1 800 665 7301 | info@tmetrix.com

  • A high-performance analyzer designed for R&D applications involving electrochemical components, materials, batteries, and EDLCs. It enables precise impedance measurements essential for advanced evaluation and development.

    Key Features:

    • Wide frequency range: 1 mHz to 200 kHz for detailed ion and solution behavior analysis
    • Dual function: High-speed continuous LCR and sweep measurements with one device
    • Battery analysis: Measures internal impedance under no-load conditions
    • Ultra-fast sweep: Perform measurements in as little as 2 ms
    • High accuracy: ±0.05% basic precision for reliable R&D and testing
    • Advanced analysis: Supports Cole-Cole plots and equivalent-circuit modeling for electrochemical studies
  • An advanced firmware upgrade for the IM3570 that enables quick and accurate equivalent circuit analysis, ideal for in-depth component evaluation and quality control.

    Key Features:

    • Automatically selects the optimal equivalent circuit model from five typical options
    • Minimizes discrepancies between measured and ideal frequency characteristics
    • Determines acceptance/rejection of L, C, and R elements with precision
    • Evaluates resonance sharpness (mechanical quality coefficient)
    • Enables detailed analysis of piezoelectric elements and inductors through resonance
  • The Hioki IM7580A is a compact, high-speed impedance analyzer for 1 MHz to 300 MHz testing, ideal for both production and R&D. It works seamlessly with the IM9201 SMD fixture for reliable component testing.

    Key Features:

    • 1 MHz to 300 MHz frequency range
    • 0.5 ms test speed
    • ±0.72% basic accuracy
    • Compact half-rack size with palm-sized test head
    • Reliable contact check functions
    • Frequency, level, and time sweeps in Analyzer Mode
    • RF I-V method for precise measurement
  • The Hioki IM7581 is a compact, high-speed impedance analyzer designed for accurate testing from 100 kHz to 300 MHz. It’s ideal for both production and development environments.

    Key Features:

    • 100 kHz to 300 MHz frequency range
    • 0.5 ms fastest test speed
    • ±0.72% basic accuracy
    • Compact half-rack size, palm-sized test head
    • Reliable contact check via DCR, Hi-Z reject, or waveform judgment
    • Supports frequency, level, and time sweeps in Analyzer Mode
    • Uses RF I-V method for precise measurement
  • The Hioki Impedance Analyzer IM7587 3 GHz provides precision, speed, and versatility for impedance measurements from 1 MHz to 3 GHz, ideal for both R&D and mass production applications in electronic component testing.

    Key Features:

    • Frequency range: 1 MHz to 3 GHz
    • Test speed: 0.5 ms
    • Measurement variability: 0.07%
    • Basic accuracy: ±0.65% reading
    • RF I-V measurement technique
    • Compact half-rack design with palm-sized test head
    • Robust contact check capabilities
    • Analyzer mode: frequency and level sweeps, time interval measurements
  • High-Precision Current Measurement with BNC Connectivity

    • Precision Current Sensing: ±1% accuracy ensures reliable real-time current monitoring.
    • BNC Connector for Seamless Connectivity: Works with oscilloscopes, ADCs, spectrum analyzers, and power analyzers.
    • Clamp-On Design for Non-Intrusive Measurement: Safely monitor live current flow without circuit disruption.
    • 50 Ohm Termination Compatible: Output reduces by half when using a 50Ω termination.
    • High-Voltage Safety Considerations: Conductive case requires adequate insulation for user safety.

     

  • Single-phase, 2U, industrial amplifier/battery simulator

    • Bench-sized
    • Powered from 120V/230VAC
    • Source and Sink (4 quadrant)
    • Rugged Design
    • 3-Year, No-Fault Warranty

    Key Performance Capabilities:

    • Drop outs and surges as fast as 1.2µs
    • Small signal response up to 1 MHz
    • 13.5 VDC at up to 28A
    • Field-selectable ±40V, 75V or 150V potential

     

  • Quantify composite layer resistance and interface resistance in Li-ion battery electrode sheets

    The RM2610 Electrode Resistance Measurement System is an advanced tool designed for precise quantification of composite layer resistivity and interface resistance in Li-ion battery electrode sheets. Using cutting-edge inverse problem analysis, the system isolates and calculates resistance values critical for optimizing battery performance. Its intuitive design includes a constant current source and a multi-probe setup, enabling rapid measurements and detailed analysis.

    With the ability to measure resistance variations caused by material properties, composition, and manufacturing conditions, the RM2610 accelerates the development of high-performance batteries. This system supports both positive and negative electrodes and provides visual insights into uniformity and density effects. Ideal for research and manufacturing environments, the RM2610 ensures reliable, accurate measurements essential for advancing lithium-ion battery technology.

     

  • Rapid 6.4ms Super Megohm and Low Current Testing

    Key Features

    • 300 times better noise resistance
    • Max. 1000 V output: SM7110
    • Max. 2 × 10^19 Ω display
    • Min. 0.1 fA resolution
    • Built-in EXT I/O, RS-232C, GP-IB and USB
    • Flexible, Multipurpose Design, High Resistance
    • Meter/Electrometer/Picoammeter/IR Meter
    • Measure resistance of materials by combining with optional electrode

     

  • HDO4000A oscilloscopes have 4 analog input channels, 12-bit resolution using Teledyne LeCroy’s HD4096 high-definition technology, up to 1 GHz of bandwidth and a compact form factor with a large 12.1” multi-touch display. They are ideal for debug and troubleshooting of power electronics designs, digital power management or power integrity analysis, automotive electronics systems, and deeply embedded or mechatronic designs.

     

  • The WaveSurfer 3000z has a 10.1″ capacitive touch display, the longest memory, and the deepest toolbox – all at an affordable price.

    • HD4096 technology provides 12-bit resolution all the time
    • 2ProBus input supports over 30 probes in 9 product categories
    • 3Long record capture of up to 25 Mpts
    • 412.1” 1280 x 800 HD capacitive touchscreen
    • 5Mixed-signal capability – debug complex embedded designs with integrated 16-channel mixed signal option
    • 6Easy connectivity with 2 USB 3.1 ports
    • 7MAUI with OneTouch user interface for intuitive and efficient operation

     

    • 15.6″ 1920 x 1080 capacitive touchscreen display
    • 24 analog input channels
    • 3ProBus input supports every Teledyne LeCroy probe
    • 4MAUI with OneTouch user interface for intuitive and efficient operation
    • 5Q-Scape multi-tab display architecture
    • 6Up to 250 Mpts of acquisition memory
    • 7HD4096 technology – 12 bits all the time
    • 8Buttons/indicators color-coded to associated waveform on display
    • 9Use cursors and adjust settings without opening a menu
    • 10Mixed Signal capability with 16 integrated digital channels
    • 116 USB 3.1 ports (2 front, 4 side)

     

    • HD4096 technology provides 12-bit resolution up to 8 GHz and 20 GS/s
    • Up to 5 Gpts of acquisition memory enables detailed viewing of long events
    • 15.6” 1900 x 1080 Full HD capacitive touchscreen
    • ProBus2 input supports up to 8 GHz bandwidth while maintaining support for legacy ProBus probes
    • MAUI with OneTouch user interface for intuitive and efficient operation
    • Waveform Control Knobs – Control channel, zoom, math and memory traces with the multiplexed vertical and horizontal knobs
    • Color-coded panel indicators – Trigger, horizontal and vertical indicator colors correspond to the associated waveform on the display
    • Cursor/Adjust Knobs – Enable and position cursors or adjust settings and parameters without opening a menu
    • Mixed Signal Capability – Debug complex embedded designs with integrated 16-channel mixed signal capability
    • Easy connectivity with seven USB 3.1 ports (3 front, 4 side) and UHD (4k) HDMI and DisplayPort outputs

     

    • Eye diagram (a), eye mask failure (b) and IsoBER eye opening analysis (c)
    • Jitter spectrum (a) with noise floor display (b) and inverse FFT of the periodic jitter (c)
    • Data dependent jitter (DDj) plot for each bit in synch with pattern (a) and with histogram (b)
    • Time interval error (TIE) jitter track analysis
    • Jitter histograms (a) with bathtub curves (b) and CDF plot (c)
    • Intersymbol interference (ISI) plots pinpoint bit sequences that have high ISI and are sources of bit errors
    • Jitter measurements table with full details for one or more “lanes” plus reference

     

    • 15.6” 1920 x 1080 capacitive touchscreen display
    • 8 analog input channels
    • ProBus input supports every Teledyne LeCroy probe
    • MAUI with OneTouch user interface for intuitive and efficient operation
    • Q-Scape multi-tab display architecture
    • Up to 5 Gpts of acquisition memory
    • HD4096 technology – 12 bits all the time
    • Buttons/indicators color-coded to associated waveform on display
    • Use cursors and adjust settings without opening a menu
    • Mixed Signal capability with 16 integrated digital channels
    • 6 USB 3.1 ports (2 front, 4 side)
    • HDMI and DisplayPort – supports 4K (4096 x 2304) external monitor
    • Removable SSD (standard)
    • View 16 channels on one display with OscilloSYNC
    • Reference Clock Input/Output for connecting to other equipment
    • USBTMC over USB 3.1 for fast data offload