1 800 665 7301 | info@tmetrix.com

    • Current measurement from insulated probing of conductor
    • Suitable for observation and measurement of current in PCB tracks, component leads and ground planes
    • Wide dynamic range of 10mA to 20A peak to peak
    • Wide bandwidth of DC to 5MHz
    • Low noise figure equivalent to <6mA rms at full B/W
    • Safety rated to 300V Cat II (600V Cat 1)
    • Suitable for connection to any oscilloscope
    • High accuracy general purpose H-field probe
    • Converts to ‘closed magnetic circuit’ current probe

     

    • Customizable & savable test setups
    • Program & Datalog Storage
    • User Defined Temperature Limits
    • Local & Remote Operations
    • LabView™ drivers
    • IEEE-488, RS232 ports

     

     

    • 20 Amp Operation: Full performance with 20 amp service
    • Automatic Power Reduction: Reduces power usage during idle periods
    • Heat Only Mode: Reduces power usage when cold temperatures are not used
    • WhisperStream Technology: quieter, smooth-sounding operation, 56 dBA
    • Frost Free Test Environment: dry air purge for tester interface, prevents condensation:
      0.5 to 3scfm (0.25 to 1.5 l/s)
    • Heated Defrost: quickly removes moisture buildup from internal chiller
    • DUT Temperature Control : Proprietary control algorithm enables DUT temperature to be directly controlled
    • Transition Rate*
      -55 to +125°C, approx. 10 seconds
      125 to -55°C, approx. 10 seconds
    • System Airflow Output*
      4 to 18scfm (1.9 to 8.5 l/s) Continuous
    • Temperature Range*
      -80 to +225°C (60Hz) No LN2 or LCO2 Required

     

    • High reliability thermal cycling without thermoelectric modules
    • Temperature range: -65 to 175°C
    • Cooling power:
      • 40W at -40°C for lower power devices
      • 55W at -55°C and 120W at -40°C.
    • Transition rate: up to <35 sec over 25 to -40°C
    • Easy and secure thermal connection to in-circuit or test socked DUT
    • Touch-screen controller: user-programmable temperatures, graphing, data logging
    • Communications options: Ethernet, USB, IEEE, RS232

     

  • -60° to +200°C

    • Economy model with high thermal capacity
    • Precise temperatures with fast transitions from -60 to 200°C
    • No annual leak testing required per EU 517/2014 F-Gas Regulation
    • Effective testing and conditioning of electronic components, boards, and modules
    • Available for 50 and 60Hz operation
    • No need for Liquid Nitrogen (LN2) or Liquid Carbon Dioxide (LCO2)
    • Remote communications and set up and touch screen operation
    • User Defined Temperature Limits

     

     

  • The new G5.RSS series features

    • High control dynamics
    • An exceptional accuracy
    • A nominal output voltage of up to 3000 VDC
    • A wide current-voltage range with an auto-ranging factor of 3.
    • You get the best value for your investment.

     

    • compact and completely modular design
    • high effectiveness in all operation modes, few requirements on building infrastructure
    • ability to use an existing liquid cooling system directly
    • optional matched liquid-to-air cooling unit TC.LAE available
    • possibility of upgrading to systems of up to 1 MVA
    • high level of system dynamics, ≤ 5 kHz modulation bandwidth
    • non-restrictive capability of refeeding in the Q4 operation mode
    • possibility of operating as an autonomous 4-Q and 3-phase quasi-analogue amplifier
    • possibility of “Hardware-in-the loop”-operation (HIL mode)
    • user friendly application software with pre-configured test patterns
    • possibility of integrating into a complete SAS simulation and test system
    • galvanic isolation available as an option without derating the simulator port data

     

  • Bidirectional (source & sink), Regenerative 0…65VDC to 0…1500VDC, 20kW up to 1.5 MW 

    • cell system nominal voltage and type of chemistry
    • number of cells
    • internal resistance and associated parameters
    • cell temperature progression
    • allowed current
    • charge efficiency
    • energy computing and management facilities
    • time-dependent and functional dependent parameters

     

    • Setting of operational parameters for each output phase: (frequency, phase, voltage, basic waveform)
    • Defining functional blocks enabling a wide variety of modulation capabilities
    • Defining, editing and storing of even complex and long test sequences
    • Preview window for output voltage waveforms
    • LC load mode, definition of complex equivalent circuits
    • Hand drawing curve tool and FOURIER tool (harmonics synthesis)
    • TC.ACS provides an extensive safety concept in order to detect unwanted or off-limit conditions very quickly and to initiate controlled limiting or even a shutdown.

     

    • compact and completely modular design
    • high effectiveness in all operation modes, few requirements on building infrastructure
    • ability to use an existing liquid cooling system directly
    • optional matched liquid-to-air cooling unit TC.LAE available
    • possibility of upgrading to systems of up to 1 MVA
    • high level of system dynamics, ≤ 5 kHz modulation bandwidth
    • non-restrictive capability of refeeding in the Q4 operation mode
    • possibility of operating as an autonomous 4-Q and 3-phase quasi-analogue amplifier
    • possibility of “Hardware-in-the loop”-operation (HIL mode)
    • user friendly application software with pre-configured test patterns
    • possibility of integrating into a complete SAS simulation and test system
    • galvanic isolation available as an option without derating the simulator port data

     

    • 16K Video Generator & Analyzer
    • Dolby Vision™, HDR 10 and HDR 10+
    • validating DP 1.4a & DP 2.0 Link Layer on DP Sinks and Sources
    • Power Input +12 Vdc (AC/DC converter included)
    • Module Size/Weight TBD for Weight and Size

     
    Unigraf_1.PNG

     

    • Compact sized DisplayPort™ 1.2 compliant Reference Sink
    • HBR2 and MST capable Sink and Branch device
    • Cerified as the platform for DP 1.2 LL CTS Ext1 tests
    • Optional MST Debug panel and AUX Channel Monitor
    • Debug and Test Controller GUI enables monitoring and previewing any MST stream
    • User programmable EDID and DPCD

     

    •  HDMI 2.1 Test Equipment (FRL)
    • Enhanced Gaming Features (VRR, ALLM)
    • FEC, Forward Error Correction
    • HDCP 2.2 & HDCP 2.3 support  TMDS Support
    • Dolby Vision™ Test Tool
    • 8K@60 fps Support (12 Gbps/channel)
    • eARC Support (end of 2019)
    • DSC Support (ESTIMATED 2020)
    • UCD Console GUI for debugging
    • High level API for easy integreation

     

    • Automated tests for USB-C™ DisplayPort™ Alt Mode
    • Electrical Test to verify whole USB-C connector with single cable insert
    • Test USB 2.0 and USB 3.0
    • 4K@60 support
    • Easily set test parameters with provided Software
    • Easily run tests from the commandline
    • Unigraf’s Test System Interface (TSI) Support
    • Third Part Test Management Software
    • Support e.g. NI TestStand Support

     

    • UHD / 4K compliant test equipment
    • HDMI 2.0 and DP 1.2 input and output in one unit
    • DCP Approved HDCP 2.3 CTS Test Tool
    • HDCP 1.3 and HDCP 2.3 support
    • Sink and source video, audio and configuration parameters
    • USB 3.0 connected
    • UCD Console GUI for debugging
    • High level API for easy integration

     

    • Test DP over USB-C video and audio
    • Test USB-C Power Delivery with DP Alt Mode
    • DCP Apporved HDCP 2.3 CTS Tests
    • Verify interface signal continuity
    • 4K@60 support
    • HDCP 1.3 and HDCP 2.3 support
    • Capture video and audio, monitor and control interface parameters
    • USB signal pass-thru
    • UCD Console GUI for debugging
    • High level API for easy integration