Regatron TopCon TC.ACS Full 4-quadrant grid simulators, ‘HIL mode’ 4-quadrant voltage amplifier, Programmable RLC load mode

Regatron TopCon TC.ACS Full 4-quadrant grid simulators, ‘HIL mode’ 4-quadrant voltage amplifier, Programmable RLC load mode

  • compact and completely modular design
  • high effectiveness in all operation modes, few requirements on building infrastructure
  • ability to use an existing liquid cooling system directly
  • optional matched liquid-to-air cooling unit TC.LAE available
  • possibility of upgrading to systems of up to 1 MVA
  • high level of system dynamics, ≤ 5 kHz modulation bandwidth
  • non-restrictive capability of refeeding in the Q4 operation mode
  • possibility of operating as an autonomous 4-Q and 3-phase quasi-analogue amplifier
  • possibility of “Hardware-in-the loop”-operation (HIL mode)
  • user friendly application software with pre-configured test patterns
  • possibility of integrating into a complete SAS simulation and test system
  • galvanic isolation available as an option without derating the simulator port data

 

REQUEST A QUOTE
SKU: Regatron TopCon TC.ACS Category:



Introducing the Regatron TopCon TC.ACS Full 4-quadrant grid simulators, ‘HIL mode’ 4-quadrant voltage amplifier, Programmable RLC load mode

REGATRON’s  3-in-1 full 4-Quadrant, Regenerative, Bidirectional Source & Sink Grid Simulators (Grid Simulator, Power Amplifier and AC load)‎ of the series TC.ACS are of a precisely engineered, high quality, modular design.

The latest multi-level inverter technology for high-resolution voltage / current patterns, allows the Simulator  to cover the entire fundamental frequency range from DC up to 1000 Hz and up to 5000 Hz modulation bandwidth. A specialized multi-processor core prepares all relevant voltage / current shapes in real-time to ensure a very stable phase relationship and event timing throughout. A specialized multi-processor prepares all relevant voltage/current shapes in real-time to ensure a very stable phase relationship and event timing.

 

Regatron TopCon TC.ACS Full 4-quadrant grid simulators, ‘HIL mode’ 4-quadrant voltage amplifier, Programmable RLC load mode



Regatron TopCon TC.ACS Full 4-quadrant grid simulators, ‘HIL mode’ 4-quadrant voltage amplifier, Programmable RLC load mode

Key Features

Programmable testing parameters

The multi-level inverter technology common with a remarkable high switching frequency opens up the way to a wide base frequency range from DC up to 1000Hz and an exceptionally high modulation bandwidth of 5 kHz. Therefore, harmonic distortion up to the 100th harmonic @ 50 Hz or the 83th harmonic @ 60Hz can be exactly reproduced, assisted by a comfortable Fourier tool. Of course, the system can easily and comprehensively be adapted to the various tasks to be carried out within the fields of R+D, laboratory, end-of-line testing and education. By means of the application software ACSControl, the user is enabled to program the following parameters:

  • variation of basic system voltages and frequency
  • settings of phase relationship
  • voltage drops in the whole network or individual drops per phase
  • micro ruptures and flickers
  • over- and under voltages
  • voltage asymmetries
  • superimposed harmonic and interharmonic voltage waveforms
  • variation of phase angles
  • special conditions for EMC testing
  • transition from feeding to refeeding operation and vice versa
  • analyses of energy flow

 



Key Benefits

Application example: TC.ACS as an element of a Test Lab equipment

Comprehensive testing equipment for solar inverters, among others, integrates not only the grid simulation but also an additional simulation system for photovoltaic cells. The programmable TopCon Quadro DC power supplies together with the optional TC.LIN postprocessors in combination with the software tool SASControl form a finely graduated modular PV simulation environment. By using this testing equipment a PV inverter device can be comprehensively tested regarding the photovoltaic issue as well as in terms of the grid feed-in aspect.


Regatron TopCon TC.ACS Full 4-quadrant grid simulators, ‘HIL mode’ 4-quadrant voltage amplifier, Programmable RLC load mode


Trust the Experts at ACA TMetrix Inc.

ACA TMetrix Inc. is a leading Canadian distributor of test and measurement instruments and design tools. For over 55 years we have provided products manufactured by the world’s leading instrument manufacturers. Leading Distributor of Design Tools and Test Equipment in Canada.

Specifications

Technical data TC.ACS basic units TC.ACS.30.528.4WR.S TC.ACS.50.528.4WR.S
Grid input 3 x 360-528 VAC +PE (no neutral)
Grid frequency range 48-62Hz
Grid input phase current, feeding 3x52Arms @ full load 3×85 Arms @ full load
Grid input power factor 1
Sim output topology 3L+active N (4 outputs)
Sim output voltage 3 x 0-305 Vrms nominal (L-N)
SIM output phase current (permanent, Inom) 3 x 0 – 43Arms nominal 3 x 0 – 72Arms nominal
Sim output frequency range 0-1000Hz; current derating between 0 and 16Hz
Module power 30kVA nominal 50kVA nominal
Overloadability 200% Inom up to 1s every 60s 150% Inom up to 10s every 600s
Sim port power factor 0 …1
Modulation bandwidth ≤ 5 kHz (up to the 83th harmonic at 60Hz)
Voltage control RMS @50/60Hz < 0.05% FS

 

Datasheet


Get in touch with us to inquire about our tailored consulting services.