1 800 665 7301 | info@tmetrix.com

    • Advanced semiconductor technology
    • High-quality construction
    • Rapid capacitor and pulse-forming network charging
    • Compact and lightweight design
    • Simple parallel operation for higher power needs
    • Compatible with worldwide input voltages and frequencies
    • Fully adjustable output voltage
    • Comprehensive remote control interface

     

  • High-Speed Current Control: No dynamic overshoot or oscillation
    High Slew-Rate: Up to 30A/*s for fast load changes
    Low Voltage Operation: Stable operation with no turn-on delay
    Multi-Functional: Seven load modes and four operating modes
    Parallel Operation: Up to 10kW with 10 units
    User-Friendly Interface: Built-in USB and optional IEEE interfaces
    Compliance: EN61010-1 compliant with a two-year warranty

  • Karis SRK Series Server Cabinets are a reliable way to keep sensitive electronics safe. The professional design features a ventilation rate of more than 74%, providing adequate cooling for the entire system. Karis’s server cabinets will make integrating your data center or data closet fast and easy.

    • Curved locking front door with ventilation rate above 80%
    • Split locking rear door with ventilation rate above 80%
    • Horizontally split locking side panels make access easy
    • Two heights, two depths, and two widths available
    • Rear vertical cable managers (two) include
    • Square hole mounting rails are adjustable front to rear
    • Grounding kit included
    • Levelers and heavy duty casters come standard
    • Full range of optional accessories
    • 5 year warranty

     

  • Key Performance Capabilities:

    • Slew rates up to 60 V/µsec.
    • Up to 240A DC at +50VDC or –50VDC (4301-240 configuration).
    • Can provide pulses of up to 800 amps at voltages of up to ±100V (4301-240 configuration).
    • Adjustable compensation allows the system to maintain a 50V/2 µsec rise-time over a wide range of current outputs.

     

  • Key Performance Capabilities:

    • Bandwidth: DC to 50 kHz
    • Voltage: 0 to 250 VRMS; 0 to 350 VDC
    • Current: 100 to 500 ARMS
    • Distortion: 0.1%
    • Power: 4 kW to 20 kW*Power levels up to 5X rated power when driving reactive loads
    • High power efficiency and density

    *Models available with output from 4 kW to 20 kW (capable of up to 125 kVA).

     

  • Key Performance Capabilities:

    • 4-Quadrant – Can source and sink current
    • ±80V – DC supply for 12V to 48V systems; meets 80V surge requirements
    • 300 kHz Sine – DC ripple tests for all major standards
    • 3µs Rise Time – Exceeds surge and dropout slew rate requirements
    • 3mΩ DC Source Impedance – Out-performs ISO 7637-2 requirements
    • Supports ground reference and supply offset testing required for ISO 16750-2 Sect. 4.8 and other similar standards

     

  • Key Performance Capabilities:

    • Up to 900 watts RMS power output (7136 model)
    • Small signal response up to 400 kHz
    • User-adjustable precision DC offset
    • User-adjustable current limit: 1A to 25A
    • 4-quadrant operation
    • AC/DC coupled

     

  • Key Performance Capabilities:

    • Up to 900 watts RMS power output (7136 model)
    • Small signal response up to 400 kHz
    • User-adjustable precision DC offset
    • User-adjustable current limit: 1A to 25A
    • 4-quadrant operation
    • AC/DC coupled

     

    • Proven member of a modular Power Module family, more than 800 units are in service
    • Precision-regulated Bi-Polar output provides up to +12 to -12 Amps for Magnet loads.
    • Smooth operation through zero amps output current, no “Crossover” problems.
    • All 2510 MCOR12 Power Modules are identical and interchangeable.
    • Has two high-precision measurements of output current;
      • one is used to close the regulation control loop,
      • provides an independent monitoring signal to the Crate Interface Card.
    • Fault sensing circuitry in the module sets a Fault Latch which inhibits the output.
    • A (momentary) Sync input signal inhibits MOSFET switching when it is active (high);
      • this eliminate switching noise .
      • reduces power line noise during sensitive analog signal measurements.

     

    • Proven member of a modular Power Module family, more than 800 units are in service
    • Precision-regulated Bi-Polar output provides up to +30 to -30 Amps for Magnet loads.
    • Smooth operation through zero amps output current, no “Crossover” problems.
    • All 2510R30 MCOR30 Power Modules are identical and interchangeable
      • Programming Card is plugged into the replacement module.
    • Each channel has a critically-damped, LC noise filter with a cut-off frequency of about 8 kHz.
    • A 16-pin front panel diagnostics connector taps onto major circuit nodes which enables quick “inthe-crate” fault evaluation

     

    • 2U Chassis – 19″ rack mount 3.48” Height, 9.60” Depth and Weight 6lb.
    • Power 120V AC 60Hz
    • Washable front removable air filter
    • Ball Bearing AC fans provide 330 CFM
    • Dual plenum design
    • Cooling for 160mm,220mm depth modules
    • Diverts lower warmed air to rear of Cabinet
    • RM option diverts lower air to front of Cabinet

     

    • accommodate these control schemes
    • total control system interface on a single VME-standard card
    • occupies the left-most slot of the crate
    • monitoring voltage reference inputs, output voltages and fault conditions
    • standard VMEbus-compatible 6U by 220 mm board installed
    • Eurocard crate
    • Two 96-pin I/O connectors

     

  • MCOR Modules

    MCOR 2/6/9/12

    Each module can be customized to provide maximum outputs of 2 amps, 6 amps, 9 amps, and 12 amps. Up to 16 of these can fit in a single 6U VME style crate.

    MCOR 30

    Each module can provide a maximum output 30 amps. Up to 8 of these can fit in a single 6U VME style crate.

    • provides precision bi-polar output currents
    • minimal zero-cross over distortion
    • 19” rack mounted 6U x 220 mm crate
    • crate has 17 slots; 16 (slot 0 thru 15)
    • connectors
      • J1 (ExtIntlk),
      • J2 (CrateOK),
      • J3 (Input Reference Voltages),
      • J4 (Output Monitors), and
      • J9 (Bitbus)