1 800 665 7301 | info@tmetrix.com

  • Multi-Range DC Power Supply with digital control, 3 or 4 Outputs, 315 to 420W with/without Remote Interfaces

    • hree or four high performance outputs each with full functionality
    • Range switching gives variable voltage/current combinations
    • Shared power mode provides double power from a single output
    • Low output noise and ripple via linear final regulation
    • High setting resolution of up to 1mV and 0.1mA
    • Variable OVP and OCP trips on all outputs
    • 50 setting memories per output plus 50 linked memories
    • Selectable voltage tracking (isolated tracking)
    • Selectable current meter averaging
    • Switchable remote sense capability
    • Graphic LCD provides simultaneous output metering
    • Numeric or spin-wheel control of all parameters
    • Individual or combined output on/off control with programmable delay sequencing.
    • 3U half-rack case for bench or rack mounting (4U rack kit accessory available)
    • RS-232, USB and LAN (LXI) interfaces (P models), GPIB option
    • Duplicate power & sense terminals at rear (P models)

     

  • Multi-Range DC Power Supply Triple Outputs, 3 x 35V/3A 315W, No Interfaces

    • Three or four independent and full performance outputs
    • Simultaneous display of meters and settings for all outputs
    • Instant access to voltage/current setting for any output
    • Multiple ranges on each output for wider voltage/current choice
    • Instant individual on/off control plus sequencable multi on/of
    • Up to 250 settings memories for individual or multiple outputs

     

  • with 10MHz to 3.6 or 6.0GHz bandwidth options

    True hand-held battery powered RF spectrum analyzers.

    • 10MHz to 3600MHz or 6000MHz frequency range
    • Resolution bandwidths from 300Hz to 10MHz (1:3:10)
    • -120dBm typical noise floor at -40dBm ref. level/10kHz RBW
    • Measurement in dBm or dBµV, mV or µW
    • Zero span mode with AM and FM audio demodulation
    • Trace modes of normal, peak hold and trace average
    • Live, View and Reference traces in contrasting colours
    • Twin markers with readout of absolute & difference values
    • Smart marker movement with selectable peak tracking
    • Frequency counter with down to 10Hz resolution
    • Frequency presets and independent state storage
    • Auto-find automatically sets sweep parameters for the highest signal found
    • Unlimited storage for waveforms, set-ups and screens
    • User assignable file names, file stamping from real-time clock
    • USB interfaces for Flash drives and PC connection
    • Comprehensive status and context sensitive help screens
    • Rechargeable lithium ion battery giving more than 3 hours continuous operation from a charge
    • Smaller and lighter than other spectrum analyzers (weight only 0.56 kg)

     

  • DC Power Supply single output, 80V/50A 750W PowerFlex+, LAN & USB interfaces, GPIB Option

    • Wide range of voltage/current combinations
    • Up to 80V and up to 50A within the same power envelope
    • Low output ripple and noise of <3mV rms at full power
    • High setting resolution of 1mV
    • Analogue control interfaces for voltage and current
    • Bench or rack mounting, front and rear terminals
    • LAN (LXI), USB, GPIB interfaces (GPIB optional on QPX750SP)

     

    • 150kHz to 3GHz (TGR2053) and 150kHz to 1.5GHz (TGR2051) frequency range
    • High signal purity, phase noise <-117dBc/Hz (typical) at 1GHz output and 10kHz offset
    • Amplitude range of -127dBm to +13dBm
    • 0.1dBm amplitude setting resolution
    • Internal or external analogue modulations (AM, FM, PM)
    • Amplitude can be set in dBm, dBμV or in linear Volts.
    • Internal or external digital modulations – ASK, OOK, FSK, 3FSK, 4FSK, GFSK, MSK, GMSK, HMSK & PSK with U01 option
    • Modulation Synchronisation
    • Fast amplitude and/or frequency sweeps with comprehensive triggering
    • 5ms sweep settling time
    • 1ppm frequency accuracy, <1ppm drift in first year
    • Modulation waveform output on the rear panel
    • Internal waveforms include: Sine, Square, Ramp, Triangle, PRBS (various lengths) and user-defined pattern
    • Simple operation with the colour touch screen
    • Programmable via USB, LAN (LXI) and GPIB (optional), SCPI compatible
    • Compatible with previous Aim-TTi RF generators

     

  •  

    • Reliable and Repeatable solid state signal generation
    • Standard Internal/external pulse modulation
    • USB/Ethernet Control
    • 10 MHz external or internal reference
    • 100 Hz Frequency Resolution
    • Easily portable
    • Sized to fit into a single rack unit for ATE applications

     

  •  

    • Reliable and Repeatable solid state digital attenuation
    • Includes GUI, Windows and Linux SDK, LabVIEW driver
    • Programmable attenuation ramp and fading profiles
    • Operate multiple devices directly from a PC or self-powered hub
    • Easily portable USB powered device
    • USB and Ethernet control interfaces

     

  • HDO4000A oscilloscopes have 4 analog input channels, 12-bit resolution using Teledyne LeCroy’s HD4096 high-definition technology, up to 1 GHz of bandwidth and a compact form factor with a large 12.1” multi-touch display. They are ideal for debug and troubleshooting of power electronics designs, digital power management or power integrity analysis, automotive electronics systems, and deeply embedded or mechatronic designs.

     

  • The WaveSurfer 3000z has a 10.1″ capacitive touch display, the longest memory, and the deepest toolbox – all at an affordable price.

    • HD4096 technology provides 12-bit resolution all the time
    • 2ProBus input supports over 30 probes in 9 product categories
    • 3Long record capture of up to 25 Mpts
    • 412.1” 1280 x 800 HD capacitive touchscreen
    • 5Mixed-signal capability – debug complex embedded designs with integrated 16-channel mixed signal option
    • 6Easy connectivity with 2 USB 3.1 ports
    • 7MAUI with OneTouch user interface for intuitive and efficient operation

     

    • 15.6″ 1920 x 1080 capacitive touchscreen display
    • 24 analog input channels
    • 3ProBus input supports every Teledyne LeCroy probe
    • 4MAUI with OneTouch user interface for intuitive and efficient operation
    • 5Q-Scape multi-tab display architecture
    • 6Up to 250 Mpts of acquisition memory
    • 7HD4096 technology – 12 bits all the time
    • 8Buttons/indicators color-coded to associated waveform on display
    • 9Use cursors and adjust settings without opening a menu
    • 10Mixed Signal capability with 16 integrated digital channels
    • 116 USB 3.1 ports (2 front, 4 side)

     

    • HD4096 technology provides 12-bit resolution up to 8 GHz and 20 GS/s
    • Up to 5 Gpts of acquisition memory enables detailed viewing of long events
    • 15.6” 1900 x 1080 Full HD capacitive touchscreen
    • ProBus2 input supports up to 8 GHz bandwidth while maintaining support for legacy ProBus probes
    • MAUI with OneTouch user interface for intuitive and efficient operation
    • Waveform Control Knobs – Control channel, zoom, math and memory traces with the multiplexed vertical and horizontal knobs
    • Color-coded panel indicators – Trigger, horizontal and vertical indicator colors correspond to the associated waveform on the display
    • Cursor/Adjust Knobs – Enable and position cursors or adjust settings and parameters without opening a menu
    • Mixed Signal Capability – Debug complex embedded designs with integrated 16-channel mixed signal capability
    • Easy connectivity with seven USB 3.1 ports (3 front, 4 side) and UHD (4k) HDMI and DisplayPort outputs

     

    • Eye diagram (a), eye mask failure (b) and IsoBER eye opening analysis (c)
    • Jitter spectrum (a) with noise floor display (b) and inverse FFT of the periodic jitter (c)
    • Data dependent jitter (DDj) plot for each bit in synch with pattern (a) and with histogram (b)
    • Time interval error (TIE) jitter track analysis
    • Jitter histograms (a) with bathtub curves (b) and CDF plot (c)
    • Intersymbol interference (ISI) plots pinpoint bit sequences that have high ISI and are sources of bit errors
    • Jitter measurements table with full details for one or more “lanes” plus reference

     

    • 15.6” 1920 x 1080 capacitive touchscreen display
    • 8 analog input channels
    • ProBus input supports every Teledyne LeCroy probe
    • MAUI with OneTouch user interface for intuitive and efficient operation
    • Q-Scape multi-tab display architecture
    • Up to 5 Gpts of acquisition memory
    • HD4096 technology – 12 bits all the time
    • Buttons/indicators color-coded to associated waveform on display
    • Use cursors and adjust settings without opening a menu
    • Mixed Signal capability with 16 integrated digital channels
    • 6 USB 3.1 ports (2 front, 4 side)
    • HDMI and DisplayPort – supports 4K (4096 x 2304) external monitor
    • Removable SSD (standard)
    • View 16 channels on one display with OscilloSYNC
    • Reference Clock Input/Output for connecting to other equipment
    • USBTMC over USB 3.1 for fast data offload

     

    • S-parameters DC to 40 GHz, single-ended and mixed-mode
    • Impedance Profile with <1 mm resolution, differential and common-mode
    • Internal, automatic OSLT calibration
    • USB-connected, small, lightweight
    • Flexible display of the measurements
    • Remove effects from fixtures, connectors and cables
    • Emulate eye diagrams with CTLE, DFE and FFE equalization
    • Advanced jitter analysis

     

    • 4/8 analog channels + 1 external trigger
    • Analog channel bandwidth: up to 2 Ghz; real-time sampling rate of up to 10 GSa/s
    • Vertical resolution: 12-bits
    • Low noise floor: 153 μVrms at full bandwidth of 2 GHz
    • New generation of high speed display technology:
      • Waveform capture rates up to 170,000 wfm/s (normal mode), and 750,000 wfm/s (sequence mode)
      • Supports 256-level intensity grading and color temperature display modes
      • Memory depth up to 500 Mpts/channel
      • Digital trigger system
    • Intelligent trigger: Edge, Slope, Pulse, Window, Runt, Interval, Dropout, Pattern, Qualified, Nth edge, Setup/hold, Delay and Video (HDTV supported)
    • Serial bus triggering and decoder, supports protocols I2C, SPI, UART, CAN, LIN, CAN FD, FlexRay, I2S, MIL-STD-1553B, SENT and Manchester as standard
    • Segmented acquisition (Sequence) mode, dividing the maximum record length into multiple segments (up to 80,000), according to trigger conditions set by the user, with a very small dead time between segments to capture the qualifying event
    • History waveform record (History) function, the maximum recorded waveform length is 80,000 frames
    • Automatic measurements on 50+ parameters, supports statistics with histogram, track, trend, Gating measurement, and measurements on Math, History, Memory and Ref
    • 4 Math traces (8 Mpts FFT, addition, subtraction, multiplication, division, integration, differential, square root, etc.), supports formula editor