  • Single-phase, 2U, industrial amplifier/battery simulator

    • Bench-sized
    • Powered from 120V/230VAC
    • Source and Sink (4 quadrant)
    • Rugged Design
    • 3-Year, No-Fault Warranty

    Key Performance Capabilities:

    • Drop outs and surges as fast as 1.2µs
    • Small signal response up to 1 MHz
    • 13.5 VDC at up to 28A
    • Field-selectable ±40V, 75V or 150V potential

     

  • The First Wide-Bandwidth, High-Power Digital Amplifiers

    • Max Continuous Output Current: 300A RMS
    • Surge Rating: 2X power at up to 400 VP or 750A
    • Apparent Power Rating: Up to 5X continuous power rating atup to 400 VP or 750A
    • Supply Voltage: Three-phase, 208V ±10%, 60A, 50/60 Hz; 400V ±10%, 15A version available.
    • Dimensions (HxWxD): 36.5 x 21.0 x 30.75 inches (92.7 x 53.3 x 78.1 cm)
    • Weight: Appx. 540 lbs. (244.9 kg)

     

    • 20 Amp Operation: Full performance with 20 amp service
    • Automatic Power Reduction: Reduces power usage during idle periods
    • Heat Only Mode: Reduces power usage when cold temperatures are not used
    • WhisperStream Technology: quieter, smooth-sounding operation, 56 dBA
    • Frost Free Test Environment: dry air purge for tester interface, prevents condensation:
      0.5 to 3scfm (0.25 to 1.5 l/s)
    • Heated Defrost: quickly removes moisture buildup from internal chiller
    • DUT Temperature Control : Proprietary control algorithm enables DUT temperature to be directly controlled
    • Transition Rate*
      -55 to +125°C, approx. 10 seconds
      125 to -55°C, approx. 10 seconds
    • System Airflow Output*
      4 to 18scfm (1.9 to 8.5 l/s) Continuous
    • Temperature Range*
      -80 to +225°C (60Hz) No LN2 or LCO2 Required

     

    • High reliability thermal cycling without thermoelectric modules
    • Temperature range: -65 to 175°C
    • Cooling power:
      • 40W at -40°C for lower power devices
      • 55W at -55°C and 120W at -40°C.
    • Transition rate: up to <35 sec over 25 to -40°C
    • Easy and secure thermal connection to in-circuit or test socked DUT
    • Touch-screen controller: user-programmable temperatures, graphing, data logging
    • Communications options: Ethernet, USB, IEEE, RS232

     

  • -60° to +200°C

    • Economy model with high thermal capacity
    • Precise temperatures with fast transitions from -60 to 200°C
    • No annual leak testing required per EU 517/2014 F-Gas Regulation
    • Effective testing and conditioning of electronic components, boards, and modules
    • Available for 50 and 60Hz operation
    • No need for Liquid Nitrogen (LN2) or Liquid Carbon Dioxide (LCO2)
    • Remote communications and set up and touch screen operation
    • User Defined Temperature Limits

     

     

  • Key Performance Capabilities:

    • Slew rates up to 60 V/µsec.
    • Up to 240A DC at +50VDC or –50VDC (4301-240 configuration).
    • Can provide pulses of up to 800 amps at voltages of up to ±100V (4301-240 configuration).
    • Adjustable compensation allows the system to maintain a 50V/2 µsec rise-time over a wide range of current outputs.

     

  • Key Performance Capabilities:

    • Bandwidth: DC to 50 kHz
    • Voltage: 0 to 250 VRMS; 0 to 350 VDC
    • Current: 100 to 500 ARMS
    • Distortion: 0.1%
    • Power: 4 kW to 20 kW*Power levels up to 5X rated power when driving reactive loads
    • High power efficiency and density

    *Models available with output from 4 kW to 20 kW (capable of up to 125 kVA).

     

  • Key Performance Capabilities:

    • 4-Quadrant – Can source and sink current
    • ±80V – DC supply for 12V to 48V systems; meets 80V surge requirements
    • 300 kHz Sine – DC ripple tests for all major standards
    • 3µs Rise Time – Exceeds surge and dropout slew rate requirements
    • 3mΩ DC Source Impedance – Out-performs ISO 7637-2 requirements
    • Supports ground reference and supply offset testing required for ISO 16750-2 Sect. 4.8 and other similar standards

     

  • Key Performance Capabilities:

    • Up to 900 watts RMS power output (7136 model)
    • Small signal response up to 400 kHz
    • User-adjustable precision DC offset
    • User-adjustable current limit: 1A to 25A
    • 4-quadrant operation
    • AC/DC coupled

     

  • Phase -Models Kitted for installation into End User’s Cabinet  and Phase -Models including Cabinet and Emergency Power off  (EPO)1

     

  • AC, DC, AC+DC, Single and Three – Phase -Models Including Cabinets

    Rated Power 60,000 (vA),  Output Power 21,000(w)  Output form  1,2,3Ø, Output Volt-Max 300(L-N)/425 (VAC/VDC)(1), Output AMPS/PHS 166.7 / 83.3 (AAC/ADC)(2), Input Power Form (3) 3 Ø, Panel Height (4) 27 (U) and Weight 527/240 (LBS./KG).

     

  • AC, DC, AC+DC, Single and Three – Phase -Models Including Cabinets

    Rated Power 30,000 (vA),  Output Power 21,000(w)  Output form  1,2,3Ø, Output Volt-Max 300(L-N)/425 (VAC/VDC)(1), Output AMPS/PHS 125.0 / 62.5  (AAC/ADC)(2), Input Power Form (3) 3 Ø, Panel Height (4) 27 (U) and Weight 466/212 (LBS./KG).

     

  • AC, DC, AC+DC, Single and Three – Phase -Models Including Cabinets

    Rated Power 30,000 (vA),  Output Power 21,000(w)  Output form  1,2,3Ø, Output Volt-Max 300(L-N)/425 (VAC/VDC)(1), Output AMPS/PHS 25.0/13.9 (AAC/ADC)(2), Input Power Form (3) 3 Ø, Panel Height (4) 15 (U) and Weight 320/146(LBS./KG).

     

  • AC, DC, AC+DC, Single and Three – Phase -Models without Cabinets

    Rated Power 15000 (vA),  Outputform  1,2,3Ø, Output Volt-Max 300(L-N)/425 (VAC/VDC)(1), Output AMPS/PHS 41.7 / 21.0 (AAC/ADC)(2), Input Power Form (3) 3 Ø, Panel Height (4) 4 (U) and Weight 112/51 (LBS./KG).

     

  • AC, DC, AC+DC, Single and Three – Phase -Models without Cabinets

    Rated Power 15000 (vA),  Outputform  1,2,3Ø, Output Volt-Max 300(L-N)/425 (VAC/VDC)(1), Output AMPS/PHS 41.7 / 21.0 (AAC/ADC)(2), Input Power Form (3) 3 Ø, Panel Height (4) 4 (U) and Weight 112/51 (LBS./KG).

     

  • AC, DC, AC+DC, Single and Three – Phase -Models without Cabinets

    Rated Power  12000 (vA),  Outputform  1,2,3Ø, Output Volt-Max 300(L-N)/425 (VAC/VDC)(1), Output AMPS/PHS  33.3/16.7 (AAC/ADC)(2), Input Power Form (3) 3 Ø, Panel Height (4) 4 (U) and Weight 112/51 (LBS./KG).

     