Description
The Hioki IM3590 is a versatile and precision-focused Chemical Impedance Analyzer designed specifically for R&D professionals working with electrochemical components, materials, batteries, and EDLCs (Electric Double-Layer Capacitors). With a broad frequency range of 1 mHz to 200 kHz and ±0.05% basic accuracy, this instrument delivers highly detailed and reliable impedance analysis for both component-level testing and advanced research.
This all-in-one solution enables high-speed LCR and sweep measurements, internal battery impedance testing without load, and rapid analysis with sweep times as fast as 2 ms. Researchers benefit from advanced functions including Cole-Cole plot generation, equivalent circuit analysis, and multi-point time interval measurement—ideal for studying behavior over time under varying environmental conditions.
Whether you’re analyzing ion transport and charge transfer resistance in batteries or evaluating frequency characteristics of piezoelectric and resonant elements, the IM3590 offers unmatched functionality in a compact, lab-friendly package.
Basic specifications of CHEMICAL IMPEDANCE ANALYZER IM3590:
Specifications | Deatils | |||||
Measurement modes | LCR mode, Continuous measurement mode (LCR mode / Analyzer mode), Analyzer mode (Sweeps with measurement frequency and measurement level, temperature characteristics, equivalent circuit analysis) | |||||
Measurement parameters | Z, Y, θ, Rs (ESR), Rp, Rdc (DC resistance), X, G, B, Cs, Cp, Ls, Lp, D (tanδ), Q, T, σ (conductivity), ε (dielectric constant) |
|||||
Measurement range | 100 mΩ to 100 MΩ, 10 ranges (All parameters are determined according to Z) | |||||
Display range | Z, Y, Rs, Rp, Rdc, X, G, B, Ls, Lp, Cs, Cp, σ, ε : ±(0.00000 [unit] to 9.99999G [unit], Absolute value display for Z and Y only θ : ±(0.000° to 180.000°), D : ±(0.00000 to 9.99999) Q : ±(0.00 to 99999.9), Δ % : ±(0.0000% to 999.999%) T : -10.0°C to 99.9°C σ, ε :±(0.00000f [unit] to 999.999G [unit] |
|||||
Basic accuracy | Z: ±0.05% rdg. θ: ±0.03° | |||||
Measurement frequency | 1 mHz to 200 kHz (5 digits setting resolution, minimum resolution 1 mHz) | |||||
Measurement signal level | Normal mode: V mode/CV mode: 5 mV to 5 Vrms, 1 mVrms steps CC mode: 10 μA to 50 mArms, 10 μArms steps Low impedance high accuracy mode: V mode/CV mode: 5 mV to 2.5 Vrms, 1 mVrms steps CC mode:10 μA to 100 mArms, 10 μArms steps |
|||||
Output impedance | Normal mode: 100 Ω, Low impedance high accuracy mode: 25 Ω | |||||
Display | 5.7-inch color TFT, display can be set to ON/OFF | |||||
Measurement time | 2 ms (1 kHz, FAST, display OFF, representative value) | |||||
Functions | DC bias measurement, DC resistance temperature compensation (converted reference temperature is displayed), Temperature measurement, Battery mesurement (Automatic DC biasing system), Comparator, BIN measurement (classification), Panel loading/saving, Memory function | |||||
Interfaces | EXT I/O (Handler), USB communication (high-speed), USB memory Optional: Choose 1 from RS-232C, GP-IB, or LAN |
|||||
Power supply | 100 to 240 V AC, 50/60 Hz, 50 VA max. | |||||
Dimensions and mass | 330 mm (12.99 in) W × 119 mm (4.69 in) H × 168 mm (6.61 in) D, 3.1 kg (109.3 oz) | |||||
Included accessories | Power cord ×1, Instruction manual ×1, CD-R (Communication instruction manual and sample software [Communications control, accuracy calculation, and screen capture functionality] ) ×1 |