1 800 665 7301 | info@tmetrix.com

    • High Bandwidth & Sampling Rate: Models available in 200 MHz, 350 MHz, 500 MHz, and 1 GHz with up to 5 GS/s sample rate.
    • Deep Memory Capture: Up to 250 Mpts in interleaved mode, allowing detailed waveform analysis.
    • Advanced Triggering & Waveform Capture: Zone Triggering, History Mode (100,000 waveforms), and a waveform capture rate of 500,000 wfm/s.
    • Math & Measurement Functions: 9 basic math functions (FFT, addition, subtraction, multiplication, division, etc.) and 50+ automatic measurement parameters.
    • Bode Plot & Power Analysis: Standard features include Bode Plot for frequency response testing and comprehensive power analysis for applications like power quality assessment, current harmonics, inrush current, and switching loss.
    • Mixed Signal Debugging: Optional 16-channel MSO capability for digital signal acquisition.
    • Connectivity & Remote Access: USB, LAN, and embedded web server for remote control and data analysis.

     

    • Available in 4.5-digit (60,000 count) and 6.5-digit (2,200,000 count) resolutions.
    • Wide measurement range:
      • DC Voltage: Up to 1000V
      • AC Voltage: Up to 750V (True RMS)
      • Current: 10A (AC/DC)
      • Resistance: 100MΩ (2-wire/4-wire)
      • Capacitance: 2nF – 100mF
      • Temperature measurements with TC and RTD sensor support.
    • High-speed measurements:
      • T3DMM4-5: 150 readings per second
      • T3DMM6-5: 10,000 readings per second
    • Advanced mathematical functions such as Max, Min, Standard Deviation, dBm/dB, Relative Measurement, Pass/Fail Analysis, and Histograms.
    • Connectivity: USB Device, USB Host, and LAN for remote operation via SCPI commands.
    • Data Storage: 1GB NAND flash memory for saving configuration files and test data.
    • Built-in cold junction compensation for accurate temperature measurements.
    • File management system supporting U-disc and local storage for convenient data access.
    • Comprehensive user interface with a dual-display system for easy navigation.
    • Automatic measurement functions, including statistical analysis, gating, and reference functions.

     

    • Proven member of a modular Power Module family, more than 800 units are in service
    • Precision-regulated Bi-Polar output provides up to +12 to -12 Amps for Magnet loads.
    • Smooth operation through zero amps output current, no “Crossover” problems.
    • All 2510 MCOR12 Power Modules are identical and interchangeable.
    • Has two high-precision measurements of output current;
      • one is used to close the regulation control loop,
      • provides an independent monitoring signal to the Crate Interface Card.
    • Fault sensing circuitry in the module sets a Fault Latch which inhibits the output.
    • A (momentary) Sync input signal inhibits MOSFET switching when it is active (high);
      • this eliminate switching noise .
      • reduces power line noise during sensitive analog signal measurements.

     

    • Proven member of a modular Power Module family, more than 800 units are in service
    • Precision-regulated Bi-Polar output provides up to +30 to -30 Amps for Magnet loads.
    • Smooth operation through zero amps output current, no “Crossover” problems.
    • All 2510R30 MCOR30 Power Modules are identical and interchangeable
      • Programming Card is plugged into the replacement module.
    • Each channel has a critically-damped, LC noise filter with a cut-off frequency of about 8 kHz.
    • A 16-pin front panel diagnostics connector taps onto major circuit nodes which enables quick “inthe-crate” fault evaluation

     

    • 2U Chassis – 19″ rack mount 3.48” Height, 9.60” Depth and Weight 6lb.
    • Power 120V AC 60Hz
    • Washable front removable air filter
    • Ball Bearing AC fans provide 330 CFM
    • Dual plenum design
    • Cooling for 160mm,220mm depth modules
    • Diverts lower warmed air to rear of Cabinet
    • RM option diverts lower air to front of Cabinet

     

    • accommodate these control schemes
    • total control system interface on a single VME-standard card
    • occupies the left-most slot of the crate
    • monitoring voltage reference inputs, output voltages and fault conditions
    • standard VMEbus-compatible 6U by 220 mm board installed
    • Eurocard crate
    • Two 96-pin I/O connectors

     

  • MCOR Modules

    MCOR 2/6/9/12

    Each module can be customized to provide maximum outputs of 2 amps, 6 amps, 9 amps, and 12 amps. Up to 16 of these can fit in a single 6U VME style crate.

    MCOR 30

    Each module can provide a maximum output 30 amps. Up to 8 of these can fit in a single 6U VME style crate.

    • provides precision bi-polar output currents
    • minimal zero-cross over distortion
    • 19” rack mounted 6U x 220 mm crate
    • crate has 17 slots; 16 (slot 0 thru 15)
    • connectors
      • J1 (ExtIntlk),
      • J2 (CrateOK),
      • J3 (Input Reference Voltages),
      • J4 (Output Monitors), and
      • J9 (Bitbus)