1 800 665 7301 | info@tmetrix.com

    • High-Density Testing – Up to 192 test positions per rack or 32 positions per desktop unit, ensuring high-throughput testing.
    • Independent Operation – Each test position operates independently, enabling simultaneous testing of multiple cells under different conditions.
    • User-Programmable Multi-Step Testing – Configure constant current, power, voltage, or resistance test sequences with easy-to-use software.
    • Precise Data Logging & Analysis – Logs current, voltage, time, temperature, and other critical parameters with high-speed data acquisition.
    • Real-Time Monitoring & Control – Data can be viewed, plotted, and analyzed in real-time, providing instant insights into cell performance.
    • Compact & Scalable Design – Available in desktop models (32 positions) and rack-mounted configurations (up to 192 positions per rack).
    • Seamless Integration – Powered by Maccor’s standard test system software, ensuring consistent performance and compatibility with existing systems.
    • Turn-Key Solution – Supplied as a complete system with PC and software, ensuring quick deployment and easy setup.
    • Advanced Safety Features – Includes automatic shutdown on power loss, reverse voltage protection, and internal circuit breakers for safe operation.
    • Versatile Applications – Suitable for single-cell testing, R&D, quality control, battery performance evaluation, and cycle life testing.

     

    • Advanced Formation Schedules – Supports up to 18 test steps with subroutines, allowing complex formation programs for Lithium-Ion and Lithium Polymer cells.
    • High Channel Density – Configurable with 512 to 2048 test channels, supporting large-scale production and pilot line testing.
    • Accurate Data Logging & Analysis – Logs Voltage, Current, Time, Capacity, Energy, and Cycle with high-speed data acquisition at 200 data points per second.
    • Flexible Test Modes – Supports Constant Current, Constant Voltage, Constant Power, and Constant Resistance operating modes.
    • Seamless Transition from Constant Current to Constant Voltage – Ensures smooth and accurate formation with no interruptions or spikes.
    • High Accuracy & Resolution –
      • Voltage Measurement Range: 0 to 5V
      • Voltage Accuracy: ±5 mV
      • Voltage Resolution: 16-bit
      • Current Resolution: 16-bit
    • Intelligent Cell Grading – Customizable grade profiles allow cell grading based on performance, ensuring consistent quality control.
    • High Scalability & Flexibility – Combine channels in parallel to increase current capability, supporting dynamic testing requirements.
    • Advanced Safety Features – Includes automatic shutdown on power failure, status recovery, and reverse voltage protection for safe operation.
    • Turn-Key Solution – Complete system with PC computer and software, ensuring quick deployment and easy setup.
    • Comprehensive Data Management – Automatic report generation, data backup, and processing with the MIMS Server Application.

     

    • Enterprise-class server.
    • Maximum system uptime
    • Designed to run 24×7, 365 days a year
    • M7© – Hosts up to 7 virtual machines representing 7 desktop computers
    • M22 © – Hosts up to 22 virtual machines representing 22 desktop computers
    • Server OS hosted on 2 Enterprise-grade SATA-SSD drives, RAID1
    • Virtual Machines hosted on shared array qty of eight (14TB) Enterprise-grade SAS-3 hard drives, RAID6
    • 2 Enterprise-grade PSU’s, 2 fans, 2 SATA Drives, 8 SAS-3 drives, all of which are hot-swappable CRU’s (customer replaceable units)

     

  • Efficient and Precise Cell Balancing

    The Maccor Cell Balancer is engineered to:

    • Independently charge and discharge each cell within a string, maintaining equal voltage levels across all cells.
    • Optimize battery pack performance by preventing cell overcharging or over-discharging, ensuring longer cycle life and enhanced safety.
    • Balance up to 8 cells per unit, with the ability to expand to larger battery packs by connecting multiple balancers in series.

    Seamless Integration with Maccor Test Systems

    The Maccor Cell Balancer is designed to integrate seamlessly with Maccor’s Mactest32.exe software, allowing users to:

    • Incorporate cell balancing steps directly into their test procedures.
    • Control and monitor cell balancing with real-time data visualization and automated data logging.
    • Customize balancing parameters, including charge and discharge currents, ensuring precision and flexibilityfor different battery chemistries and configurations.

     

    • Advanced Multi-Level Pulse (AMLP) – Design complex pulse profiles with up to 15,000 levels for high-precision battery testing.
    • Ultra-Fast Data Collection – Log data at 1 kHz across multiple channels with 20 kHz sampling for the first milliseconds, capturing critical transient events.
    • High-Resolution Step Length Control – Specify test steps as short as 750 microseconds with 1-microsecond increments, enabling ultra-fast dynamic testing.
    • High-Speed Set Point Lock-In – Achieve setpoint stabilization in as little as 1 millisecond, ensuring accurate and consistent results.
    • Customizable Waveforms – Stream external text test files with programmable waveforms, supporting constant current or power modes with 1-millisecond increments and 1-microsecond resolution.
    • Unmatched Flexibility – Run multiple unique waveforms in a single test without limitations on the number of levels.
    • Comprehensive Data Logging – Log data on current, voltage, time, and other factors continuously, providing comprehensive performance insights.
    • Optimized for Complex Testing – Ideal for cycle life testing, pulse power characterization, impedance measurements, and battery performance evaluation.
    • Scalable and Modular Design – Expand testing capabilities by integrating multiple Series 6000 units, ensuring scalable solutions for R&D and production environments.

     

  • HDO4000A oscilloscopes have 4 analog input channels, 12-bit resolution using Teledyne LeCroy’s HD4096 high-definition technology, up to 1 GHz of bandwidth and a compact form factor with a large 12.1” multi-touch display. They are ideal for debug and troubleshooting of power electronics designs, digital power management or power integrity analysis, automotive electronics systems, and deeply embedded or mechatronic designs.

     

  • The WaveSurfer 3000z has a 10.1″ capacitive touch display, the longest memory, and the deepest toolbox – all at an affordable price.

    • HD4096 technology provides 12-bit resolution all the time
    • 2ProBus input supports over 30 probes in 9 product categories
    • 3Long record capture of up to 25 Mpts
    • 412.1” 1280 x 800 HD capacitive touchscreen
    • 5Mixed-signal capability – debug complex embedded designs with integrated 16-channel mixed signal option
    • 6Easy connectivity with 2 USB 3.1 ports
    • 7MAUI with OneTouch user interface for intuitive and efficient operation

     

    • 15.6″ 1920 x 1080 capacitive touchscreen display
    • 24 analog input channels
    • 3ProBus input supports every Teledyne LeCroy probe
    • 4MAUI with OneTouch user interface for intuitive and efficient operation
    • 5Q-Scape multi-tab display architecture
    • 6Up to 250 Mpts of acquisition memory
    • 7HD4096 technology – 12 bits all the time
    • 8Buttons/indicators color-coded to associated waveform on display
    • 9Use cursors and adjust settings without opening a menu
    • 10Mixed Signal capability with 16 integrated digital channels
    • 116 USB 3.1 ports (2 front, 4 side)

     

    • HD4096 technology provides 12-bit resolution up to 8 GHz and 20 GS/s
    • Up to 5 Gpts of acquisition memory enables detailed viewing of long events
    • 15.6” 1900 x 1080 Full HD capacitive touchscreen
    • ProBus2 input supports up to 8 GHz bandwidth while maintaining support for legacy ProBus probes
    • MAUI with OneTouch user interface for intuitive and efficient operation
    • Waveform Control Knobs – Control channel, zoom, math and memory traces with the multiplexed vertical and horizontal knobs
    • Color-coded panel indicators – Trigger, horizontal and vertical indicator colors correspond to the associated waveform on the display
    • Cursor/Adjust Knobs – Enable and position cursors or adjust settings and parameters without opening a menu
    • Mixed Signal Capability – Debug complex embedded designs with integrated 16-channel mixed signal capability
    • Easy connectivity with seven USB 3.1 ports (3 front, 4 side) and UHD (4k) HDMI and DisplayPort outputs

     

    • Eye diagram (a), eye mask failure (b) and IsoBER eye opening analysis (c)
    • Jitter spectrum (a) with noise floor display (b) and inverse FFT of the periodic jitter (c)
    • Data dependent jitter (DDj) plot for each bit in synch with pattern (a) and with histogram (b)
    • Time interval error (TIE) jitter track analysis
    • Jitter histograms (a) with bathtub curves (b) and CDF plot (c)
    • Intersymbol interference (ISI) plots pinpoint bit sequences that have high ISI and are sources of bit errors
    • Jitter measurements table with full details for one or more “lanes” plus reference

     

    • 15.6” 1920 x 1080 capacitive touchscreen display
    • 8 analog input channels
    • ProBus input supports every Teledyne LeCroy probe
    • MAUI with OneTouch user interface for intuitive and efficient operation
    • Q-Scape multi-tab display architecture
    • Up to 5 Gpts of acquisition memory
    • HD4096 technology – 12 bits all the time
    • Buttons/indicators color-coded to associated waveform on display
    • Use cursors and adjust settings without opening a menu
    • Mixed Signal capability with 16 integrated digital channels
    • 6 USB 3.1 ports (2 front, 4 side)
    • HDMI and DisplayPort – supports 4K (4096 x 2304) external monitor
    • Removable SSD (standard)
    • View 16 channels on one display with OscilloSYNC
    • Reference Clock Input/Output for connecting to other equipment
    • USBTMC over USB 3.1 for fast data offload

     

    • S-parameters DC to 40 GHz, single-ended and mixed-mode
    • Impedance Profile with <1 mm resolution, differential and common-mode
    • Internal, automatic OSLT calibration
    • USB-connected, small, lightweight
    • Flexible display of the measurements
    • Remove effects from fixtures, connectors and cables
    • Emulate eye diagrams with CTLE, DFE and FFE equalization
    • Advanced jitter analysis

     

    • 4/8 analog channels + 1 external trigger
    • Analog channel bandwidth: up to 2 Ghz; real-time sampling rate of up to 10 GSa/s
    • Vertical resolution: 12-bits
    • Low noise floor: 153 μVrms at full bandwidth of 2 GHz
    • New generation of high speed display technology:
      • Waveform capture rates up to 170,000 wfm/s (normal mode), and 750,000 wfm/s (sequence mode)
      • Supports 256-level intensity grading and color temperature display modes
      • Memory depth up to 500 Mpts/channel
      • Digital trigger system
    • Intelligent trigger: Edge, Slope, Pulse, Window, Runt, Interval, Dropout, Pattern, Qualified, Nth edge, Setup/hold, Delay and Video (HDTV supported)
    • Serial bus triggering and decoder, supports protocols I2C, SPI, UART, CAN, LIN, CAN FD, FlexRay, I2S, MIL-STD-1553B, SENT and Manchester as standard
    • Segmented acquisition (Sequence) mode, dividing the maximum record length into multiple segments (up to 80,000), according to trigger conditions set by the user, with a very small dead time between segments to capture the qualifying event
    • History waveform record (History) function, the maximum recorded waveform length is 80,000 frames
    • Automatic measurements on 50+ parameters, supports statistics with histogram, track, trend, Gating measurement, and measurements on Math, History, Memory and Ref
    • 4 Math traces (8 Mpts FFT, addition, subtraction, multiplication, division, integration, differential, square root, etc.), supports formula editor

     

  • ✔ Available in 250 MHz & 350 MHz models
    ✔ 2, 4, and 8-channel options for multi-signal generation
    ✔ 16-bit vertical resolution for precise signal emulation
    ✔ Max sinewave frequency of 250 MHz & 350 MHz
    ✔ Wave Sequencing for complex test scenarios
    ✔ Mixed Signal Generation: Supports 8, 16, or 32 synchronized digital channels
    ✔ True Arbitrary Mode & Direct Digital Synthesis (DDS)
    ✔ Wideband output voltage window: ±24V (50Ω into High Impedance)
    ✔ Embedded noise simulation & jitter analysis
    ✔ Up to 1 Gpts of waveform memory per channel
    ✔ Seamless integration with LabVIEW™, MATLAB™, Python, and .NET

     

    • Channel Configurations: Available in 2, 4, and 8-channel models.
    • High Sampling Rate: Up to 12.32 GS/s in RF mode for high-frequency applications.
    • Superior Resolution: 16-bit vertical resolution for ultra-precise signal generation.
    • Waveform Memory: 4 Gpts per channel, ensuring long-duration complex waveform storage.
    • High Output Voltage: Up to 5 Vpp output voltage with ±2.5 V baseline offset (50 Ohm).