Uncategorized

Showing 49–64 of 176 results


    • High Power Density 3.3kW in 2U
    • Wide Range of popular worldwide AC inputs, 1ø (230VAC) & 3ø (208VAC, 400VAC)
    • Active Power Factor Correction (Single-Phase & Three-Phase AC Input)
    • Output Voltage up to 600V, Current up to 400A
    • Built-in RS-232/RS-485 Interface Standard
    • Global Commands for Serial RS-232/RS-485 Interface
    • Auto-Re-Start / Safe-Start: user selectable
    • Last-Setting Memory
    • High Resolution 16 bit ADCs & DACs
    • Low Ripple & Noise
    • Front Panel Lock selectable from Front Panel or Software
    • Reliable Encoders for Voltage and Current Adjustment
    • Constant Voltage/Constant Current auto-crossover
    • Parallel Operation with Active Current Sharing; up to four identical units.
    • Advanced Parallel Master / Slave. Total Current is Programmed and Measured via the Master.
    • Independent Remote ON/OFF and Remote Enable/Disable

     

     

    • High Power Density 750W in 1U full-rack size
    • Wide Range Input (85 – 265Vac Continuous)
    • Active Power Factor Correction (0.99 typical)
    • Output Voltage up to 600V, Current up to 100A
    • Built-in RS-232/RS-485 Interface Standard
    • Last Setting Memory; Front Panel Lockout
    • Advanced Parallel reports total current up to four identical units

     

    • Wide Range Input (85 – 265Vac Continuous)
    • Active Power Factor Correction (0.99 typical)
    • Output Voltage up to 600V, Current up to 100A
    • Built-in RS-232/RS-485 Interface Standard
    • Last Setting Memory; Front Panel Lockout
    • Advanced Parallel reports total current up to four identical units

     

    • Integrated acceleration (velocity) signal
    • Self-contained seismic velocity transmitter
    • Signal integrator
    • Piezo-electric accelerometer
    • RMS peak detector
    • 4-20 mA signal conditioner

     

  • ST5484E Seismic Velocity Transmitter with high- and low-pass filter options

    Supply Voltage Inputs 11 – 29.6 VDC (24 VDC nominal) (intrinsically safe), 11 – 30 VDC (24 VDC nominal) (explosion proof and non-incendive)

    Type: 24″ Flying Leads – 2-wire

     

     

    • Dual inputs allows Differential or Phaseto-Phase voltage measurement
    • High speed DSP provides up to 60 filtered readings per second
    • True RMS AC measurement from 0.01Hz to 600Hz—covering VLF to aviation frequencies
    • AC noise rejection 78dB—for rock solid, six digit DC Measurements
    • Optional battery pack goes up to 11 hours between charges
    • G Series—high input impedance probes for electrostatic applications
    • CE mark Certified to EN61010
    • Available ISO 17025 accredited calibration
    • Three year extended warranty (one year standard warranty)

     

    • The S type Channel card provides economical, high-performance power measurement with a basic 0.1% accuracy and enough bandwidth to handle waveforms up to 1.25 MHz.
    • The A-type ultra-precision Channel card offers a 2-year accuracy rating of 0.03% of reading and bandwidth up to 1.25 MHz.
    • The W type Wideband Channel card performs precision power measurements on the toughest real-world waveforms, with sampling speed fast enough to tame waveforms up to 5Mhz

     

    • The S type Channel card provides economical, high-performance power measurement with a basic 0.1% accuracy and enough bandwidth to handle waveforms up to 1.25 MHz.
    • The A-type ultra-precision Channel card offers a 2-year accuracy rating of 0.03% of reading and bandwidth up to 1.25 MHz.
    • The W type Wideband Channel card performs precision power measurements on the toughest real-world waveforms, with sampling speed fast enough to tame waveforms up to 5Mhz

     

    • The S type Channel card provides economical, high-performance power measurement with a basic 0.1% accuracy and enough bandwidth to handle waveforms up to 1.25 MHz.
    • The A-type ultra-precision Channel card offers a 2-year accuracy rating of 0.03% of reading and bandwidth up to 1.25 MHz.
    • The W type Wideband Channel card performs precision power measurements on the toughest real-world waveforms, with sampling speed fast enough to tame waveforms up to 5Mhz

     

  • • High Power Accuracy of 0.045% For All Channels
    • Improved Voltage and Current Self-Heating Adders
    • Faster Sampling Rates & Bandwidth Performance
    • Greater Harmonic Frequencies

     

  • • Ultra High Power Accuracy of 0.024% For All Channels
    • Improved Voltage and Current Self-Heating Adders
    • Faster Sampling Rates & Bandwidth Performance
    • Greater Harmonic Frequencies

     

    • 3″ Color Touch Display – Easy To Use Intuitive User Interface
    • 6 Functions Choose From – AC/DC Hipot, IR, Ground Bond, Continuity & Built-in Switching
    • Made in the USA – Designed & Built in San Diego CA
    • Compact, Lightweight, Rugged, Fan Free, Fast (100mS min test time) & Accurate
    • 5KV AC/DC Hipot, 20mA max source current
    • Ground Bond 1-30A RMS (42 A peak), 100µΩ Resolution
    • 100 nano-Amp Leakage Current Resolution
    • Low Cost of Ownership – 2 Year Calibration Interval

     

  • AC Power Cords 14AWG PLUG-SJ 9FT (2.7m) BLACK

     

    • PowerFlex design gives variable voltage and current combinations within a maximum power envelope
    • Up to 60V and up to 20A per output (420W maximum)
    • Constant voltage or constant current operation
    • Low output noise and good transient response
    • PowerFlex or fixed-range operation plus custom limits
    • True analogue controls with digital settings locking
    • Independent outputs or isolated voltage tracking (dual)
    • Outputs can be wired in series or parallel for 120V or 40A
    • Variable OVP trips; safety binding-post terminals
    • 4 digit fixed resolution meters; selectable remote sensing
    • Compact ½ rack 3U case (dual) or ¼ rack 3U case (single)
    • Duplicate terminals at rear on CPX400SA, SP & DP
    • Isolated analogue control interface (CPX400SA only)
    • GPIB, RS-232, USB and LAN interfaces with LXI compliance (CPX400SP & CPX400DP only)

     

  • RATED POWER OUTPUT  30W minimum
    POWER OUTPUT  @ 3dB COMPRESSION Nominal, 35W; Minimum, 25W
    POWER OUTPUT @ 1dB COMPRESSION Nominal, 30W; Minimum, 20W
    SMALL SIGNAL GAIN FLATNESS  ±1.0 dB typical; ±2.0 dB maximum
    FREQUENCY RESPONSE  0.7–6 GHz instantaneously
    GAIN  45 dB minimum
    NOISE FIGURE  8.5 dB typical

    download

    • 2U Chassis – 19″ rack mount 3.48” Height, 9.60” Depth and Weight 6lb.
    • Power 120V AC 60Hz
    • Washable front removable air filter
    • Ball Bearing AC fans provide 330 CFM
    • Dual plenum design
    • Cooling for 160mm,220mm depth modules
    • Diverts lower warmed air to rear of Cabinet
    • RM option diverts lower air to front of Cabinet

     


Showing 49–64 of 176 results

Filters

 

Suppliers

Latest News