1 800 665 7301 | info@tmetrix.com

  • The Hioki MR6000 Memory HiCorder sets a new benchmark in waveform recording, combining cutting-edge technology, intuitive design, and world-class performance. Built from the ground up, it’s engineered to tackle both current and future measurement challenges with ease and precision.

    Key Features:

    • Large, intuitive touch panel for efficient and user-friendly operation
    • Simultaneous multi-channel isolation measurement at up to 200 MS/s (with High Speed Analog Unit U8976)
    • Significantly faster data saving for a seamless experience
    • Real-time data saving without interrupting ongoing measurements
  • The Hioki Rack-mounted Multi-channel System Recorder (MR8741/MR8740) is a powerful, high-speed, single-device solution for waveform recording and generation. Ideal for test systems, it offers high-resolution, isolated multi-channel measurements with fast sampling capabilities.

    Key Features:

    • Integrated waveform recording and generation in one device
    • Equipped with DVM Unit MR8990 for high-accuracy 24-bit resolution measurements
    • Supports up to 16 channels (MR8741) for multi-channel testing
    • Isolated input between channels and from input to chassis (up to 300 V AC/DC)
    • High-speed sampling up to 20 MS/s
    • Compact rack-mountable design (4U height, under 180 mm depth)
    • Monitor display and setting access via DVI-D and mouse
    • Enables remote measurement and control via LAN
    • Browser-based screen monitoring or advanced control via Hioki 9333 LAN Communicator
  • The Hioki Memory Recorder is a high-speed, fully-isolated data acquisition system designed for precise and simultaneous measurement of multiple analog and logic signals. Ideal for testing, simulation, and system diagnostics, it combines waveform generation and recording in one powerful unit.

    Key Features:

    • Generate and record waveforms using a single device
    • Simulate issues by outputting previously recorded problematic waveforms to test devices
    • Supports 32 analog + 32 logic channels, expandable to 28 analog + 64 logic channels
    • High-speed sampling up to 20 MS/s with fully isolated inputs
    • Ensures safe measurement with complete analog input isolation
    • Equipped with a large-capacity 512M-word memory
    • Simultaneously measures high voltage and ultra-low voltage system signals

     

  • High-Precision Current Measurement with BNC Connectivity

    • Precision Current Sensing: ±1% accuracy ensures reliable real-time current monitoring.
    • BNC Connector for Seamless Connectivity: Works with oscilloscopes, ADCs, spectrum analyzers, and power analyzers.
    • Clamp-On Design for Non-Intrusive Measurement: Safely monitor live current flow without circuit disruption.
    • 50 Ohm Termination Compatible: Output reduces by half when using a 50Ω termination.
    • High-Voltage Safety Considerations: Conductive case requires adequate insulation for user safety.

     

  • Single-phase, 2U, industrial amplifier/battery simulator

    • Bench-sized
    • Powered from 120V/230VAC
    • Source and Sink (4 quadrant)
    • Rugged Design
    • 3-Year, No-Fault Warranty

    Key Performance Capabilities:

    • Drop outs and surges as fast as 1.2µs
    • Small signal response up to 1 MHz
    • 13.5 VDC at up to 28A
    • Field-selectable ±40V, 75V or 150V potential

     

  • Max. 108 Analog Channels, Reduce Inspection Data Transfer Time to Zero

    Key Features of HiCORDER MR8740T – High-Speed Data Acquisition:

    • Ideal for multipoint inspection of high performance boards such as ECU
    • 108ch analog to 96ch analog + 48ch logic input
    • Reduce time required to save to external media to max.1/100 compared with conventional method
    • 20 MS/s simultaneous sampling on all channels
    • Safe measurement with all analog inputs isolated
    • Supports 4K monitor to display multi-channel waveforms without overlapping
    • Measure 4 channels with 1 unit (4 ch analog Unit U8975, 4 ch DVM Unit U8991)
    • Generate constant voltage, constant current, and simulated resistance (VIR Generator Unit U8794)

     

  • High-speed 20 MS/s (*1), 32-channel, Fully Isolated Memory Recorder for On-site Jobs and R&D

    Key Features:

    • Supports a wide variety of measurements with a total of 17 plug-in modules
    • Generate and record with a single unit
    • Direct 1000 V high voltage input testing
    • High-speed sampling up to 20MS/s (*1) with fully isolated inputs
    • 32 analog channels + 16 logic ch to 20 analog channels + 64 logic ch
    • High-speed sampling with waveform judgement function
    • Soil-resistant construction strong against adverse working environments
    • Big buttons coated to withstand industrial oil and residue
    • Drop-in paper loading and one-touch setup, along with high-speed 50mm/s printing

     

    • High speed sampling of 5 MS/s ensures catching high speed phenomena
    • Isolated 4 channel input
    • Max. rated voltage to ground: 300 V AC or DC (CAT II)
    • High resolution measurement with 16 bit A/D
    • For Memory HiCorder MR6000 and MR8740T

     

  • HDO4000A oscilloscopes have 4 analog input channels, 12-bit resolution using Teledyne LeCroy’s HD4096 high-definition technology, up to 1 GHz of bandwidth and a compact form factor with a large 12.1” multi-touch display. They are ideal for debug and troubleshooting of power electronics designs, digital power management or power integrity analysis, automotive electronics systems, and deeply embedded or mechatronic designs.

     

  • The WaveSurfer 3000z has a 10.1″ capacitive touch display, the longest memory, and the deepest toolbox – all at an affordable price.

    • HD4096 technology provides 12-bit resolution all the time
    • 2ProBus input supports over 30 probes in 9 product categories
    • 3Long record capture of up to 25 Mpts
    • 412.1” 1280 x 800 HD capacitive touchscreen
    • 5Mixed-signal capability – debug complex embedded designs with integrated 16-channel mixed signal option
    • 6Easy connectivity with 2 USB 3.1 ports
    • 7MAUI with OneTouch user interface for intuitive and efficient operation

     

    • 15.6″ 1920 x 1080 capacitive touchscreen display
    • 24 analog input channels
    • 3ProBus input supports every Teledyne LeCroy probe
    • 4MAUI with OneTouch user interface for intuitive and efficient operation
    • 5Q-Scape multi-tab display architecture
    • 6Up to 250 Mpts of acquisition memory
    • 7HD4096 technology – 12 bits all the time
    • 8Buttons/indicators color-coded to associated waveform on display
    • 9Use cursors and adjust settings without opening a menu
    • 10Mixed Signal capability with 16 integrated digital channels
    • 116 USB 3.1 ports (2 front, 4 side)

     

    • HD4096 technology provides 12-bit resolution up to 8 GHz and 20 GS/s
    • Up to 5 Gpts of acquisition memory enables detailed viewing of long events
    • 15.6” 1900 x 1080 Full HD capacitive touchscreen
    • ProBus2 input supports up to 8 GHz bandwidth while maintaining support for legacy ProBus probes
    • MAUI with OneTouch user interface for intuitive and efficient operation
    • Waveform Control Knobs – Control channel, zoom, math and memory traces with the multiplexed vertical and horizontal knobs
    • Color-coded panel indicators – Trigger, horizontal and vertical indicator colors correspond to the associated waveform on the display
    • Cursor/Adjust Knobs – Enable and position cursors or adjust settings and parameters without opening a menu
    • Mixed Signal Capability – Debug complex embedded designs with integrated 16-channel mixed signal capability
    • Easy connectivity with seven USB 3.1 ports (3 front, 4 side) and UHD (4k) HDMI and DisplayPort outputs

     

    • Eye diagram (a), eye mask failure (b) and IsoBER eye opening analysis (c)
    • Jitter spectrum (a) with noise floor display (b) and inverse FFT of the periodic jitter (c)
    • Data dependent jitter (DDj) plot for each bit in synch with pattern (a) and with histogram (b)
    • Time interval error (TIE) jitter track analysis
    • Jitter histograms (a) with bathtub curves (b) and CDF plot (c)
    • Intersymbol interference (ISI) plots pinpoint bit sequences that have high ISI and are sources of bit errors
    • Jitter measurements table with full details for one or more “lanes” plus reference

     

    • 15.6” 1920 x 1080 capacitive touchscreen display
    • 8 analog input channels
    • ProBus input supports every Teledyne LeCroy probe
    • MAUI with OneTouch user interface for intuitive and efficient operation
    • Q-Scape multi-tab display architecture
    • Up to 5 Gpts of acquisition memory
    • HD4096 technology – 12 bits all the time
    • Buttons/indicators color-coded to associated waveform on display
    • Use cursors and adjust settings without opening a menu
    • Mixed Signal capability with 16 integrated digital channels
    • 6 USB 3.1 ports (2 front, 4 side)
    • HDMI and DisplayPort – supports 4K (4096 x 2304) external monitor
    • Removable SSD (standard)
    • View 16 channels on one display with OscilloSYNC
    • Reference Clock Input/Output for connecting to other equipment
    • USBTMC over USB 3.1 for fast data offload

     

    • 4/8 analog channels + 1 external trigger
    • Analog channel bandwidth: up to 2 Ghz; real-time sampling rate of up to 10 GSa/s
    • Vertical resolution: 12-bits
    • Low noise floor: 153 μVrms at full bandwidth of 2 GHz
    • New generation of high speed display technology:
      • Waveform capture rates up to 170,000 wfm/s (normal mode), and 750,000 wfm/s (sequence mode)
      • Supports 256-level intensity grading and color temperature display modes
      • Memory depth up to 500 Mpts/channel
      • Digital trigger system
    • Intelligent trigger: Edge, Slope, Pulse, Window, Runt, Interval, Dropout, Pattern, Qualified, Nth edge, Setup/hold, Delay and Video (HDTV supported)
    • Serial bus triggering and decoder, supports protocols I2C, SPI, UART, CAN, LIN, CAN FD, FlexRay, I2S, MIL-STD-1553B, SENT and Manchester as standard
    • Segmented acquisition (Sequence) mode, dividing the maximum record length into multiple segments (up to 80,000), according to trigger conditions set by the user, with a very small dead time between segments to capture the qualifying event
    • History waveform record (History) function, the maximum recorded waveform length is 80,000 frames
    • Automatic measurements on 50+ parameters, supports statistics with histogram, track, trend, Gating measurement, and measurements on Math, History, Memory and Ref
    • 4 Math traces (8 Mpts FFT, addition, subtraction, multiplication, division, integration, differential, square root, etc.), supports formula editor