1 800 665 7301 | info@tmetrix.com

Uncategorized

Showing 1–16 of 19 results


    • Versatile Current Sensing: Accurately measure small and large currents, from sub-milliamp levels to thousands of amps.
    • High-Speed Pulse Monitoring: Patented distributed termination technology enables ultra-fast rise time measurement (as short as 2ns).
    • Enhanced Noise Immunity & Safety: Double shielding minimizes external noise, making these monitors ideal for high-voltage applications.
    • Robust Construction: Sealed models are suitable for high-voltage insulating oil or vacuum environments.
    • Broad Compatibility: Works with oscilloscopes, spectrum analyzers, power analyzers, digital voltmeters, ADCs, and more.

     

  • High-Precision Current Measurement with BNC Connectivity

    • Precision Current Sensing: ±1% accuracy ensures reliable real-time current monitoring.
    • BNC Connector for Seamless Connectivity: Works with oscilloscopes, ADCs, spectrum analyzers, and power analyzers.
    • Clamp-On Design for Non-Intrusive Measurement: Safely monitor live current flow without circuit disruption.
    • 50 Ohm Termination Compatible: Output reduces by half when using a 50Ω termination.
    • High-Voltage Safety Considerations: Conductive case requires adequate insulation for user safety.

     

  • High-Precision Voltage Measurement Up to 500kV

    • High-Voltage Measurement Capability: Supports up to 500kV in insulating oil and customizable calibration for air use.
    • Precision Division Ratios: Models with 5000:1, 10,000:1, and custom ratios, ensuring reliable voltage scaling.
    • Temperature-Compensated Accuracy: ±1% over 20°C to 80°C, providing stable voltage readings.
    • Robust Design for Harsh Environments: Sealed for high-voltage insulating oil use, with custom air calibration available.
    • Safe Operation with Ground Loop Control: The outer conductor is isolated from the case, allowing controlled grounding connections.

     

  • Precision Pulse Output Up to 500kV

    • Wide Voltage Range: Supports 100kV to 500kV pulse outputs for high-energy applications.
    • Fast Pulse Transmission: Pulse durations from 0.25 to 50 microseconds, ensuring efficient energy transfer.
    • Insulating Oil Immersion: Open-construction design for operation in high-voltage insulating oil, reducing breakdown risks.
    • Advanced Overvoltage Protection: Designed with built-in safety factors (50-100%) to prevent damage from overvoltages.
    • Reliable Flashover Protection: Corona ring-to-core insulation prevents damage from accidental flashovers.

     

  • Phase -Models Kitted for installation into End User’s Cabinet  and Phase -Models including Cabinet and Emergency Power off  (EPO)1

     

  • AC, DC, AC+DC, Single and Three – Phase -Models Including Cabinets

    Rated Power 60,000 (vA),  Output Power 21,000(w)  Output form  1,2,3Ø, Output Volt-Max 300(L-N)/425 (VAC/VDC)(1), Output AMPS/PHS 166.7 / 83.3 (AAC/ADC)(2), Input Power Form (3) 3 Ø, Panel Height (4) 27 (U) and Weight 527/240 (LBS./KG).

     

  • AC, DC, AC+DC, Single and Three – Phase -Models Including Cabinets

    Rated Power 30,000 (vA),  Output Power 21,000(w)  Output form  1,2,3Ø, Output Volt-Max 300(L-N)/425 (VAC/VDC)(1), Output AMPS/PHS 125.0 / 62.5  (AAC/ADC)(2), Input Power Form (3) 3 Ø, Panel Height (4) 27 (U) and Weight 466/212 (LBS./KG).

     

  • AC, DC, AC+DC, Single and Three – Phase -Models Including Cabinets

    Rated Power 30,000 (vA),  Output Power 21,000(w)  Output form  1,2,3Ø, Output Volt-Max 300(L-N)/425 (VAC/VDC)(1), Output AMPS/PHS 25.0/13.9 (AAC/ADC)(2), Input Power Form (3) 3 Ø, Panel Height (4) 15 (U) and Weight 320/146(LBS./KG).

     

  • AC, DC, AC+DC, Single and Three – Phase -Models without Cabinets

    Rated Power 15000 (vA),  Outputform  1,2,3Ø, Output Volt-Max 300(L-N)/425 (VAC/VDC)(1), Output AMPS/PHS 41.7 / 21.0 (AAC/ADC)(2), Input Power Form (3) 3 Ø, Panel Height (4) 4 (U) and Weight 112/51 (LBS./KG).

     

  • AC, DC, AC+DC, Single and Three – Phase -Models without Cabinets

    Rated Power 15000 (vA),  Outputform  1,2,3Ø, Output Volt-Max 300(L-N)/425 (VAC/VDC)(1), Output AMPS/PHS 41.7 / 21.0 (AAC/ADC)(2), Input Power Form (3) 3 Ø, Panel Height (4) 4 (U) and Weight 112/51 (LBS./KG).

     

  • AC, DC, AC+DC, Single and Three – Phase -Models without Cabinets

    Rated Power  12000 (vA),  Outputform  1,2,3Ø, Output Volt-Max 300(L-N)/425 (VAC/VDC)(1), Output AMPS/PHS  33.3/16.7 (AAC/ADC)(2), Input Power Form (3) 3 Ø, Panel Height (4) 4 (U) and Weight 112/51 (LBS./KG).

     

  • AC, DC, AC+DC, Single and Three – Phase -Models without Cabinets

    Rated Power  9000 (vA),  Outputform  1,2,3Ø, Output Volt-Max 300(L-N)/425 (VAC/VDC)(1), Output AMPS/PHS 0/13.9 (AAC/ADC)(2), Input Power Form (3) 3 Ø, Panel Height (4) 4 (U) and Weight 112/51 (LBS./KG).

  • AC, DC, AC+DC, Single and Three – Phase -Models without Cabinets

    Rated Power  9000 (vA),  Outputform  1,2,3Ø, Output Volt-Max 300(L-N)/425 (VAC/VDC)(1), Output AMPS/PHS 25.0/13.9 (AAC/ADC)(2), Input Power Form (3) 3 Ø, Panel Height (4) 4 (U) and Weight 112/51 (LBS./KG).

     

  • The AFX Series is a family of high power, single, split and three phase, AC, DC and AC+DC output capable Power Sources. Available models range from 9 kVA to 60 kVA. Using a modern user interface for ease of use, the AFX Series is cost effective and fully programmable for both basic frequency conversion and advanced AC power line or DC Download the Brochurepower disturbance test applications.

     

  • Rugged, 4-Port, High-Powered USB Hub

    • Ultra low noise for optimal performance of audio and video recording equipment
    • Durable cast-aluminum housing suitable for the most rugged environments
    • Oversized power source guaranteed to support current intensive USB peripherals on all 4 ports simultaneously
    • DVM probe port access for monitoring USB device load current on port 1
    • AC/DC wall adapter and USB host cable provided

     

  • 1 – 12 GHz Programmable Phase Shifters

    • USB powered and controlled

    • Includes easy to install and use GUI

    • 360 degree phase control in 1 degree increments

    • Calibrated performance for optimal accuracy

    • Phase profile upload capability

    • API DLL and example programs included

    pdf

    Data Sheets

     