1 800 665 7301 | info@tmetrix.com

Power Supplies and Power Test

Showing 1–16 of 23 results


  • Multi-Range DC Power Supply Triple Outputs, 3 x 35V/3A 315W, No Interfaces

    • Three or four independent and full performance outputs
    • Simultaneous display of meters and settings for all outputs
    • Instant access to voltage/current setting for any output
    • Multiple ranges on each output for wider voltage/current choice
    • Instant individual on/off control plus sequencable multi on/of
    • Up to 250 settings memories for individual or multiple outputs

     

  •  

    • Reliable and Repeatable solid state signal generation
    • Standard Internal/external pulse modulation
    • USB/Ethernet Control
    • 10 MHz external or internal reference
    • 100 Hz Frequency Resolution
    • Easily portable
    • Sized to fit into a single rack unit for ATE applications

     

  • with analogue and digital control, USB, RS232, LAN (LXI) and GPIB

    • Versatile solution for direct testing of dc power sources and PFCs
    • Constant current, resistance, conductance and power modes
    • Wide voltage and current range, 10 to 500V and 0 to 16A
    • 400 watts continuous dissipation at 28°C (360W at 40°C)
    • High resolution and accuracy for level setting
    • Built-in transient generator with variable slew
    • Current monitor output for waveform viewing
    • Variable drop-out voltage for battery testing
    • High resolution backlit graphic LCD with soft key control
    • Analogue remote control of levels and TTL control of on/off and transient switching
    • Front and rear input terminals
    • Load inputs rated to CAT II (300V)
    • Full bus control via USB, RS232, GPIB and LXI compliant LAN interfaces

     

  • with analogue and digital control, USB, RS232, LAN (LXI) and GPIB

    • Versatile solution for direct testing of dc power sources and PFCs
    • Constant current, resistance, conductance and power modes
    • Wide voltage and current range, 10 to 500V and 0 to 16A
    • 400 watts continuous dissipation at 28°C (360W at 40°C)
    • High resolution and accuracy for level setting
    • Built-in transient generator with variable slew
    • Current monitor output for waveform viewing
    • Variable drop-out voltage for battery testing
    • High resolution backlit graphic LCD with soft key control
    • Analogue remote control of levels and TTL control of on/off and transient switching
    • Front and rear input terminals
    • Load inputs rated to CAT II (300V)
    • Full bus control via USB, RS232, GPIB and LXI compliant LAN interfaces

     

    • Multiple ranges on each output for wider voltage/current choice
    • Four independent 105W full performance outputs
    • Instant individual on/off control plus sequencable multi on/off
    • Simultaneous display of meters and settings for all outputs
    • Up to 250 settings memories for individual or multiple outputs
    • Instant access to voltage/current setting for any output
    • USB, RS-232, LXI compliant LAN, and GPIB* interfaces (P versions)
    • USB, RS-232, LXI compliant LAN, and GPIB* interfaces (P versions)
      Duplicate power and sense terminals at rear (P versions)

     

    • compact and completely modular design
    • high effectiveness in all operation modes, few requirements on building infrastructure
    • ability to use an existing liquid cooling system directly
    • optional matched liquid-to-air cooling unit TC.LAE available
    • possibility of upgrading to systems of up to 1 MVA
    • high level of system dynamics, ≤ 5 kHz modulation bandwidth
    • non-restrictive capability of refeeding in the Q4 operation mode
    • possibility of operating as an autonomous 4-Q and 3-phase quasi-analogue amplifier
    • possibility of “Hardware-in-the loop”-operation (HIL mode)
    • user friendly application software with pre-configured test patterns
    • possibility of integrating into a complete SAS simulation and test system
    • galvanic isolation available as an option without derating the simulator port data

     

  • Bidirectional (source & sink), Regenerative 0…65VDC to 0…1500VDC, 20kW up to 1.5 MW 

    • cell system nominal voltage and type of chemistry
    • number of cells
    • internal resistance and associated parameters
    • cell temperature progression
    • allowed current
    • charge efficiency
    • energy computing and management facilities
    • time-dependent and functional dependent parameters

     

    • Setting of operational parameters for each output phase: (frequency, phase, voltage, basic waveform)
    • Defining functional blocks enabling a wide variety of modulation capabilities
    • Defining, editing and storing of even complex and long test sequences
    • Preview window for output voltage waveforms
    • LC load mode, definition of complex equivalent circuits
    • Hand drawing curve tool and FOURIER tool (harmonics synthesis)
    • TC.ACS provides an extensive safety concept in order to detect unwanted or off-limit conditions very quickly and to initiate controlled limiting or even a shutdown.

     

    • compact and completely modular design
    • high effectiveness in all operation modes, few requirements on building infrastructure
    • ability to use an existing liquid cooling system directly
    • optional matched liquid-to-air cooling unit TC.LAE available
    • possibility of upgrading to systems of up to 1 MVA
    • high level of system dynamics, ≤ 5 kHz modulation bandwidth
    • non-restrictive capability of refeeding in the Q4 operation mode
    • possibility of operating as an autonomous 4-Q and 3-phase quasi-analogue amplifier
    • possibility of “Hardware-in-the loop”-operation (HIL mode)
    • user friendly application software with pre-configured test patterns
    • possibility of integrating into a complete SAS simulation and test system
    • galvanic isolation available as an option without derating the simulator port data

     

  • Photovoltaic applications, the quality and technical data of the AC-DC converter is of primary interest. Solar installations are intended for a lifetime of roughly 20 years, therefore even fractions of a percent in efficiency will represent significant amounts of energy losses.

  • Programmable Grid-tie Sink High-Power DC Supply,

  • Programmable Grid-tie Source & Sink Technology
    Wide range of power 20 to 512 kW, expandable up to several MW
    DC output voltages from 0-65 VDC up to 0-1500 VDC, +/- 40 A up to +/- 600 A

  • 20 MHz to 6 GHz Programmable Signal Generators

    • USB powered and controlled
    • Includes easy-to-install-and-use GUI
    • Programmable frequency stepping
    • Operate multiple devices directly from a PC or self-powered USB hub
    • Autonomous operation from USB hub or battery pack
    • Easily programmable for ATE applications
    • Robust aluminum construction
    • Customization available for unique requirements
    • API DLL and LabVIEW compatible drivers available
    pdf

    Download Data Sheeet

     

  • Bench/System DC Power Supplies, PowerFlex or PowerFlex+ regulated Single or Dual Outputs 1200 watts, with/without Digital Remote Interfaces
    • Single or dual outputs, 1200 watts total
    • PowerFlex design gives variable voltage/current combinations within a power envelope
    • Up to 60 volts or 80 volts and up to 50 amps
    • Setting by direct numeric entry or by spin wheel
    • High setting resolution of 1mV in up to 60 volts
    • Low noise of < 3mV rms at full power
    • Bench or rack mounting, front and rear terminals
    • Quasi analogue remote control
    • RS232, USB GPIB & LAN interfaces (P models)

     

  • Bench/System DC Power Supply, PowerFlex Regulation, Smart Analog Controls Single or Dual Outputs, 360 to 840 watts, with/without Remote Interfaces
    • PowerFlex design gives variable voltage and current combinations within a maximum power range
    • Up to 60 volts and up to 20 amps
    • 180 watts or 420 watts maximum per output
    • Isolated outputs can be wired in series or parallel
    • Constant voltage or constant current operation
    • Settings Locking (S-Lock)
    • PowerFlex or fixed-range operation
    • Variable OVP trips
    • Selectable remote sense terminals
    • Compact quarter or half rack 3U case size
    • Isolated analogue remote control (CPX400SA only)
    • RS232, USB, GPIB & LXI compliant LAN (P models only)

     

  • Bench/System DC Power Supply, Multi-Range, Digital Control Triple Outputs, 315 or 378W with/without Remote Interfaces
    • Three high performance outputs each with full functionality
    • Range switching gives variable voltage/current combinations
    • Shared power mode provides double power from a single output
    • Low output noise and ripple via linear final regulation
    • High setting resolution of up to 1mV and 0.1mA
    • Variable OVP and OCP trips on all outputs
    • 50 setting memories per output plus 50 linked memories
    • Selectable voltage tracking (isolated tracking)
    • Selectable current meter averaging
    • Switchable remote sense capability
    • Graphic LCD provides simultaneous output metering
    • Numeric or spin-wheel control of all parameters
    • Individual or combined output on/off control with
    • programmable delay sequencing.
    • 3U half-rack case for bench or rack mounting
    • GPIB, RS-232, USB and LAN (LXI) interfaces (-P models)
    • Duplicate power & sense terminals at rear (-P models)

    MX100T and MX100TP:

    • 315 watts total power
    • Three outputs of equal power, each capable of 35V at 3A
    • Range switching provides up to 70 volts and up to 6 amps

    MX180T and MX180TP:

    • 375 watts plus of total power
    • Two high power outputs plus one low power output
    • High power outputs each capable of 30 volts at 6 amps
    • Range switching provides up to 120 volts or up to 20 amps
    • Low power output provides up to 12 volts or up to 3 amps

     


Showing 1–16 of 23 results