1 800 665 7301 | info@tmetrix.com

    • Versatile Current Sensing: Accurately measure small and large currents, from sub-milliamp levels to thousands of amps.
    • High-Speed Pulse Monitoring: Patented distributed termination technology enables ultra-fast rise time measurement (as short as 2ns).
    • Enhanced Noise Immunity & Safety: Double shielding minimizes external noise, making these monitors ideal for high-voltage applications.
    • Robust Construction: Sealed models are suitable for high-voltage insulating oil or vacuum environments.
    • Broad Compatibility: Works with oscilloscopes, spectrum analyzers, power analyzers, digital voltmeters, ADCs, and more.

     

  • High-Precision Current Measurement with BNC Connectivity

    • Precision Current Sensing: ±1% accuracy ensures reliable real-time current monitoring.
    • BNC Connector for Seamless Connectivity: Works with oscilloscopes, ADCs, spectrum analyzers, and power analyzers.
    • Clamp-On Design for Non-Intrusive Measurement: Safely monitor live current flow without circuit disruption.
    • 50 Ohm Termination Compatible: Output reduces by half when using a 50Ω termination.
    • High-Voltage Safety Considerations: Conductive case requires adequate insulation for user safety.

     

  • High-Precision Current Sensing with BNC Connectivity

    • High-Precision Measurement: ±1% accuracy for reliable current sensing.
    • Customizable Configurations: Designed to meet specific user requirements for precision measurement.
    • BNC Connector for Easy Integration: Works with oscilloscopes, ADCs, spectrum analyzers, and power analyzers.
    • Non-Insulated Conductive Case: Proper insulation must be provided on the monitored conductor.
    • 50 Ohm Termination Compatibility: Using a 50Ω termination reduces the output to half.

     

  • High-Precision Voltage Measurement Up to 500kV

    • High-Voltage Measurement Capability: Supports up to 500kV in insulating oil and customizable calibration for air use.
    • Precision Division Ratios: Models with 5000:1, 10,000:1, and custom ratios, ensuring reliable voltage scaling.
    • Temperature-Compensated Accuracy: ±1% over 20°C to 80°C, providing stable voltage readings.
    • Robust Design for Harsh Environments: Sealed for high-voltage insulating oil use, with custom air calibration available.
    • Safe Operation with Ground Loop Control: The outer conductor is isolated from the case, allowing controlled grounding connections.

     

  • Precision Pulse Output Up to 500kV

    • Wide Voltage Range: Supports 100kV to 500kV pulse outputs for high-energy applications.
    • Fast Pulse Transmission: Pulse durations from 0.25 to 50 microseconds, ensuring efficient energy transfer.
    • Insulating Oil Immersion: Open-construction design for operation in high-voltage insulating oil, reducing breakdown risks.
    • Advanced Overvoltage Protection: Designed with built-in safety factors (50-100%) to prevent damage from overvoltages.
    • Reliable Flashover Protection: Corona ring-to-core insulation prevents damage from accidental flashovers.

     

  • The new G5.RSS series features

    • High control dynamics
    • An exceptional accuracy
    • A nominal output voltage of up to 3000 VDC
    • A wide current-voltage range with an auto-ranging factor of 3.
    • You get the best value for your investment.

     

    • Dual inputs allows Differential or Phaseto-Phase voltage measurement
    • High speed DSP provides up to 60 filtered readings per second
    • True RMS AC measurement from 0.01Hz to 600Hz—covering VLF to aviation frequencies
    • AC noise rejection 78dB—for rock solid, six digit DC Measurements
    • Optional battery pack goes up to 11 hours between charges
    • G Series—high input impedance probes for electrostatic applications
    • CE mark Certified to EN61010
    • Available ISO 17025 accredited calibration
    • Three year extended warranty (one year standard warranty)

     

    • The S type Channel card provides economical, high-performance power measurement with a basic 0.1% accuracy and enough bandwidth to handle waveforms up to 1.25 MHz.
    • The A-type ultra-precision Channel card offers a 2-year accuracy rating of 0.03% of reading and bandwidth up to 1.25 MHz.
    • The W type Wideband Channel card performs precision power measurements on the toughest real-world waveforms, with sampling speed fast enough to tame waveforms up to 5Mhz

     

    • The S type Channel card provides economical, high-performance power measurement with a basic 0.1% accuracy and enough bandwidth to handle waveforms up to 1.25 MHz.
    • The A-type ultra-precision Channel card offers a 2-year accuracy rating of 0.03% of reading and bandwidth up to 1.25 MHz.
    • The W type Wideband Channel card performs precision power measurements on the toughest real-world waveforms, with sampling speed fast enough to tame waveforms up to 5Mhz

     

    • The S type Channel card provides economical, high-performance power measurement with a basic 0.1% accuracy and enough bandwidth to handle waveforms up to 1.25 MHz.
    • The A-type ultra-precision Channel card offers a 2-year accuracy rating of 0.03% of reading and bandwidth up to 1.25 MHz.
    • The W type Wideband Channel card performs precision power measurements on the toughest real-world waveforms, with sampling speed fast enough to tame waveforms up to 5Mhz

     

  • • High Power Accuracy of 0.045% For All Channels
    • Improved Voltage and Current Self-Heating Adders
    • Faster Sampling Rates & Bandwidth Performance
    • Greater Harmonic Frequencies

     

  • • Ultra High Power Accuracy of 0.024% For All Channels
    • Improved Voltage and Current Self-Heating Adders
    • Faster Sampling Rates & Bandwidth Performance
    • Greater Harmonic Frequencies

     

    • 3″ Color Touch Display – Easy To Use Intuitive User Interface
    • 6 Functions Choose From – AC/DC Hipot, IR, Ground Bond, Continuity & Built-in Switching
    • Made in the USA – Designed & Built in San Diego CA
    • Compact, Lightweight, Rugged, Fan Free, Fast (100mS min test time) & Accurate
    • 5KV AC/DC Hipot, 20mA max source current
    • Ground Bond 1-30A RMS (42 A peak), 100µΩ Resolution
    • 100 nano-Amp Leakage Current Resolution
    • Low Cost of Ownership – 2 Year Calibration Interval

     

    • compact and completely modular design
    • high effectiveness in all operation modes, few requirements on building infrastructure
    • ability to use an existing liquid cooling system directly
    • optional matched liquid-to-air cooling unit TC.LAE available
    • possibility of upgrading to systems of up to 1 MVA
    • high level of system dynamics, ≤ 5 kHz modulation bandwidth
    • non-restrictive capability of refeeding in the Q4 operation mode
    • possibility of operating as an autonomous 4-Q and 3-phase quasi-analogue amplifier
    • possibility of “Hardware-in-the loop”-operation (HIL mode)
    • user friendly application software with pre-configured test patterns
    • possibility of integrating into a complete SAS simulation and test system
    • galvanic isolation available as an option without derating the simulator port data

     

  • Bidirectional (source & sink), Regenerative 0…65VDC to 0…1500VDC, 20kW up to 1.5 MW 

    • cell system nominal voltage and type of chemistry
    • number of cells
    • internal resistance and associated parameters
    • cell temperature progression
    • allowed current
    • charge efficiency
    • energy computing and management facilities
    • time-dependent and functional dependent parameters

     

    • Setting of operational parameters for each output phase: (frequency, phase, voltage, basic waveform)
    • Defining functional blocks enabling a wide variety of modulation capabilities
    • Defining, editing and storing of even complex and long test sequences
    • Preview window for output voltage waveforms
    • LC load mode, definition of complex equivalent circuits
    • Hand drawing curve tool and FOURIER tool (harmonics synthesis)
    • TC.ACS provides an extensive safety concept in order to detect unwanted or off-limit conditions very quickly and to initiate controlled limiting or even a shutdown.