1 800 665 7301 | info@tmetrix.com

  • Multiple Bandwidth Options: 100 MHz, 200 MHz, and 350 MHz
    Fast Sampling Rate: Up to 2 GS/s (interleaved) for high-speed signal acquisition
    Extended Memory Depth: Up to 28 Mpts per channel for capturing intricate signal variations
    Serial Bus Trigger and Decode: Built-in support for I2C, SPI, UART, RS232, CAN, LIN
    Waveform Sequence Recorder: Capture and playback up to 80,000 recorded waveforms
    Advanced Triggering System: Includes Edge, Slope, Pulse Width, Window, Runt, Interval, and Pattern triggers
    Multi-Mode Display: Supports color temperature mapping and intensity grading for signal clarity
    MSO Upgrade Option: 16 digital channels available for mixed-signal debugging (on 4-channel models)
    Connectivity: USB, LAN, and external trigger output for remote data transfer and PC control

     

    • Bandwidth Options: 100 MHz, 200 MHz, 350 MHz, and 500 MHz.
    • Sampling Rate: Up to 2 GS/s (1 GS/s per channel in four-channel mode).
    • Memory Depth: Up to 200 Mpts in interleaved mode for extended signal capture.
    • High-Speed Capture: Waveform update rates of 120,000 wfm/s in standard mode and up to 500,000 wfm/s in sequence mode.
    • Advanced Triggers: Edge, Slope, Pulse Width, Window, Runt, Interval, Dropout, Pattern, and Serial triggering.
    • MSO Functionality: Optional 16 digital channels for mixed-signal analysis.
    • Waveform Recorder: History Mode allows users to store and replay up to 90,000 waveforms.
    • Comprehensive Math Functions: Includes FFT, differentiation, integration, and enhanced resolution modes.
    • 256-Level Intensity Grading: Color temperature display for identifying rare signal events.
    • Connectivity: USB Host, USB Device, LAN, and External Trigger support for seamless data transfer and remote control.

     

    • High Bandwidth & Sampling Rate: Models available in 200 MHz, 350 MHz, 500 MHz, and 1 GHz with up to 5 GS/s sample rate.
    • Deep Memory Capture: Up to 250 Mpts in interleaved mode, allowing detailed waveform analysis.
    • Advanced Triggering & Waveform Capture: Zone Triggering, History Mode (100,000 waveforms), and a waveform capture rate of 500,000 wfm/s.
    • Math & Measurement Functions: 9 basic math functions (FFT, addition, subtraction, multiplication, division, etc.) and 50+ automatic measurement parameters.
    • Bode Plot & Power Analysis: Standard features include Bode Plot for frequency response testing and comprehensive power analysis for applications like power quality assessment, current harmonics, inrush current, and switching loss.
    • Mixed Signal Debugging: Optional 16-channel MSO capability for digital signal acquisition.
    • Connectivity & Remote Access: USB, LAN, and embedded web server for remote control and data analysis.

     

    • Available in 4.5-digit (60,000 count) and 6.5-digit (2,200,000 count) resolutions.
    • Wide measurement range:
      • DC Voltage: Up to 1000V
      • AC Voltage: Up to 750V (True RMS)
      • Current: 10A (AC/DC)
      • Resistance: 100MΩ (2-wire/4-wire)
      • Capacitance: 2nF – 100mF
      • Temperature measurements with TC and RTD sensor support.
    • High-speed measurements:
      • T3DMM4-5: 150 readings per second
      • T3DMM6-5: 10,000 readings per second
    • Advanced mathematical functions such as Max, Min, Standard Deviation, dBm/dB, Relative Measurement, Pass/Fail Analysis, and Histograms.
    • Connectivity: USB Device, USB Host, and LAN for remote operation via SCPI commands.
    • Data Storage: 1GB NAND flash memory for saving configuration files and test data.
    • Built-in cold junction compensation for accurate temperature measurements.
    • File management system supporting U-disc and local storage for convenient data access.
    • Comprehensive user interface with a dual-display system for easy navigation.
    • Automatic measurement functions, including statistical analysis, gating, and reference functions.

     

    • Customizable & savable test setups
    • Program & Datalog Storage
    • User Defined Temperature Limits
    • Local & Remote Operations
    • LabView™ drivers
    • IEEE-488, RS232 ports

     

     

    • 20 Amp Operation: Full performance with 20 amp service
    • Automatic Power Reduction: Reduces power usage during idle periods
    • Heat Only Mode: Reduces power usage when cold temperatures are not used
    • WhisperStream Technology: quieter, smooth-sounding operation, 56 dBA
    • Frost Free Test Environment: dry air purge for tester interface, prevents condensation:
      0.5 to 3scfm (0.25 to 1.5 l/s)
    • Heated Defrost: quickly removes moisture buildup from internal chiller
    • DUT Temperature Control : Proprietary control algorithm enables DUT temperature to be directly controlled
    • Transition Rate*
      -55 to +125°C, approx. 10 seconds
      125 to -55°C, approx. 10 seconds
    • System Airflow Output*
      4 to 18scfm (1.9 to 8.5 l/s) Continuous
    • Temperature Range*
      -80 to +225°C (60Hz) No LN2 or LCO2 Required

     

    • High reliability thermal cycling without thermoelectric modules
    • Temperature range: -65 to 175°C
    • Cooling power:
      • 40W at -40°C for lower power devices
      • 55W at -55°C and 120W at -40°C.
    • Transition rate: up to <35 sec over 25 to -40°C
    • Easy and secure thermal connection to in-circuit or test socked DUT
    • Touch-screen controller: user-programmable temperatures, graphing, data logging
    • Communications options: Ethernet, USB, IEEE, RS232

     

  • -60° to +200°C

    • Economy model with high thermal capacity
    • Precise temperatures with fast transitions from -60 to 200°C
    • No annual leak testing required per EU 517/2014 F-Gas Regulation
    • Effective testing and conditioning of electronic components, boards, and modules
    • Available for 50 and 60Hz operation
    • No need for Liquid Nitrogen (LN2) or Liquid Carbon Dioxide (LCO2)
    • Remote communications and set up and touch screen operation
    • User Defined Temperature Limits

     

     

    • Highly Damped Step Respond
    • Simple installation – No tuning require
    • Application-specific designs/products/
    • Capabilities to meet your needs
    • Ability to support massive machines, tools, systems

     

    • 6 degrees of freedom
    • Active gain starting from 0.5Hz
    • Variable Damping (patent pending)
    • Build In Artificial Intelligence Feature
    • Adjustable by software active bandwidth
    • Remote control
    • Built in real time diagnostic tools
      • Spectrum analyzer
      • Oscilloscope
    • Shaker Mode

     

    • 6 degrees of freedom
    • Active gain starting from 0.5Hz
    • Variable Damping (patent pending)
    • Build In Artificial Intelligence Feature
    • Adjustable by software active bandwidth
    • Remote control
    • Built in real time diagnostic tools
      • Spectrum analyzer
      • Oscilloscope
    • Shaker Mode

     

    • Highly Damped Step Respond
    • Simple installation – No tuning require
    • Application-specific designs/products/
    • Capabilities to meet your needs
    • Ability to support massive machines, tools, systems

     

    • Proven member of a modular Power Module family, more than 800 units are in service
    • Precision-regulated Bi-Polar output provides up to +12 to -12 Amps for Magnet loads.
    • Smooth operation through zero amps output current, no “Crossover” problems.
    • All 2510 MCOR12 Power Modules are identical and interchangeable.
    • Has two high-precision measurements of output current;
      • one is used to close the regulation control loop,
      • provides an independent monitoring signal to the Crate Interface Card.
    • Fault sensing circuitry in the module sets a Fault Latch which inhibits the output.
    • A (momentary) Sync input signal inhibits MOSFET switching when it is active (high);
      • this eliminate switching noise .
      • reduces power line noise during sensitive analog signal measurements.

     

    • Proven member of a modular Power Module family, more than 800 units are in service
    • Precision-regulated Bi-Polar output provides up to +30 to -30 Amps for Magnet loads.
    • Smooth operation through zero amps output current, no “Crossover” problems.
    • All 2510R30 MCOR30 Power Modules are identical and interchangeable
      • Programming Card is plugged into the replacement module.
    • Each channel has a critically-damped, LC noise filter with a cut-off frequency of about 8 kHz.
    • A 16-pin front panel diagnostics connector taps onto major circuit nodes which enables quick “inthe-crate” fault evaluation

     

    • 2U Chassis – 19″ rack mount 3.48” Height, 9.60” Depth and Weight 6lb.
    • Power 120V AC 60Hz
    • Washable front removable air filter
    • Ball Bearing AC fans provide 330 CFM
    • Dual plenum design
    • Cooling for 160mm,220mm depth modules
    • Diverts lower warmed air to rear of Cabinet
    • RM option diverts lower air to front of Cabinet

     

    • accommodate these control schemes
    • total control system interface on a single VME-standard card
    • occupies the left-most slot of the crate
    • monitoring voltage reference inputs, output voltages and fault conditions
    • standard VMEbus-compatible 6U by 220 mm board installed
    • Eurocard crate
    • Two 96-pin I/O connectors