When high power quality matters, the new for 2020 LMX Series family of High Performance Linear AC Power Sources is the answer. The linear amplifiers within the LMX Series power sources are unmatched in their ability to produce the high crest factor, low-distortion, high fidelity output waveforms required by the most demanding AC Test Power applications. Stand-alone models range from 500 VA to 6 kVA. Larger chassis may be paralleled to create systems that range from 8kVA to 30 kVA. Offering both single and three phase models, units are conservatively designed with output power ratings are based on the most severe combination of input line, output voltage, power factor, and temperature.
Great emphasis has been placed on low acoustic noise, ease of installation, ease of use and safety. Control and operating features provide a high degree of application versatility and ease of use for the test engineer. Applications range from simple, manually controlled frequency conversion to power-line susceptibility testing and sophisticated bus programmable transient simulation.
The exceptionally broad bandwidth (50 kHz small signal), combined with low output impedance and high crest factor ratings give the LMX Series the ability to produce high quality, low distortion output power into the most dynamic loads.
The LMX Series encompasses an all new collection of High Performance 1 phase and 3 phase Linear AC Power Sources. All standard models operate from 15 to 5,000 Hz, range in power from 500VA to 30kVA, and provide nominal output voltage ranges up to 600Vrms L-N.
The LMX Series builds on the popularity of the original AMX Series linear AC power sources that have been the benchmark for programmable AC Power output fidelity and performance and are backward compatible with the AMX.
Design Provides Total Control of AC Power
ACA TMetrix Inc. is a leading Canadian distributor of test and measurement instruments and design tools. For over 55 years we have provided products manufactured by the world’s leading instrument manufacturers. Leading Distributor of Design Tools and Test Equipment in Canada.
Output Frequency | 15 to 5000 Hz. Full Power |
Line Regulation: |
0.1% max for a 10% line change |
Load Regulation: |
0.25% 15 to 2000 Hz. 0.5% 2000 to 5000 Hz. Can be improved to less than 0.03% with CSC engaged |
Output Distortion (Vthd): |
3U Models: 15~450 Hz: < 0.1%; 450~5000 Hz: < f x 0.076% + 0.07% (f in kHz) 5U & 8U Models: 45~1,000Hz: < 0.1% 1,000~5,000 Hz: < 0.25% |
Ripple and Noise: |
< 50 mVrms |
Response Time: | 5µsec. typical to a step load change. |
Small signal bandwidth: | 5 Hz. to 50 kHz, typical. |
LMX Controller |
|
Mechanical Specifications |
15.00 to 5000 Hz ±0.01% |
Voltage (Direct): | Programmable, 0-VMAX, in 0.1 volt steps (see table). |
Phase Angle: | Phase Angle (f) of Phases B and C relative to Phase A is programmable from 0-359° in 1° increments ± 0.5°. |
Current Limit: | Current limit is programmable from 0 to I peak maximum of the power source. Accuracy is ± 0.5%, resolution ±10mA |
Waveform Library: | Stores up to 200 waveforms that can be edited and executed in any manner and in any output phase. |
Voltmeter: |
Range: 0-340 volts L-N, 0-600 volts L-L Resolution: 0.10VAC to front panel, 0.001VAC to remote interface Accuracy: ±0.1% of range |
Ammeter: |
Range: 100% of system current rating Resolution: 0.01 Arms Accuracy: ± (0.5% + f (kHz) * 0.5%) F.S. |
Power Meter: |
Range: Based on ammeter range Resolution: 1 W, 1 VA (front panel) or 0.1 W, 0.1 VA remote control Accuracy: ± 0.75% of Full Scale |
Power Factor & Crest Factor: | Calculated and displayed to four significant digits. |
The LMX controller is essentially a single or three phase AC arbitrary waveform generator and Precision AC metering system. The waveform for each phase may be independently selected and may be independently varied in amplitude and phase angle with respect to phase A (3 phase systems).
The metering function samples the output volts and amps at 1024 samples per measurement using a 16 bit A/D converter. This technique provides exceptional metering accuracy and resolution and delivers a high-fidelity waveform back to a host computer for analysis.
The LMX includes LAN, USB, IEEE 488.2 and RS232 interfaces using SCPI commands.