Discount Products: Look through products available for a 25% – 50% discount in 2020. The items provided on a first come, first serve basis. View Discounted Products
Discount Products: Look through products available for a 25% – 50% discount in 2020. The items provided on a first come, first serve basis. View Discounted Products
The Vitrek 4700 Precision High Voltage Meter is the top choice when you require high voltage test equipment, the 4700 offers the highest level of measurement accuracy, yet is surprisingly easy to use. Vitrek has harnessed DSP technology to provide outstanding AC & DC voltage accuracy, stability and resolution. Performance that rivals traditional HV reference dividers, yet unlike the delicate HV divider, the 4700 provides instant, direct, high voltage measurements in a highly portable, compact and rugged bench top enclosure.
The 4700’s large, high resolution, color, touch graphic display simultaneously shows the AC and DC content of the voltage being measured and can plot readings from a few seconds to several days.
The Vitrek 4700 Precision High Voltage Meter offers the highest level of measurement accuracy when it come4s to high-voltage measurement equipment. Its color touch screen is surprisingly easy to use for set up and display of testing results. Vitrek leverages DSP technology to provide outstanding AC &DC high voltage measurement accuracy, stability, repeatability and resolution. The 4700 High Voltage Meter offers performance that rivals traditional high voltage reference dividers – yet unlike the tedious divider, the 4700 provides instant, direct, high voltage measurements in a highly portable, compact and rugged bench top enclosure.
The high voltage tester measures up to 10KV DC or rms AC directly and with available HV Smartprobes, the high voltage measurement range can be extended to 35KV, 70 KV, 100KV and 140KV.
Vitrek’s 4700 precisely measures voltages directly up to 10KV, right out of the box – with no external probes. That’s high enough for most of the HV sources out there. However, should you care to expand your high voltage measurement range – just add one or more of the available 35KV, 70KV, 100KV and 150KV SmartProbes™. The Vitrek SmartProbes™ each store their own calibration data which is down loaded when they are plugged in to the 4700 – this results in high accuracy, calibrated readings and allows any Vitrek SmartProbe™ to be used with any 4700 High Voltage Meter. The SmartProbe’s™ proprietary, ultra-low TC attenuator design minimizes self-heating – while its lower capacitance construction technology enhances AC performance. In addition to the direct input terminal the 4700 has two probe inputs – use one probe to extend your measurement range or use two probes for making high voltage differential measurements.
Measurement integrity is our bottom line – whether you are on a production line manufacturing high voltage medical imaging equipment, in a national laboratory conducting ground breaking research or in the cal lab certifying test equipment, it is essential to choose your high voltage measurement equipment carefully. To insure the best possible measurement accuracy, the 4700 makes over 40,000 reading per second which are then filtered, sub-sampled, scaled and offset corrected – all with “error free” mathematic methodology. The True RMS AC readings are as true as they come, while the DC measurements offer rocket fast settling with rock solid stability. In addition to this, the 4700 provides VLF AC readings down to 0.01 Hz, as well as, peak to peak, crest factor and fundamental frequency measurement. Available G series probes offer extremely high input impedance options for electrostatic voltmeter applications.
With Vitrek’s high voltage test automation feature, you can automate your HV test requirement with the 4700’s built-in Ethernet port, high speed serial communication port or available GPIB. The 4700 is fully programmable – so you can select your measurement mode and bandwidth, then take readings as often as desired. The 4700 high voltage tester also comes standard with a USB printer port, to capture readings and get hardcopy printouts of HV plots – so you can document the sag or overshoot in a typical hipot test.
The 4700 and probes come with an ISO 17025 accredited calibration certificate with data at no charge. Vitrek is accredited to ISO 17025 by A2LA. Consider Vitrek at the forefront when it comes to your annual calibrations for the 4700 and probes.
ACA TMetrix Inc. is a leading Canadian distributor of test and measurement instruments and design tools. For over 55 years we have provided products manufactured by the world’s leading instrument manufacturers. Leading Distributor of Design Tools and Test Equipment in Canada.
For full specifications, please see the Operator’s manual available in the Downloads tab.
Maximum Voltage Measurement (Input Impedance) | |
---|---|
Direct Input Terminal | 10KVDC, 10KVACrms (110 Meg ohms) |
HVL-35 / HVP-35 Probe | 35KVDC, 30KVACrms (200 Meg ohms) |
HVL-35G Probe | 35KVDC (10 Gig ohms) |
HVL-70 Probe | 70KVDC, 50KVACrms (400 Meg ohms) |
HVL-70G Probe | 70KVDC (20 Gig ohms) |
HVL-100 Probe | 100KVDC, 75KVACrms (600 Meg ohms) |
HVL-100G Probe | 100KVDC (30 Gig ohms) |
HVL-150 Probe | 140KVDC, 100KVACrms (1000 Meg ohms) |
DC Voltage Measurement Accuracy (Resolution) | |
---|---|
Direct Input Terminal | 0.03% of reading + 0.03V (10mV) |
HVL-35 / HVP-35 Probe | 0.035% of reading + 0.07V (100mV) |
HVL-35G Probe | 0.25% of reading + 1.5V (1V) |
HVL-70 Probe | 0.04% of reading + 0.2V (1V) |
HVL-70G Probe | 0.35% of reading + 3.5V (1V) |
HVL-100 Probe | 0.05% of reading + 0.3V (1V) |
HVL-100G Probe | 0.5% of reading + 15 (10V) |
HVL-150 Probe | 0.08% of reading + 0.7V (10V) |
AC Voltage Measurement Accuracy (Resolution) | |
---|---|
Direct Input Terminal | 0.12% of reading + 0.1V (10mV) |
HVL-35 / HVP-35 Probe | 0.1% of reading + 0.2V (100mV) |
HVL-70 Probe | 0.1% of reading + 0.4V (1V) |
HVL-100 Probe | 0.1% of reading + 0.6V (1V) |
HVL-150 Probe | 0.5% of reading + 1V (10V) |
High Voltage Self Heating Effect | |
---|---|
Direct Input Terminal | 1.5 ppm of reading per KV2 |
HVL-35 / HVP-35 Probe | 0.4 ppm of reading per KV2 / 0.75 ppm of reading per KV2 |
HVL-70 Probe | 0.14 ppm of reading per KV2 |
HVL-100 Probe | 0.14 ppm of reading per KV2 |
HVL-150 Probe | 0.2 ppm of reading per KV2 |
General Specifications | |
---|---|
AC/DC Voltage Measurement Resolution | Selectable 4, 5 or 6 digits |
Measurement Functions | DC Voltage, True RMS AC Voltage, Ripple, Peak to Peak, Crest Factor & Frequency Measurement (4 digits 0.01 Hz to 600Hz) |
Measurement Time | Selectable down to 16mS (60 readings per sec.) |
Maximum Input to Common Terminal | 3 KV Peak for 1 sec, no damage |
Accuracy Specifications | Valid one year ± 5C from Cal temperature |
Interfaces | LAN (Ethernet), RS232/Serial and USB printer port standard. GPIB optional. |
Environmental/Physical | |
---|---|
Operating Environment | 0 to 50C, <85% RH (non-condensing) |
Dimensions | 218mm (8.5″) wide x 130mm (5″) high x 253mm (10″) deep, nominally |
Weight | 2.4kg max (4kg shipping) |
Power | |
---|---|
AC Source | 45 to 450Hz, 100 to 265Vrms at |
DC Source | 11 to 16Vdc at <1.2A, using a center positive 2.5mm DC power connector |
BP-47 Battery Option | Up to 11 hours continuous operation |
The 4700 is shipped with an ISO 17025 cal cert with data and uncertainties, direct input test leads, chassis ground lead, operator’s manual, and external power supply. All probes ship with an ISO 17025 cal cert with data and uncertainties. The HVP handheld probes comes with a detachable probe tip and the HVL series probes ship with a toroid corona shield.
3 year extended parts and labor warranty with no charge registration and annual factory calibration. 1 year standard warranty.