1 800 665 7301 | info@tmetrix.com

    • Customizable & savable test setups
    • Program & Datalog Storage
    • User Defined Temperature Limits
    • Local & Remote Operations
    • LabView™ drivers
    • IEEE-488, RS232 ports

     

     

    • 20 Amp Operation: Full performance with 20 amp service
    • Automatic Power Reduction: Reduces power usage during idle periods
    • Heat Only Mode: Reduces power usage when cold temperatures are not used
    • WhisperStream Technology: quieter, smooth-sounding operation, 56 dBA
    • Frost Free Test Environment: dry air purge for tester interface, prevents condensation:
      0.5 to 3scfm (0.25 to 1.5 l/s)
    • Heated Defrost: quickly removes moisture buildup from internal chiller
    • DUT Temperature Control : Proprietary control algorithm enables DUT temperature to be directly controlled
    • Transition Rate*
      -55 to +125°C, approx. 10 seconds
      125 to -55°C, approx. 10 seconds
    • System Airflow Output*
      4 to 18scfm (1.9 to 8.5 l/s) Continuous
    • Temperature Range*
      -80 to +225°C (60Hz) No LN2 or LCO2 Required

     

  • Dual Measurement Bench Multimeter with USB and optional RS232, LXI/LAN and GPIB interfaces

    1908 Digit Multimeter Series

     

    • Affordable 5.5 digit high performance bench/portable multimeter
    • Dual display and dual measurement capability
    • Mains power or Internal rechargeable batteries for true portability
    • High accuracy and resolution: 0.02%, 1µV, 0.1µA, 1mΩ
    • True RMS AC, Frequency, capacitance and temperature measurements
    • Wide range of computing functions e.g. Ax + B
    • USB interface standard, RS232, LAN/LXI and GPIB optional

     

    • Affordable 5.5 digit high performance bench/portable multimeter
    • Dual display and dual measurement capability
    • Mains power or Internal rechargeable batteries for true portability
    • High accuracy and resolution: 0.02%, 1µV, 0.1µA, 1mΩ
    • True RMS AC, Frequency, capacitance and temperature measurements
    • Wide range of computing functions e.g. Ax + B
    • USB interface standard, RS232, LAN/LXI and GPIB optional

     

  • Bench/System DC Power Supply, PowerFlex Regulation, Smart Analog Controls Single or Dual Outputs, 360 to 840 watts, with/without Remote Interfaces
    • PowerFlex design gives variable voltage and current combinations within a maximum power range
    • Up to 60 volts and up to 20 amps
    • 180 watts or 420 watts maximum per output
    • Isolated outputs can be wired in series or parallel
    • Constant voltage or constant current operation
    • Settings Locking (S-Lock)
    • PowerFlex or fixed-range operation
    • Variable OVP trips
    • Selectable remote sense terminals
    • Compact quarter or half rack 3U case size
    • Isolated analogue remote control (CPX400SA only)
    • RS232, USB, GPIB & LXI compliant LAN (P models only)