1 800 665 7301 | info@tmetrix.com

  • Dual Measurement Bench Multimeter with USB and optional RS232, LXI/LAN and GPIB interfaces

    1908 Digit Multimeter Series

     

    • Affordable 5.5 digit high performance bench/portable multimeter
    • Dual display and dual measurement capability
    • Mains power or Internal rechargeable batteries for true portability
    • High accuracy and resolution: 0.02%, 1µV, 0.1µA, 1mΩ
    • True RMS AC, Frequency, capacitance and temperature measurements
    • Wide range of computing functions e.g. Ax + B
    • USB interface standard, RS232, LAN/LXI and GPIB optional

     

    • Affordable 5.5 digit high performance bench/portable multimeter
    • Dual display and dual measurement capability
    • Mains power or Internal rechargeable batteries for true portability
    • High accuracy and resolution: 0.02%, 1µV, 0.1µA, 1mΩ
    • True RMS AC, Frequency, capacitance and temperature measurements
    • Wide range of computing functions e.g. Ax + B
    • USB interface standard, RS232, LAN/LXI and GPIB optional

     

  • with analogue and digital control, USB, RS232, LAN (LXI) and GPIB

    • Versatile solution for direct testing of dc power sources and PFCs
    • Constant current, resistance, conductance and power modes
    • Wide voltage and current range, 10 to 500V and 0 to 16A
    • 400 watts continuous dissipation at 28°C (360W at 40°C)
    • High resolution and accuracy for level setting
    • Built-in transient generator with variable slew
    • Current monitor output for waveform viewing
    • Variable drop-out voltage for battery testing
    • High resolution backlit graphic LCD with soft key control
    • Analogue remote control of levels and TTL control of on/off and transient switching
    • Front and rear input terminals
    • Load inputs rated to CAT II (300V)
    • Full bus control via USB, RS232, GPIB and LXI compliant LAN interfaces

     

  • with analogue and digital control, USB, RS232, LAN (LXI) and GPIB

    • Versatile solution for direct testing of dc power sources and PFCs
    • Constant current, resistance, conductance and power modes
    • Wide voltage and current range, 10 to 500V and 0 to 16A
    • 400 watts continuous dissipation at 28°C (360W at 40°C)
    • High resolution and accuracy for level setting
    • Built-in transient generator with variable slew
    • Current monitor output for waveform viewing
    • Variable drop-out voltage for battery testing
    • High resolution backlit graphic LCD with soft key control
    • Analogue remote control of levels and TTL control of on/off and transient switching
    • Front and rear input terminals
    • Load inputs rated to CAT II (300V)
    • Full bus control via USB, RS232, GPIB and LXI compliant LAN interfaces

     

    • Multiple ranges on each output for wider voltage/current choice
    • Four independent 105W full performance outputs
    • Instant individual on/off control plus sequencable multi on/off
    • Simultaneous display of meters and settings for all outputs
    • Up to 250 settings memories for individual or multiple outputs
    • Instant access to voltage/current setting for any output
    • USB, RS-232, LXI compliant LAN, and GPIB* interfaces (P versions)
    • USB, RS-232, LXI compliant LAN, and GPIB* interfaces (P versions)
      Duplicate power and sense terminals at rear (P versions)

     

    • Frequency up to 160MHz, 15 digits or 1µHz resolution
    • Wideband noise generator | high resolution pulse generator
    • Arbitrary waveforms up to 16bits at 800MS/s
    • Comprehensive internal/external digital and analog modulations
    • Two identical channels with phase control, coupling and tracking
    • USB and LXI compliant LAN interfaces, plus optional GPIB interface

     

  • Pulse and Universal Generator with 25 or 50MHz models, single or dual channel

    TGP3100 Series

     

    • Arbitrary waveforms at 800MS/s sampling rate and 16-bit vertical resolution
    • Extensive internal/external modulation of all waveform types
    • Linear and logarithmic sweeps of all waveform types
    • Front panel mounted USB Flash drive interface
    • GPIB (option), USB and LXI compliant LAN interfaces
    • Triggered (burst count) or gated operation using internal or external trigger sources

     

    • Arbitrary waveforms at 800MS/s sampling rate and 16-bit vertical resolution
    • Extensive internal/external modulation of all waveform types
    • Linear and logarithmic sweeps of all waveform types
    • Front panel mounted USB Flash drive interface
    • GPIB (option), USB and LXI compliant LAN interfaces
    • Triggered (burst count) or gated operation using internal or external trigger sources

     

    • Arbitrary waveforms at 800MS/s sampling rate and 16-bit vertical resolution
    • Extensive internal/external modulation of all waveform types
    • Linear and logarithmic sweeps of all waveform types
    • Front panel mounted USB Flash drive interface
    • GPIB (option), USB and LXI compliant LAN interfaces
    • Triggered (burst count) or gated operation using internal or external trigger sources

     

    • Arbitrary waveforms at 800MS/s sampling rate and 16-bit vertical resolution
    • Extensive internal/external modulation of all waveform types
    • Linear and logarithmic sweeps of all waveform types
    • Front panel mounted USB Flash drive interface
    • GPIB (option), USB and LXI compliant LAN interfaces
    • Triggered (burst count) or gated operation using internal or external trigger sources

     

    • Sine frequency up to 240MHz with 1µHz resolution
    • Up to 100MHz high resolution pulse generator
    • Arbitrary waveforms up to 16bits at 800MSa/s
    • Wideband noise generator

     

    • Frequency Range 10 Hz – 1GHz, 3GHz or 6GHz
    • 4000x faster in your pre-certifcation work
    • compact design and +12V power supply
    • 162.5 MHz full gapless real-time analysis bandwidth
    • Weighted Real-time Spectrogram

     

    • requency Range from DC up to 40 GHz
    • 685 MHz Real-time analysis bandwidth
    • Dynamic range of more than 100 dB
    • Multi-GHz real-time scanning up to 40 GHz
    • all 6dB RBWs acc. to CISPR, MIL, DO, ANSI, FCC
    • fastest super-heterodyn receiver on the planet

     

    • compact and completely modular design
    • high effectiveness in all operation modes, few requirements on building infrastructure
    • ability to use an existing liquid cooling system directly
    • optional matched liquid-to-air cooling unit TC.LAE available
    • possibility of upgrading to systems of up to 1 MVA
    • high level of system dynamics, ≤ 5 kHz modulation bandwidth
    • non-restrictive capability of refeeding in the Q4 operation mode
    • possibility of operating as an autonomous 4-Q and 3-phase quasi-analogue amplifier
    • possibility of “Hardware-in-the loop”-operation (HIL mode)
    • user friendly application software with pre-configured test patterns
    • possibility of integrating into a complete SAS simulation and test system
    • galvanic isolation available as an option without derating the simulator port data