1 800 665 7301 | info@tmetrix.com

    • 3GHz RF analog signal generator
    • AM, FM, PM, Sweep & Pulse Modulation
    • Exceptionally Low Phase Noise of -145dBc/Hz @100MHz and 10@kHz offset
    • Field ready, with 10” touch screen suited for day and night use and 2 hour battery operation
    • Remotely programmable via MATLAB, Python, LabVIEW and other software programming environments.
    • Removable uSD card for instrument security

     

    • Customizable & savable test setups
    • Program & Datalog Storage
    • User Defined Temperature Limits
    • Local & Remote Operations
    • LabView™ drivers
    • IEEE-488, RS232 ports

     

     

    • 20 Amp Operation: Full performance with 20 amp service
    • Automatic Power Reduction: Reduces power usage during idle periods
    • Heat Only Mode: Reduces power usage when cold temperatures are not used
    • WhisperStream Technology: quieter, smooth-sounding operation, 56 dBA
    • Frost Free Test Environment: dry air purge for tester interface, prevents condensation:
      0.5 to 3scfm (0.25 to 1.5 l/s)
    • Heated Defrost: quickly removes moisture buildup from internal chiller
    • DUT Temperature Control : Proprietary control algorithm enables DUT temperature to be directly controlled
    • Transition Rate*
      -55 to +125°C, approx. 10 seconds
      125 to -55°C, approx. 10 seconds
    • System Airflow Output*
      4 to 18scfm (1.9 to 8.5 l/s) Continuous
    • Temperature Range*
      -80 to +225°C (60Hz) No LN2 or LCO2 Required

     

    • High reliability thermal cycling without thermoelectric modules
    • Temperature range: -65 to 175°C
    • Cooling power:
      • 40W at -40°C for lower power devices
      • 55W at -55°C and 120W at -40°C.
    • Transition rate: up to <35 sec over 25 to -40°C
    • Easy and secure thermal connection to in-circuit or test socked DUT
    • Touch-screen controller: user-programmable temperatures, graphing, data logging
    • Communications options: Ethernet, USB, IEEE, RS232

     

  • -60° to +200°C

    • Economy model with high thermal capacity
    • Precise temperatures with fast transitions from -60 to 200°C
    • No annual leak testing required per EU 517/2014 F-Gas Regulation
    • Effective testing and conditioning of electronic components, boards, and modules
    • Available for 50 and 60Hz operation
    • No need for Liquid Nitrogen (LN2) or Liquid Carbon Dioxide (LCO2)
    • Remote communications and set up and touch screen operation
    • User Defined Temperature Limits

     

     

    • High voltage output to 300Vp-p (±150V)
    • Output current to 150 mA
    • Full power bandwidth from DC to >500kHz
    • Slew rate to 200V/µs
    • Low distortion
    • Low cost
    • Custom Configuration of gain and signal Ground

     

    • Single channel
    • High voltage output to 400Vp-p (±200V)
    • Output current to 125 mA
    • Full power bandwidth from DC to >500kHz
    • Slew rate to 400V/µs
    • Monitor Output
    • Precise signal amplification for multiple applications
    • Compatible with any of the Tabor waveform generators

     

    • High voltage output to 300Vp-p (±150V)
    • Output current to 100 mA per channel
    • Full power bandwidth from DC to >500kHz
    • Slew rate to 200V/µs
    • Low distortion
    • Low cost
    • Custom Configuration of: Gain, Signal Ground

     

    • 12GHz RF Analog Signal Generator
    • Extremely fast switching speed of <100μs
    • AM, FM, PM Sweep & Pulse Modulation
    • Extra small, compact module platform
    • Exceptionally Low Phase Noise of -145dBc/Hz @100MHz and 10@kHz offset
    • SPI and micro-USB integrated interfaces
    • Remotely programmable via MATLAB, Python, LabVIEW
    • and other software programming environments.
    • Flixible modular platform for OEM and custom requirements
    • and applications, to satisfy specific customer demands.
    • Multi instrument synchronization capability

     

    • 3 GHz RF Analog Signal Generator
    • Extremely fast switching speed of <100μs
    • AM, FM, PM Sweep & Pulse Modulation
    • Extra small, compact module platform
    • Exceptionally Low Phase Noise of -145dBc/Hz @100MHz and 10@kHz offset
    • SPI and micro-USB integrated interfaces
    • Remotely programmable via MATLAB, Python, LabVIEW
    • and other software programming environments.
    • Flixible modular platform for OEM and custom requirements
    • and applications, to satisfy specific customer demands.
    • Multi instrument synchronization capability

     

    • 6GHz RF Analog Signal Generator
    • Extremely fast switching speed of <100μs
    • AM, FM, PM Sweep & Pulse Modulation
    • Extra small, compact module platform
    • Exceptionally Low Phase Noise of -145dBc/Hz @100MHz and 10@kHz offset
    • SPI and micro-USB integrated interfaces
    • Remotely programmable via MATLAB, Python, LabVIEW
    • and other software programming environments.
    • Flixible modular platform for OEM and custom requirements
    • and applications, to satisfy specific customer demands.
    • Multi instrument synchronization capability

     

    • Proven member of a modular Power Module family, more than 800 units are in service
    • Precision-regulated Bi-Polar output provides up to +12 to -12 Amps for Magnet loads.
    • Smooth operation through zero amps output current, no “Crossover” problems.
    • All 2510 MCOR12 Power Modules are identical and interchangeable.
    • Has two high-precision measurements of output current;
      • one is used to close the regulation control loop,
      • provides an independent monitoring signal to the Crate Interface Card.
    • Fault sensing circuitry in the module sets a Fault Latch which inhibits the output.
    • A (momentary) Sync input signal inhibits MOSFET switching when it is active (high);
      • this eliminate switching noise .
      • reduces power line noise during sensitive analog signal measurements.

     

    • Proven member of a modular Power Module family, more than 800 units are in service
    • Precision-regulated Bi-Polar output provides up to +30 to -30 Amps for Magnet loads.
    • Smooth operation through zero amps output current, no “Crossover” problems.
    • All 2510R30 MCOR30 Power Modules are identical and interchangeable
      • Programming Card is plugged into the replacement module.
    • Each channel has a critically-damped, LC noise filter with a cut-off frequency of about 8 kHz.
    • A 16-pin front panel diagnostics connector taps onto major circuit nodes which enables quick “inthe-crate” fault evaluation

     

    • 2U Chassis – 19″ rack mount 3.48” Height, 9.60” Depth and Weight 6lb.
    • Power 120V AC 60Hz
    • Washable front removable air filter
    • Ball Bearing AC fans provide 330 CFM
    • Dual plenum design
    • Cooling for 160mm,220mm depth modules
    • Diverts lower warmed air to rear of Cabinet
    • RM option diverts lower air to front of Cabinet

     

    • accommodate these control schemes
    • total control system interface on a single VME-standard card
    • occupies the left-most slot of the crate
    • monitoring voltage reference inputs, output voltages and fault conditions
    • standard VMEbus-compatible 6U by 220 mm board installed
    • Eurocard crate
    • Two 96-pin I/O connectors

     

  • MCOR Modules

    MCOR 2/6/9/12

    Each module can be customized to provide maximum outputs of 2 amps, 6 amps, 9 amps, and 12 amps. Up to 16 of these can fit in a single 6U VME style crate.

    MCOR 30

    Each module can provide a maximum output 30 amps. Up to 8 of these can fit in a single 6U VME style crate.