  • Multi-Range DC Power Supply with digital control, 3 or 4 Outputs, 315 to 420W with/without Remote Interfaces

    • hree or four high performance outputs each with full functionality
    • Range switching gives variable voltage/current combinations
    • Shared power mode provides double power from a single output
    • Low output noise and ripple via linear final regulation
    • High setting resolution of up to 1mV and 0.1mA
    • Variable OVP and OCP trips on all outputs
    • 50 setting memories per output plus 50 linked memories
    • Selectable voltage tracking (isolated tracking)
    • Selectable current meter averaging
    • Switchable remote sense capability
    • Graphic LCD provides simultaneous output metering
    • Numeric or spin-wheel control of all parameters
    • Individual or combined output on/off control with programmable delay sequencing.
    • 3U half-rack case for bench or rack mounting (4U rack kit accessory available)
    • RS-232, USB and LAN (LXI) interfaces (P models), GPIB option
    • Duplicate power & sense terminals at rear (P models)

     

  • with 10MHz to 3.6 or 6.0GHz bandwidth options

    True hand-held battery powered RF spectrum analyzers.

    • 10MHz to 3600MHz or 6000MHz frequency range
    • Resolution bandwidths from 300Hz to 10MHz (1:3:10)
    • -120dBm typical noise floor at -40dBm ref. level/10kHz RBW
    • Measurement in dBm or dBµV, mV or µW
    • Zero span mode with AM and FM audio demodulation
    • Trace modes of normal, peak hold and trace average
    • Live, View and Reference traces in contrasting colours
    • Twin markers with readout of absolute & difference values
    • Smart marker movement with selectable peak tracking
    • Frequency counter with down to 10Hz resolution
    • Frequency presets and independent state storage
    • Auto-find automatically sets sweep parameters for the highest signal found
    • Unlimited storage for waveforms, set-ups and screens
    • User assignable file names, file stamping from real-time clock
    • USB interfaces for Flash drives and PC connection
    • Comprehensive status and context sensitive help screens
    • Rechargeable lithium ion battery giving more than 3 hours continuous operation from a charge
    • Smaller and lighter than other spectrum analyzers (weight only 0.56 kg)

     

  • DC Power Supply single output, 80V/50A 750W PowerFlex+, LAN & USB interfaces, GPIB Option

    • Wide range of voltage/current combinations
    • Up to 80V and up to 50A within the same power envelope
    • Low output ripple and noise of <3mV rms at full power
    • High setting resolution of 1mV
    • Analogue control interfaces for voltage and current
    • Bench or rack mounting, front and rear terminals
    • LAN (LXI), USB, GPIB interfaces (GPIB optional on QPX750SP)

     

    • 150kHz to 3GHz (TGR2053) and 150kHz to 1.5GHz (TGR2051) frequency range
    • High signal purity, phase noise <-117dBc/Hz (typical) at 1GHz output and 10kHz offset
    • Amplitude range of -127dBm to +13dBm
    • 0.1dBm amplitude setting resolution
    • Internal or external analogue modulations (AM, FM, PM)
    • Amplitude can be set in dBm, dBμV or in linear Volts.
    • Internal or external digital modulations – ASK, OOK, FSK, 3FSK, 4FSK, GFSK, MSK, GMSK, HMSK & PSK with U01 option
    • Modulation Synchronisation
    • Fast amplitude and/or frequency sweeps with comprehensive triggering
    • 5ms sweep settling time
    • 1ppm frequency accuracy, <1ppm drift in first year
    • Modulation waveform output on the rear panel
    • Internal waveforms include: Sine, Square, Ramp, Triangle, PRBS (various lengths) and user-defined pattern
    • Simple operation with the colour touch screen
    • Programmable via USB, LAN (LXI) and GPIB (optional), SCPI compatible
    • Compatible with previous Aim-TTi RF generators

     

  • The EME Guard Plus is a lightweight and robust personal protection monitor designed to ensure the safety of workers operating near electromagnetic field (EMF) emitters such as antennas, radars, and base stations. With a frequency range of 1 MHz to 40 GHz, this device continuously monitors and records EMF exposure levels while providing immediate audio, visual, and vibrating alerts when exposure exceeds predefined safety thresholds. Customizable alarm settings and a triaxial isotropic probe ensure accurate and reliable measurements.

     

  • The EME Guard XS Radar is a state-of-the-art RF safety monitor, specifically designed for workers operating near radar transmitters and antennas. With its isotropic tri-axis E-field sensors, this compact device provides continuous EMF monitoring over a frequency range of 1 MHz to 40 GHz, including short pulsed signal detection. Equipped with audio and visual alarms, it alerts users instantly when EMF exposure exceeds predefined safety thresholds, creating a safer working environment for military, aviation, and telecom personnel.

     

    • 20 Amp Operation: Full performance with 20 amp service
    • Automatic Power Reduction: Reduces power usage during idle periods
    • Heat Only Mode: Reduces power usage when cold temperatures are not used
    • WhisperStream Technology: quieter, smooth-sounding operation, 56 dBA
    • Frost Free Test Environment: dry air purge for tester interface, prevents condensation:
      0.5 to 3scfm (0.25 to 1.5 l/s)
    • Heated Defrost: quickly removes moisture buildup from internal chiller
    • DUT Temperature Control : Proprietary control algorithm enables DUT temperature to be directly controlled
    • Transition Rate*
      -55 to +125°C, approx. 10 seconds
      125 to -55°C, approx. 10 seconds
    • System Airflow Output*
      4 to 18scfm (1.9 to 8.5 l/s) Continuous
    • Temperature Range*
      -80 to +225°C (60Hz) No LN2 or LCO2 Required

     

    • High reliability thermal cycling without thermoelectric modules
    • Temperature range: -65 to 175°C
    • Cooling power:
      • 40W at -40°C for lower power devices
      • 55W at -55°C and 120W at -40°C.
    • Transition rate: up to <35 sec over 25 to -40°C
    • Easy and secure thermal connection to in-circuit or test socked DUT
    • Touch-screen controller: user-programmable temperatures, graphing, data logging
    • Communications options: Ethernet, USB, IEEE, RS232

     

  • -60° to +200°C

    • Economy model with high thermal capacity
    • Precise temperatures with fast transitions from -60 to 200°C
    • No annual leak testing required per EU 517/2014 F-Gas Regulation
    • Effective testing and conditioning of electronic components, boards, and modules
    • Available for 50 and 60Hz operation
    • No need for Liquid Nitrogen (LN2) or Liquid Carbon Dioxide (LCO2)
    • Remote communications and set up and touch screen operation
    • User Defined Temperature Limits

     

     

  • 1.5GHz & 3GHz

    • 1.5GHz and 3GHz models
    • Internal DDS baseband generator provided as logic LF output
    • Compatible with previous Aim-TTi RF generators
    • Phase noise <-117dBc/Hz (typ.) at 1GHz output 10kHz offset
    • Extensive analog and digital modulations
    • Amplitude range of -127dBm to +13dBm
    • High signal purity
    • Fast amplitude and/or frequency sweeps

     

  • Dual Measurement Bench Multimeter with USB and optional RS232, LXI/LAN and GPIB interfaces

    1908 Digit Multimeter Series

     

    • Affordable 5.5 digit high performance bench/portable multimeter
    • Dual display and dual measurement capability
    • Mains power or Internal rechargeable batteries for true portability
    • High accuracy and resolution: 0.02%, 1µV, 0.1µA, 1mΩ
    • True RMS AC, Frequency, capacitance and temperature measurements
    • Wide range of computing functions e.g. Ax + B
    • USB interface standard, RS232, LAN/LXI and GPIB optional

     

    • Affordable 5.5 digit high performance bench/portable multimeter
    • Dual display and dual measurement capability
    • Mains power or Internal rechargeable batteries for true portability
    • High accuracy and resolution: 0.02%, 1µV, 0.1µA, 1mΩ
    • True RMS AC, Frequency, capacitance and temperature measurements
    • Wide range of computing functions e.g. Ax + B
    • USB interface standard, RS232, LAN/LXI and GPIB optional

     

    • Frequency up to 160MHz, 15 digits or 1µHz resolution
    • Wideband noise generator | high resolution pulse generator
    • Arbitrary waveforms up to 16bits at 800MS/s
    • Comprehensive internal/external digital and analog modulations
    • Two identical channels with phase control, coupling and tracking
    • USB and LXI compliant LAN interfaces, plus optional GPIB interface

     

  • Pulse and Universal Generator with 25 or 50MHz models, single or dual channel

    TGP3100 Series

     

    • Arbitrary waveforms at 800MS/s sampling rate and 16-bit vertical resolution
    • Extensive internal/external modulation of all waveform types
    • Linear and logarithmic sweeps of all waveform types
    • Front panel mounted USB Flash drive interface
    • GPIB (option), USB and LXI compliant LAN interfaces
    • Triggered (burst count) or gated operation using internal or external trigger sources

     


Showing 1–16 of 22 results