, GFSK, MSK, GMSK, HMSK & PSK with U01 option
    • Modulation Synchronisation
    • Fast amplitude and/or frequency sweeps with comprehensive triggering
    • 5ms sweep settling time
    • 1ppm frequency accuracy, <1ppm drift in first year
    • Modulation waveform output on the rear panel
    • Internal waveforms include: Sine, Square, Ramp, Triangle, PRBS (various lengths) and user-defined pattern
    • Simple operation with the colour touch screen
    • Programmable via USB, LAN (LXI) and GPIB (optional), SCPI compatible
    • Compatible with previous Aim-TTi RF generators

     

  • Karis SRK Series Server Cabinets are a reliable way to keep sensitive electronics safe. The professional design features a ventilation rate of more than 74%, providing adequate cooling for the entire system. Karis’s server cabinets will make integrating your data center or data closet fast and easy.

    • Curved locking front door with ventilation rate above 80%
    • Split locking rear door with ventilation rate above 80%
    • Horizontally split locking side panels make access easy
    • Two heights, two depths, and two widths available
    • Rear vertical cable managers (two) include
    • Square hole mounting rails are adjustable front to rear
    • Grounding kit included
    • Levelers and heavy duty casters come standard
    • Full range of optional accessories
    • 5 year warranty

     

    • Customizable & savable test setups
    • Program & Datalog Storage
    • User Defined Temperature Limits
    • Local & Remote Operations
    • LabView™ drivers
    • IEEE-488, RS232 ports

     

     

    • 20 Amp Operation: Full performance with 20 amp service
    • Automatic Power Reduction: Reduces power usage during idle periods
    • Heat Only Mode: Reduces power usage when cold temperatures are not used
    • WhisperStream Technology: quieter, smooth-sounding operation, 56 dBA
    • Frost Free Test Environment: dry air purge for tester interface, prevents condensation:
      0.5 to 3scfm (0.25 to 1.5 l/s)
    • Heated Defrost: quickly removes moisture buildup from internal chiller
    • DUT Temperature Control : Proprietary control algorithm enables DUT temperature to be directly controlled
    • Transition Rate*
      -55 to +125°C, approx. 10 seconds
      125 to -55°C, approx. 10 seconds
    • System Airflow Output*
      4 to 18scfm (1.9 to 8.5 l/s) Continuous
    • Temperature Range*
      -80 to +225°C (60Hz) No LN2 or LCO2 Required

     

    • High reliability thermal cycling without thermoelectric modules
    • Temperature range: -65 to 175°C
    • Cooling power:
      • 40W at -40°C for lower power devices
      • 55W at -55°C and 120W at -40°C.
    • Transition rate: up to <35 sec over 25 to -40°C
    • Easy and secure thermal connection to in-circuit or test socked DUT
    • Touch-screen controller: user-programmable temperatures, graphing, data logging
    • Communications options: Ethernet, USB, IEEE, RS232

     

  • -60° to +200°C

    • Economy model with high thermal capacity
    • Precise temperatures with fast transitions from -60 to 200°C
    • No annual leak testing required per EU 517/2014 F-Gas Regulation
    • Effective testing and conditioning of electronic components, boards, and modules
    • Available for 50 and 60Hz operation
    • No need for Liquid Nitrogen (LN2) or Liquid Carbon Dioxide (LCO2)
    • Remote communications and set up and touch screen operation
    • User Defined Temperature Limits

     

     

  • Key Performance Capabilities:

    • Slew rates up to 60 V/µsec.
    • Up to 240A DC at +50VDC or –50VDC (4301-240 configuration).
    • Can provide pulses of up to 800 amps at voltages of up to ±100V (4301-240 configuration).
    • Adjustable compensation allows the system to maintain a 50V/2 µsec rise-time over a wide range of current outputs.

     

  • Key Performance Capabilities:

    • Bandwidth: DC to 50 kHz
    • Voltage: 0 to 250 VRMS; 0 to 350 VDC
    • Current: 100 to 500 ARMS
    • Distortion: 0.1%
    • Power: 4 kW to 20 kW*Power levels up to 5X rated power when driving reactive loads
    • High power efficiency and density

    *Models available with output from 4 kW to 20 kW (capable of up to 125 kVA).

     

  • Key Performance Capabilities:

    • 4-Quadrant – Can source and sink current
    • ±80V – DC supply for 12V to 48V systems; meets 80V surge requirements
    • 300 kHz Sine – DC ripple tests for all major standards
    • 3µs Rise Time – Exceeds surge and dropout slew rate requirements
    • 3mΩ DC Source Impedance – Out-performs ISO 7637-2 requirements
    • Supports ground reference and supply offset testing required for ISO 16750-2 Sect. 4.8 and other similar standards

     

  • Key Performance Capabilities:

    • Up to 900 watts RMS power output (7136 model)
    • Small signal response up to 400 kHz
    • User-adjustable precision DC offset
    • User-adjustable current limit: 1A to 25A
    • 4-quadrant operation
    • AC/DC coupled

     

  • Key Performance Capabilities:

    • Up to 900 watts RMS power output (7136 model)
    • Small signal response up to 400 kHz
    • User-adjustable precision DC offset
    • User-adjustable current limit: 1A to 25A
    • 4-quadrant operation
    • AC/DC coupled

     

  • 1.5GHz & 3GHz

    • 1.5GHz and 3GHz models
    • Internal DDS baseband generator provided as logic LF output
    • Compatible with previous Aim-TTi RF generators
    • Phase noise <-117dBc/Hz (typ.) at 1GHz output 10kHz offset
    • Extensive analog and digital modulations
    • Amplitude range of -127dBm to +13dBm
    • High signal purity
    • Fast amplitude and/or frequency sweeps

     

  • Dual Measurement Bench Multimeter with USB and optional RS232, LXI/LAN and GPIB interfaces

    1908 Digit Multimeter Series

     

    • Affordable 5.5 digit high performance bench/portable multimeter
    • Dual display and dual measurement capability
    • Mains power or Internal rechargeable batteries for true portability
    • High accuracy and resolution: 0.02%, 1µV, 0.1µA, 1mΩ
    • True RMS AC, Frequency, capacitance and temperature measurements
    • Wide range of computing functions e.g. Ax + B
    • USB interface standard, RS232, LAN/LXI and GPIB optional

     

    • Affordable 5.5 digit high performance bench/portable multimeter
    • Dual display and dual measurement capability
    • Mains power or Internal rechargeable batteries for true portability
    • High accuracy and resolution: 0.02%, 1µV, 0.1µA, 1mΩ
    • True RMS AC, Frequency, capacitance and temperature measurements
    • Wide range of computing functions e.g. Ax + B
    • USB interface standard, RS232, LAN/LXI and GPIB optional

     

  • with analogue and digital control, USB, RS232, LAN (LXI) and GPIB

    • Versatile solution for direct testing of dc power sources and PFCs
    • Constant current, resistance, conductance and power modes
    • Wide voltage and current range, 10 to 500V and 0 to 16A
    • 400 watts continuous dissipation at 28°C (360W at 40°C)
    • High resolution and accuracy for level setting
    • Built-in transient generator with variable slew
    • Current monitor output for waveform viewing
    • Variable drop-out voltage for battery testing
    • High resolution backlit graphic LCD with soft key control
    • Analogue remote control of levels and TTL control of on/off and transient switching
    • Front and rear input terminals
    • Load inputs rated to CAT II (300V)
    • Full bus control via USB, RS232, GPIB and LXI compliant LAN interfaces