MEMORY HiLOGGER 8423

MEMORY HiLOGGER 8423

600-channel Data Logging System with 10ms Sampling

REQUEST A QUOTE



Description

Hioki Memory HiLoggers are high-speed data loggers for recording multiple chanels of voltage, temperature, resistance, humidity, rotation, and pulse signals, providing complete isolation within channel sets. The 8423 with optional input modules log data at 10ms speeds across up to 600 simultaneously, and is configurable and controllable using a PC. MEMORY HiLOGGER 8423

8423 main unit only

Note: 8423 cannot operate alone. You must install one or more optional input modules in the unit. Thermocouples are not provided by HIOKI, and must be purchased from a separate vendor.

CEUSB2LAN 

Key Features

• Capture data with 15 to a maximum of 600 channels

• Send data to the PC in real time

• Isolated to sustain up to 600 V between modules and earth

• USB 2.0, LAN 100BASE-TX, store to 1GB PC Card

• Simultaneous fast- and low-speed sampling allows for media storage space efficiency

■ Basic specifications (Accuracy guaranteed for 1 year, Post-adjustment accuracy guaranteed for 1 year)

 

No. of connectable units

 

Maximum 8 units (total 120 channels), Bundle 8 modules together to achieve a 120-channel system, Bundle 5 systems together to enable a maximum of 600 channels of simultaneous recording

 

Measurement parameters Model 8948

 

[No. of channels] 15 analog channels, isolated scanning method input (2 terminals: M3 screw type)
[Voltage measurement range] ±150 mV to ±100 V, 1-5V, Max. resolution 5 µV, Max. allowable input: 100 VDC, between channels: 200 VDC, to earth: 600 VAC/DC
[Temperature range] -200˚C to 2000˚C (depend on the sensor), thermocouples (K, J, E, T, N, R, S, B, W), Max. resolution 0.01˚C

 

Measurement parameters Model 8949

 

[No. of channels] 15 analog channels, isolated scanning method input (4 terminals: push-button type) (not isolated between channels at resistance temperature sensor & humidity sensor)
[Voltage measurement range] ±150 mV to ±60 V, 1-5V, Max. resolution 5 µV, Max. allowable input: 60 VDC, between channels: 120 VDC, to earth: 600 VAC/DC
[Temperature range] -200˚C to 2000˚C (depend on the sensor), thermocouples (K, J, E, T, N, R, S, B, W), Max. resolution 0.01˚C
[Resistance temperature sensor range] -200˚C to 800˚C, (Pt 100, JPt 100), Max. resolution 0.01˚C
[Humidity] 5.0 to 95.0% rh, (use with optional sensor), resolution 0.1% rh

 

Measurement parameters Model 8996

 

[No. of channels] 15 channels, digital/pulse input (2 terminals: M3 screw type, CH1-5, CH6-10, CH11-15 are common GND, No-voltage ‘a’ contact, open collector or voltage input)
[Totalized pulses] 0 to 1000M pulse, Max. resolution 1 pulse
[Rotation count] 0 to 5000/n (r/s), Resolution 1/n (r/s) *n = pulses per rotation (1 to 1,000)
[Digital input] Record ON/OFF digital signal per interval
[Max. allowable input] 50 VDC, between channels: 33 VACrms or 70 VDC, to earth: 600 VAC/DC, (Upper limit voltage that does not cause damage when applied between CH1-5, CH6-10, CH11-15 each channel and chassis, and between each UNITs)

 

Recording intervals

 

10 ms to 1 hr, 19 ranges (5s to 1hr when combined with humidity measurement), Dual sampling: Recording intervals can be specified for every input module (high-speed and low-speed)

 

Function

 

Measurement data are saved to the CF Card in real time, Trigger function, Digital filter (Input unit), Alarm output (use with the Alarm unit 8997), Data acquisition is controlled by the PC data acquisition program, FTP server function, HTTP server function

 

Interface

 

LAN: supports 100Base-TX, USB: Ver 2.0, mini-B receptacle, CF card slot

 

Power supply

 

Using the AC adapter 9418-15 (100 to 240 V, 50/60 Hz), 55 VA Max. (include AC adapter), 20 VA Max. (main unit only) (when connected with 8 units),
External DC Power: 9.6 V to 15.6 VDC, 20 VA Max. (when connected with 8 units) (Please contact HIOKI for connection cord)

 

Dimensions and mass

 

67 mm (2.64 in) W × 133 mm (5.24 in) H × 125 mm (4.92 in) D, 600 g (21.2 oz) (main unit 8423 only)

 

Accessories

 

Quick start manual × 1, Instruction manual × 1, AC adapter 9418-15 × 1, USB cable × 1, CD-R (data collection software “Logger Utility”) × 1, Connector cover × 1, Ferrite clamp × 1, Connection plate × 1

■ Combination status with LabVIEW or MATLAB script

Compatible models LabVIEW MATLAB script
8423 OK N/A
Get in touch with us to inquire about our tailored consulting services.