1 800 665 7301 | info@tmetrix.com

    • Superior Noise Reduction – Attenuates up to 24 dBA, making it perfect for quiet office environments.
    • Efficient Cooling – Six ultra-quiet fans expel up to 3 kW of thermal heat.
    • Flexible Installation – Available in 24U, 35U, and 44U heights with 36” and 42” depths.
    • Durable Construction – Made from 12-gauge US-finished steel with a maximum load capacity of 2,000 lbs.
    • Comprehensive Security – Key lockable front and rear doors, with optional locking side panels.
    • Acoustic Lined Panels – Fully lined with sound-absorbing material for maximum noise control.
    • Versatile Color Options – Available in 7 standard colors including Black, Pearl White, Granite, Platinum, White, Dark Grey, and Blue.
    • Complete Accessibility – Removable side panels for easy installation and maintenance.
    • Integrated Temperature Display – Real-time temperature monitoring with remote sensor support.
    • Cable Management – Bottom rear cable entry accommodates up to 500 CAT 5 cables.

  • Ideal for:

    • Small & Medium Businesses – Deploy IT infrastructure without dedicated server rooms.
    • Edge Computing – Reduce latency and bandwidth strain with localized computing.
    • Secure Data Centers – Enhance equipment security & environmental control.

    With its compact footprint, advanced cooling, and soundproofing technology, the EDGE 3 enclosure offers a quiet, efficient, and scalable alternative to traditional server rooms.

  • Customizable Configurations for Any Environment

    • Freestanding cabinets with adjustable 19” EIA square hole rails and depths of up to 38”.
    • Wall-mounted units (cold-rolled steel or stainless steel) available in 12U and 19U sizes.
    • Outdoor-ready enclosures for harsh industrial conditions.

    Ideal for:

    • Telecom & Network Infrastructure
    • Industrial Automation & Edge Computing
    • Smart Grid & IoT Deployments
    • Military & Government Facilities

    The KARIS SRK Precision Cooling Cabinets are a space-saving, cost-effective solution for securely housing IT and industrial equipment while maintaining optimal environmental conditions.

    • Fully assembled design for hassle-free installation.
    • Hinged swing-out option for rear access to cables and equipment.
    • Adjustable rails and multiple cable management points.
    • Lockable side panels and glass doors for added security.
    • Compatibility with power, cooling, and shelving accessories.
    • Removable back panel for simplified mounting.
    • Durable black powder-coated finish with EIA 310-D compliance.

    The KARIS SRK Series Wall-Mount Cabinets provide an ideal solution for IT professionals and data centre managers looking for efficient, secure, and accessible equipment housing.

    • Noise reduction of up to 31 dBA, making servers whisper-quiet.
    • Up to 12 kW heat dissipation, ensuring optimal thermal management.
    • IoT-enabled U-Telligent Management System (UMS) for remote monitoring, security, and alerts.
    • Built-in security with internal camera mounting, electronic locking, and real-time access alerts.
    • Available in 12U, 24U, and 42U heights, supporting all major server brands.
    • Flexible installation options, allow for easy integration in offices, labs, and industrial settings.
    • Energy-efficient EC fans, dynamically adjust speed based on heat load to reduce energy costs.
    • Fully enclosed design with soundproof cable entry points, maintaining maximum acoustic performance.

     

  • Karis SRK Series Server Cabinets are a reliable way to keep sensitive electronics safe. The professional design features a ventilation rate of more than 74%, providing adequate cooling for the entire system. Karis’s server cabinets will make integrating your data center or data closet fast and easy.

    • Curved locking front door with ventilation rate above 80%
    • Split locking rear door with ventilation rate above 80%
    • Horizontally split locking side panels make access easy
    • Two heights, two depths, and two widths available
    • Rear vertical cable managers (two) include
    • Square hole mounting rails are adjustable front to rear
    • Grounding kit included
    • Levelers and heavy duty casters come standard
    • Full range of optional accessories
    • 5 year warranty

     

    • Customizable & savable test setups
    • Program & Datalog Storage
    • User Defined Temperature Limits
    • Local & Remote Operations
    • LabView™ drivers
    • IEEE-488, RS232 ports

     

     

    • 20 Amp Operation: Full performance with 20 amp service
    • Automatic Power Reduction: Reduces power usage during idle periods
    • Heat Only Mode: Reduces power usage when cold temperatures are not used
    • WhisperStream Technology: quieter, smooth-sounding operation, 56 dBA
    • Frost Free Test Environment: dry air purge for tester interface, prevents condensation:
      0.5 to 3scfm (0.25 to 1.5 l/s)
    • Heated Defrost: quickly removes moisture buildup from internal chiller
    • DUT Temperature Control : Proprietary control algorithm enables DUT temperature to be directly controlled
    • Transition Rate*
      -55 to +125°C, approx. 10 seconds
      125 to -55°C, approx. 10 seconds
    • System Airflow Output*
      4 to 18scfm (1.9 to 8.5 l/s) Continuous
    • Temperature Range*
      -80 to +225°C (60Hz) No LN2 or LCO2 Required

     

    • High reliability thermal cycling without thermoelectric modules
    • Temperature range: -65 to 175°C
    • Cooling power:
      • 40W at -40°C for lower power devices
      • 55W at -55°C and 120W at -40°C.
    • Transition rate: up to <35 sec over 25 to -40°C
    • Easy and secure thermal connection to in-circuit or test socked DUT
    • Touch-screen controller: user-programmable temperatures, graphing, data logging
    • Communications options: Ethernet, USB, IEEE, RS232

     

  • -60° to +200°C

    • Economy model with high thermal capacity
    • Precise temperatures with fast transitions from -60 to 200°C
    • No annual leak testing required per EU 517/2014 F-Gas Regulation
    • Effective testing and conditioning of electronic components, boards, and modules
    • Available for 50 and 60Hz operation
    • No need for Liquid Nitrogen (LN2) or Liquid Carbon Dioxide (LCO2)
    • Remote communications and set up and touch screen operation
    • User Defined Temperature Limits

     

     

  • The new G5.RSS series features

    • High control dynamics
    • An exceptional accuracy
    • A nominal output voltage of up to 3000 VDC
    • A wide current-voltage range with an auto-ranging factor of 3.
    • You get the best value for your investment.

     

    • compact and completely modular design
    • high effectiveness in all operation modes, few requirements on building infrastructure
    • ability to use an existing liquid cooling system directly
    • optional matched liquid-to-air cooling unit TC.LAE available
    • possibility of upgrading to systems of up to 1 MVA
    • high level of system dynamics, ≤ 5 kHz modulation bandwidth
    • non-restrictive capability of refeeding in the Q4 operation mode
    • possibility of operating as an autonomous 4-Q and 3-phase quasi-analogue amplifier
    • possibility of “Hardware-in-the loop”-operation (HIL mode)
    • user friendly application software with pre-configured test patterns
    • possibility of integrating into a complete SAS simulation and test system
    • galvanic isolation available as an option without derating the simulator port data

     

  • Bidirectional (source & sink), Regenerative 0…65VDC to 0…1500VDC, 20kW up to 1.5 MW 

    • cell system nominal voltage and type of chemistry
    • number of cells
    • internal resistance and associated parameters
    • cell temperature progression
    • allowed current
    • charge efficiency
    • energy computing and management facilities
    • time-dependent and functional dependent parameters

     

    • Setting of operational parameters for each output phase: (frequency, phase, voltage, basic waveform)
    • Defining functional blocks enabling a wide variety of modulation capabilities
    • Defining, editing and storing of even complex and long test sequences
    • Preview window for output voltage waveforms
    • LC load mode, definition of complex equivalent circuits
    • Hand drawing curve tool and FOURIER tool (harmonics synthesis)
    • TC.ACS provides an extensive safety concept in order to detect unwanted or off-limit conditions very quickly and to initiate controlled limiting or even a shutdown.

     

    • compact and completely modular design
    • high effectiveness in all operation modes, few requirements on building infrastructure
    • ability to use an existing liquid cooling system directly
    • optional matched liquid-to-air cooling unit TC.LAE available
    • possibility of upgrading to systems of up to 1 MVA
    • high level of system dynamics, ≤ 5 kHz modulation bandwidth
    • non-restrictive capability of refeeding in the Q4 operation mode
    • possibility of operating as an autonomous 4-Q and 3-phase quasi-analogue amplifier
    • possibility of “Hardware-in-the loop”-operation (HIL mode)
    • user friendly application software with pre-configured test patterns
    • possibility of integrating into a complete SAS simulation and test system
    • galvanic isolation available as an option without derating the simulator port data

     

  • Photovoltaic applications, the quality and technical data of the AC-DC converter is of primary interest. Solar installations are intended for a lifetime of roughly 20 years, therefore even fractions of a percent in efficiency will represent significant amounts of energy losses.