1 800 665 7301 | info@tmetrix.com

  • Single-phase, 2U, industrial amplifier/battery simulator

    • Bench-sized
    • Powered from 120V/230VAC
    • Source and Sink (4 quadrant)
    • Rugged Design
    • 3-Year, No-Fault Warranty

    Key Performance Capabilities:

    • Drop outs and surges as fast as 1.2µs
    • Small signal response up to 1 MHz
    • 13.5 VDC at up to 28A
    • Field-selectable ±40V, 75V or 150V potential

     

  • The First Wide-Bandwidth, High-Power Digital Amplifiers

    • Max Continuous Output Current: 300A RMS
    • Surge Rating: 2X power at up to 400 VP or 750A
    • Apparent Power Rating: Up to 5X continuous power rating atup to 400 VP or 750A
    • Supply Voltage: Three-phase, 208V ±10%, 60A, 50/60 Hz; 400V ±10%, 15A version available.
    • Dimensions (HxWxD): 36.5 x 21.0 x 30.75 inches (92.7 x 53.3 x 78.1 cm)
    • Weight: Appx. 540 lbs. (244.9 kg)

     

  • The DCP-X probe is designed for engineers and scientists in device characterization, R&D, and testing, offering highly accurate and repeatable on-wafer electrical measurements (IV, CV, LFN). It uses MEMS technology to measure advanced devices (2, 3, 5 nm) on various pad materials, micro-bumps, and pads as small as 20 μm, reducing the need for retesting and cleaning while covering the full thermal range at lower testing costs. Compared to traditional probes, the DCP-X provides 1000x lower contact resistance, minimal skate, and over 500,000 contact cycles, ensuring precise measurements and longer probe life.

  • The EME Guard Plus is a lightweight and robust personal protection monitor designed to ensure the safety of workers operating near electromagnetic field (EMF) emitters such as antennas, radars, and base stations. With a frequency range of 1 MHz to 40 GHz, this device continuously monitors and records EMF exposure levels while providing immediate audio, visual, and vibrating alerts when exposure exceeds predefined safety thresholds. Customizable alarm settings and a triaxial isotropic probe ensure accurate and reliable measurements.

     

  • The EME Guard XS Radar is a state-of-the-art RF safety monitor, specifically designed for workers operating near radar transmitters and antennas. With its isotropic tri-axis E-field sensors, this compact device provides continuous EMF monitoring over a frequency range of 1 MHz to 40 GHz, including short pulsed signal detection. Equipped with audio and visual alarms, it alerts users instantly when EMF exposure exceeds predefined safety thresholds, creating a safer working environment for military, aviation, and telecom personnel.

     

  • Solutions For:

    •  Accurate measurement with tri-axis sensors
    • Instant audio and visual alarm
    • Robust, reliable and user-friendly
    • Covers 5G / 6G bands, measuring up to 71 GHz

    User profile:

    • Persons working near antennas including installation and maintenance workers, broadcast, PMR and mobile phone operators or regulatory body employees

    Measurement capabilities:

    • Continuous monitoring of Electromagnetic Field levels with isotropic tri-axis E-field sensors
    • EMF Level indicated by a LED color scale
    • Audio and visual alarms triggered when EMF exceeds the reference level
  • The EMI 64k software allows to embed the TDEMI systems in a fully automated test environment.

    • Full automation of EMI testing according to all commercial and military standards
    • Automated control of turntable, antenna and other equipment
    • Height and Angular Scan
    • Procedures according to standards as well as customized procedures
    • Reducing the cost for EMC and communication testing and certification by tailored packages

     

  • The measurement system for all emission measurments in the frequency range 1 Hz – 44 GHz.

    • Frequency Range  1 Hz – 30MHz, 1GHz, 3GHz, 6GHz, 9GHz, 18GHz, 26GHz, 40 GHz and 44GHz
    • 225 MHz Real-time Analysis Bandwidth
    • Weighted Real-time Spectrogram up to 44 GHz
    • CISPR Bandwidths 200 Hz, 9 kHz, 120 kHz, 1 MHz
    • MIL/DO Bandwidths 10 Hz, 100 Hz, 1 kHz, 10 kHz, 100 kHz, 1 MHz

     

  • The measurement system for all emission measurments in the frequency range 1 Hz – 44 GHz.

    • Full compliance EMI Reciever according to standard CISPR 16-1· 1, ANSI C63.2, MIL->461, and DO·160
    • Spectrum Analyzer
    • Integrated LOW Noise Ampllfier (lNAI)
    • Integrated Preselect1on
    • Tradttional and FFT·based Mode
    • Automatic Stepped Attenuator
    • Ultra Low Noise Floor
    • Excellent spurious Performance
    • Real-time Spectrum Analyzer optional
    • Vast IQ-Bandwidth

     

  • TDEMI Mobile+. The ultra mobile EMI receiver – Emission measurements everytime, everywhere. Fully stand-alone operable.

    • Frequency Ranges 10Hz – 1GHz, 3GHz, 6GHz or 7GHz
    • 16000x faster than conventional receivers
    • Super compact design and 12V supply
    • 225 MHz fully gapless real-time analysis bandwidth
    • Weighted Real-time Spectrogram

     

  • Ultra High Performance RT Spectrum Analyzer. Ultrafast EMI Measurements.

    • Frequency Range from 1 Hz up to 50 GHz
    • 225 MHz Real-time analysis bandwidth
    • 100 dB Dynamic Range
    • Ultrahigh performance preselection in all modes
    • Up to 510 MHz Real-time IQ-Analysis bandwidth
    • Ultra High Performance Spectrum Analyzer

     

     

  • The TESLA300 Advanced On-Wafer Power Semiconductor Probe System is an integrated high-power test solution that enables the collection of accurate high-voltage and high-current measurement data up to 3 kV (triaxial) / 10 kV (coaxial) and 200 A (standard) / 600 A (high current), with complete operator safety.

    • Vector Network Analyzer (option up to 26.5GHz)
    • WinCal XE calibration software
    • Uses best measurement practices for optimized measurements
    • Known measurement accuracy traced back to independent standards
    • Supported by the measurement experts to make you successful
    • Best in class RF performance
    • Small benchtop footprint
    • Industry standard calibration techniques
    • Extended 2 Year warranty on FormFactor products for educational customers

     

    • Re-configurable for DC, RF, mmW, FA, WLR and more
    • table and repeatable measurements over a wide thermal range
    • Moisture-free, light-tight and EMI-shielded test environment with MicroChamber® technology
    • Minimize AC and spectral noise
    • Manual 3-axis stage with ergonomic controls
    • Fast, accurate “hands on” wafer positioning
    • Quick, safe, and comfortable wafer access

     

    • Comfortable and ergonomic operation
    • Thermal range ambient to +300°C
    • RF/microwave device characterization, FA and design debug
    • Seamless integration between Velox and analyzers/measurement software
    • Complete solutions using probe positioners and probe cards
    • Achieve unsurpassed RF/mmW measurement and calibration accuracy with integrated RF tools and WinCal
    • Shortest signal path test integration for accurate, thermally stable, and low-error data collection
    • Powerful automation tools, reduce total test time on wafers, singulated dies, and modules
    • Faster time to first data for standard and “hard to test” devices such as thin wafer, small pad and high power
    • Advanced 4-axis semi-automatic stage for accurate positioning and repeatable probe-to-pad contact

     

  • Genius Education Kits Overview