1 800 665 7301 | info@tmetrix.com

  • ✔ Available in 250 MHz & 350 MHz models
    ✔ 2, 4, and 8-channel options for multi-signal generation
    ✔ 16-bit vertical resolution for precise signal emulation
    ✔ Max sinewave frequency of 250 MHz & 350 MHz
    ✔ Wave Sequencing for complex test scenarios
    ✔ Mixed Signal Generation: Supports 8, 16, or 32 synchronized digital channels
    ✔ True Arbitrary Mode & Direct Digital Synthesis (DDS)
    ✔ Wideband output voltage window: ±24V (50Ω into High Impedance)
    ✔ Embedded noise simulation & jitter analysis
    ✔ Up to 1 Gpts of waveform memory per channel
    ✔ Seamless integration with LabVIEW™, MATLAB™, Python, and .NET

     

    • Channel Configurations: Available in 2, 4, and 8-channel models.
    • High Sampling Rate: Up to 12.32 GS/s in RF mode for high-frequency applications.
    • Superior Resolution: 16-bit vertical resolution for ultra-precise signal generation.
    • Waveform Memory: 4 Gpts per channel, ensuring long-duration complex waveform storage.
    • High Output Voltage: Up to 5 Vpp output voltage with ±2.5 V baseline offset (50 Ohm).

     

  • Multiple Bandwidth Options: 100 MHz, 200 MHz, and 350 MHz
    Fast Sampling Rate: Up to 2 GS/s (interleaved) for high-speed signal acquisition
    Extended Memory Depth: Up to 28 Mpts per channel for capturing intricate signal variations
    Serial Bus Trigger and Decode: Built-in support for I2C, SPI, UART, RS232, CAN, LIN
    Waveform Sequence Recorder: Capture and playback up to 80,000 recorded waveforms
    Advanced Triggering System: Includes Edge, Slope, Pulse Width, Window, Runt, Interval, and Pattern triggers
    Multi-Mode Display: Supports color temperature mapping and intensity grading for signal clarity
    MSO Upgrade Option: 16 digital channels available for mixed-signal debugging (on 4-channel models)
    Connectivity: USB, LAN, and external trigger output for remote data transfer and PC control

     

    • Bandwidth Options: 100 MHz, 200 MHz, 350 MHz, and 500 MHz.
    • Sampling Rate: Up to 2 GS/s (1 GS/s per channel in four-channel mode).
    • Memory Depth: Up to 200 Mpts in interleaved mode for extended signal capture.
    • High-Speed Capture: Waveform update rates of 120,000 wfm/s in standard mode and up to 500,000 wfm/s in sequence mode.
    • Advanced Triggers: Edge, Slope, Pulse Width, Window, Runt, Interval, Dropout, Pattern, and Serial triggering.
    • MSO Functionality: Optional 16 digital channels for mixed-signal analysis.
    • Waveform Recorder: History Mode allows users to store and replay up to 90,000 waveforms.
    • Comprehensive Math Functions: Includes FFT, differentiation, integration, and enhanced resolution modes.
    • 256-Level Intensity Grading: Color temperature display for identifying rare signal events.
    • Connectivity: USB Host, USB Device, LAN, and External Trigger support for seamless data transfer and remote control.

     

    • High Bandwidth & Sampling Rate: Models available in 200 MHz, 350 MHz, 500 MHz, and 1 GHz with up to 5 GS/s sample rate.
    • Deep Memory Capture: Up to 250 Mpts in interleaved mode, allowing detailed waveform analysis.
    • Advanced Triggering & Waveform Capture: Zone Triggering, History Mode (100,000 waveforms), and a waveform capture rate of 500,000 wfm/s.
    • Math & Measurement Functions: 9 basic math functions (FFT, addition, subtraction, multiplication, division, etc.) and 50+ automatic measurement parameters.
    • Bode Plot & Power Analysis: Standard features include Bode Plot for frequency response testing and comprehensive power analysis for applications like power quality assessment, current harmonics, inrush current, and switching loss.
    • Mixed Signal Debugging: Optional 16-channel MSO capability for digital signal acquisition.
    • Connectivity & Remote Access: USB, LAN, and embedded web server for remote control and data analysis.

     

    • Available in 4.5-digit (60,000 count) and 6.5-digit (2,200,000 count) resolutions.
    • Wide measurement range:
      • DC Voltage: Up to 1000V
      • AC Voltage: Up to 750V (True RMS)
      • Current: 10A (AC/DC)
      • Resistance: 100MΩ (2-wire/4-wire)
      • Capacitance: 2nF – 100mF
      • Temperature measurements with TC and RTD sensor support.
    • High-speed measurements:
      • T3DMM4-5: 150 readings per second
      • T3DMM6-5: 10,000 readings per second
    • Advanced mathematical functions such as Max, Min, Standard Deviation, dBm/dB, Relative Measurement, Pass/Fail Analysis, and Histograms.
    • Connectivity: USB Device, USB Host, and LAN for remote operation via SCPI commands.
    • Data Storage: 1GB NAND flash memory for saving configuration files and test data.
    • Built-in cold junction compensation for accurate temperature measurements.
    • File management system supporting U-disc and local storage for convenient data access.
    • Comprehensive user interface with a dual-display system for easy navigation.
    • Automatic measurement functions, including statistical analysis, gating, and reference functions.

     

  • Key Performance Capabilities:

    • Slew rates up to 60 V/µsec.
    • Up to 240A DC at +50VDC or –50VDC (4301-240 configuration).
    • Can provide pulses of up to 800 amps at voltages of up to ±100V (4301-240 configuration).
    • Adjustable compensation allows the system to maintain a 50V/2 µsec rise-time over a wide range of current outputs.

     

  • Key Performance Capabilities:

    • Bandwidth: DC to 50 kHz
    • Voltage: 0 to 250 VRMS; 0 to 350 VDC
    • Current: 100 to 500 ARMS
    • Distortion: 0.1%
    • Power: 4 kW to 20 kW*Power levels up to 5X rated power when driving reactive loads
    • High power efficiency and density

    *Models available with output from 4 kW to 20 kW (capable of up to 125 kVA).

     

  • Key Performance Capabilities:

    • 4-Quadrant – Can source and sink current
    • ±80V – DC supply for 12V to 48V systems; meets 80V surge requirements
    • 300 kHz Sine – DC ripple tests for all major standards
    • 3µs Rise Time – Exceeds surge and dropout slew rate requirements
    • 3mΩ DC Source Impedance – Out-performs ISO 7637-2 requirements
    • Supports ground reference and supply offset testing required for ISO 16750-2 Sect. 4.8 and other similar standards

     

  • Key Performance Capabilities:

    • Up to 900 watts RMS power output (7136 model)
    • Small signal response up to 400 kHz
    • User-adjustable precision DC offset
    • User-adjustable current limit: 1A to 25A
    • 4-quadrant operation
    • AC/DC coupled

     

  • Key Performance Capabilities:

    • Up to 900 watts RMS power output (7136 model)
    • Small signal response up to 400 kHz
    • User-adjustable precision DC offset
    • User-adjustable current limit: 1A to 25A
    • 4-quadrant operation
    • AC/DC coupled

     

    • Frequency Range 10 Hz – 1GHz, 3GHz or 6GHz
    • 4000x faster in your pre-certifcation work
    • compact design and +12V power supply
    • 162.5 MHz full gapless real-time analysis bandwidth
    • Weighted Real-time Spectrogram

     

    • requency Range from DC up to 40 GHz
    • 685 MHz Real-time analysis bandwidth
    • Dynamic range of more than 100 dB
    • Multi-GHz real-time scanning up to 40 GHz
    • all 6dB RBWs acc. to CISPR, MIL, DO, ANSI, FCC
    • fastest super-heterodyn receiver on the planet

     

  • High‐Resolution Portable TDR with Frequency‐Domain Analysis Tools

    Ideal for testing all types of microwave/RF and digital cables and connectors

    • Rugged portable TDR with S‐parameter tools
    • Resolves connector detail (<1 cm)
    • 75 μm (0.003 in.) cursor resolution
    • 16‐bit digital sampling at up to 250 KSPS
    • Stores thousands of TDR traces
    • USB host/client, 10/100 Ethernet
    • Lightweight, bright color screen
    • Internet streaming and remote control

     

  • Simplify Aging Aircraft Wiring Maintenance Using High-Resolution MOHR CT100 Series TDR Cable Analyzers

    • Designed for use with the high-resolution CT100 TDR Cable Tester
    • Ideal for TDR testing MIL-STD-1553B data bus aerospace cable assemblies
    • Detect and localize open, short, and partial cable and connector faults on the main bus and stubs
    • Detects cable and connector faults through 3+ transformer couplers
    • Simplifies troubleshooting of aging aircraft MIL-STD-1553 cable assemblies

     

  • Next-gen Time-Domain Reflectometers replace the Tektronix® 1502C

    The new CT100 and CT100HF are the industry’s highest-resolution portable metallic TDRs, designed for testing all coaxial and twisted-pair cables and interconnects used in modern microwave/RF and digital systems. These are the only portable instruments that exceed all TDR specifications of the Tektronix® 1502C Metallic TDR Cable Tester, while providing next-generation improvements in TDR analysis, data storage, connectivity, and ergonomics.

    CT100 Series TDRs feature 8-10x sharper spatial resolution and100-1000x better Distance-to-Fault (DTF) resolution than competing TDR instruments, and have multi-GHz bandwidth similar to competing FDR (Frequency-Domain Reflectometer) instruments with similar or better cable fault sensitivity andorders-of-magnitude better DTF precision.

    These instruments’ unique combination of fast system rise-time,high-resolution time-base, and precision 16-bit impedance measurements allow you to identify and correct subtle changes in cable and connector performance before system failure. Some of the CT100 Series’ innovative features are described below. Also, please read CT100 Series Features for more information.