AE Techron 4301 Series Telecom Test Systems

AE Techron 4301 Series Telecom Test Systems

Key Performance Capabilities:

  • Slew rates up to 60 V/µsec.
  • Up to 240A DC at +50VDC or –50VDC (4301-240 configuration).
  • Can provide pulses of up to 800 amps at voltages of up to ±100V (4301-240 configuration).
  • Adjustable compensation allows the system to maintain a 50V/2 µsec rise-time over a wide range of current outputs.

 

REQUEST A QUOTE
Category:



Introducing the AE Techron 4301 Series Telecom Test Systems

The 4301 Series Telecom Test Systems have been specially designed for EMC testing of network telecommunications equipment and are the best systems available for producing the waveforms required for transient voltage measurements as described in GR-1089 Section 10 and ATIS-0600315.2007.

The 4301 is designed to work with a standard arbitrary wave form generator or signal source that can be triggered. The system can be ordered with an optional Fluke 281 arbitrary waveform generator, which comes pre-programmed and integrated into the 4301 system. When equipped with the Fluke 281 option, the 4301 provides a complete solution for GR-1089 Section 10/ATIS-0600315.2007 testing.

The 4301 system is available in four standard configurations and is capable of slew rates of up to 60 V/µsec. In its largest configuration (model 4301-240), the 4301 system can provide up to 240A of DC at ±50VDC and can provide pulses of up to 800 amps at voltages of up to ± 100V. The system has a voltage gain of 20 and can accept input voltages of up to ±10V.

The system cabinets have been designed with space and power provisions for the installation of other electronics, if desired.

Lower power versions of the 4301 amplifier solution are available for users with lower current requirements: 4301-180 (180A), 4301-120 (120A) and 4301-60 (60A).

 

AE Techron 4301 Series Telecom Test Systems



AE Techron 4301 Series Telecom Test Systems

Key Features

Telecom Test Systems

  • Complete solution for GR-1089 Section 10 and ATIS-0600315.2007 DC Voltage Variations and Transients Testing
  • Designed to work with a standard arbitrary waveform generator or signal source that can be triggered
  • Optional Fluke 281 AWG comes pre-programmed and integrated into the 4301 system
  • Four selectable compensation settings
  • Cabinet design allows for additional customization

 



Key Benefits

Indicators and Controls

(4301 system amplifier modules)

LED Displays: Indicators for Run, Ready, Standby, and Stop status, and Fault conditions in the output stage.

LCD Display: Can be user-configured for up to four simultaneous displays reporting one, two, or all four of the following: Voltage Peak, Voltage RMS, Current Peak and Current RMS. When the amplifier module is in a Fault condition, the LCD Display lists the type of fault condition and gives suggested corrective action.

Navigation Buttons: The Navigation Buttons provide four arrow keys to allow navigation through the various LCD display options.

Soft Touch Switches: Soft touch switches allow the selection of Run (Enable), Stop and Reset functions.


AE Techron 4301 Series Telecom Test Systems


Trust the Experts at ACA TMetrix Inc.

ACA TMetrix Inc. is a leading Canadian distributor of test and measurement instruments and design tools. For over 55 years we have provided products manufactured by the world’s leading instrument manufacturers. Leading Distributor of Design Tools and Test Equipment in Canada.

Specifications

4301-60

Maximum Continuous DC Current (±50 VDC):60A
Maximum Pulse DC Current (up to ±100 VDC): 200A
Voltage Gain: 20
Maximum Input Voltage: ±10V, unbalanced
Compensation Setting (for current required at system output),
Setting 0 (off):
 0 to 6A;
   Setting 1: 6 to 12A
   Setting 2: 12 to 50A
   Setting 3: 50 to 60A
Current Monitor Output: 20A output = 1V monitor output
Voltage Monitor Output: 20V output = 1V monitor output
Required AC Mains, three-phase, 47-60 Hz, five-conductor wiring (±10%),
208 VAC: 
30A AC service;
   400 VAC: 15A AC service
Dimensions (HxWxD): 27 x 34 x 22.5 in. (68.6 x 86.4 x 57.2 cm)
Net Weight: 307 lbs. (139 kg)
Shipping Weight: 458 lbs. (208 kg)

4301-120

Maximum Continuous DC Current (±50 VDC):120A
Maximum Pulse DC Current (up to ±100 VDC): 400A
Voltage Gain: 20
Maximum Input Voltage: ±10V, unbalanced
Compensation Setting (for current required at system output),
Setting 0 (off):
 0 to 12A;
   Setting 1: 12 to 24A
   Setting 2: 24 to 100A
   Setting 3: 100 to 120A
Current Monitor Output: 40A output = 1V monitor output
Voltage Monitor Output: 10V output = 1V monitor output
Required AC Mains, three-phase, 47-60 Hz, five-conductor wiring (±10%),
208 VAC:
 60A AC service;
   400 VAC: 30A AC service
Dimensions (HxWxD): 52 x 22 x 31.5 in. (132 x 55.9 x 80 cm)
Net Weight: 454 lbs. (206 kg)
Shipping Weight: 589 lbs. (267 kg)

4301-180

Maximum Continuous DC Current (±50 VDC):180A
Maximum Pulse DC Current (up to ±100 VDC): 600A
Voltage Gain: 20
Maximum Input Voltage: ±10V, unbalanced
Compensation Setting (for current required at system output),
Setting 0 (off):
 0 to 18A;
   Setting 1: 18 to 36A
   Setting 2: 36 to 150A
   Setting 3: 150 to 180A
Current Monitor Output: 60A output = 1V monitor output
Voltage Monitor Output: 10V output = 1V monitor output
Required AC Mains, three-phase, 47-60 Hz, five-conductor wiring (±10%),
208 VAC:
 90A AC service;
   400 VAC: 45A AC service
Dimensions (HxWxD): 74 x 22 x 31.5 in. (188 x 55.9 x 80 cm)
Net Weight: 697 lbs. (316 kg)
Shipping Weight: 897 lbs. (407 kg)

4301-240

Maximum Continuous DC Current (±50 VDC):240A
Maximum Pulse DC Current (up to ±100 VDC): 800A
Voltage Gain: 20
Maximum Input Voltage: ±10V, unbalanced
Compensation Setting (for current required at system output),
Setting 0 (off):
 0 to 24A;
   Setting 1: 24 to 50A
   Setting 2: 50 to 200A
   Setting 3: 200 to 240A
Current Monitor Output: 80A output = 1V monitor output
Voltage Monitor Output: 10V output = 1V monitor output
Required AC Mains, three-phase, 47-60 Hz, five-conductor wiring (±10%),
208 VAC: 
120A AC service;
   400 VAC: 60A AC service
Dimensions (HxWxD): 74 x 22 x 31.5 in. (188 x 55.9 x 80 cm)
Net Weight: 850 lbs. (386 kg)
Shipping Weight: 1050 lbs. (476 kg)

Datasheet


Get in touch with us to inquire about our tailored consulting services.