Aim-TTi MX100QP Bench / System

Aim-TTi MX100QP Bench / System

Multi-Range DC Power Supply with digital control, 3 or 4 Outputs, 315 to 420W with/without Remote Interfaces

  • hree or four high performance outputs each with full functionality
  • Range switching gives variable voltage/current combinations
  • Shared power mode provides double power from a single output
  • Low output noise and ripple via linear final regulation
  • High setting resolution of up to 1mV and 0.1mA
  • Variable OVP and OCP trips on all outputs
  • 50 setting memories per output plus 50 linked memories
  • Selectable voltage tracking (isolated tracking)
  • Selectable current meter averaging
  • Switchable remote sense capability
  • Graphic LCD provides simultaneous output metering
  • Numeric or spin-wheel control of all parameters
  • Individual or combined output on/off control with programmable delay sequencing.
  • 3U half-rack case for bench or rack mounting (4U rack kit accessory available)
  • RS-232, USB and LAN (LXI) interfaces (P models), GPIB option
  • Duplicate power & sense terminals at rear (P models)

 

REQUEST A QUOTE
Category:



Introducing the Aim-TTi MX100QP Bench / System

The MX series uses mixed mode regulation to provide up to 420W of power split across up to four outputs, this series differs from most other multi-output power supplies in offering full capabilities on all outputs.

Each output features CV or CI operation, simultaneous high resolution metering, switchable remote sensing, OVP and OCP trips, and an individual output switch. To increase its ability to match the widest range of applications, each output has more than one range giving the choice of higher voltage or higher current.

When higher power is required, up to two outputs can be disabled to provide twice the power from one or two outputs – up to 210 watts for the MX100T/MX100Q and up to 360 watts for the MX180T

 

Aim-TTi MX100QP Bench / System



Aim-TTi MX100QP Bench / System

Key Features

  • Three or four high performance outputs each with full functionality
  • Range switching gives variable voltage/current combinations
  • Shared power mode provides double power from a single output
  • Low output noise and ripple via linear final regulation
  • High setting resolution of up to 1mV and 0.1mA
  • Variable OVP and OCP trips on all outputs
  • 50 setting memories per output plus 50 linked memoriesT
  • Selectable voltage tracking (isolated tracking)
  • Selectable current meter averaging
  • Switchable remote sense capability
  • Graphic LCD provides simultaneous output metering
  • Numeric or spin-wheel control of all parameters
  • Individual or combined output on/off control with programmable delay sequencing.
  • 3U half-rack case for bench or rack mounting (4U rack kit accessory available)
  • RS-232, USB and LAN (LXI) interfaces (P models), GPIB option
  • Duplicate power & sense terminals at rear (P models)

 



Key Benefits


Aim-TTi MX100QP Bench / System


Trust the Experts at ACA TMetrix Inc.

ACA TMetrix Inc. is a leading Canadian distributor of test and measurement instruments and design tools. For over 55 years we have provided products manufactured by the world’s leading instrument manufacturers. Leading Distributor of Design Tools and Test Equipment in Canada.

Specifications

OUTPUT 3 & 4 ( OUTPUT 4 MX100Q & MX100QP ONLY)
Setting accuracy: Voltage: ±(0.1% of reading + 10mV)
Current: ±(0.3% of reading + 3mA to 3A)
Ripple and noise:
(20MHz bandwith)
Front terminals: Typically <0.5mV rms, <5mV pk-pk, 1mV rms max.
70V range: typically <1mV rms, <10mV pk-pk, 1.5mV rms max.
Transient response:
(of set level for 5% to 95% load change)
Front terminals:<150µs to within 50mV
Rear Terminals:<175µs to within 50mV
Over voltage trip: Settable 1V to 80V in 0.1V steps
Over current trip: Settable 0.1A to 3.5A in 0.01A steps
OUTPUT PROTECTION Output will withstand forward voltages of up to 50V (O/P1 & O/P2), or 80V (O/P3, O/P4).
Reverse protection by diode clamp, 3A max.
Fault trip: The output will be shut down if a trip condition listed below occurs.
OVP or OCP: Exceeding the over-voltage or over-current settings for the output.
Over temperature: Monitors internal temperature rise to protect against excess ambient temperature or blocked ventilation slots.
CONNECTIONS
Output terminals: Universal 4mm safety binding posts on 19mm (0.75”) at front. Screw terminals at rear (P-models only)
Terminals can accept fixed shroud 4mm plugs, standard 4mm plugs, fork terminals and bare wires.
OUTPUT ON/OFF SWITCHING
Individual on/off: Individual keys for each output. On state indicated by key illumination.
Multi-on/ multi-off: Separate keys enable any combination of outputs to be turned on or off either simultaneously (default) or with timed delays from
10ms to 20s. Delayed operation indicated by flashing key illumination.
Tracking modes: V2 tracks V1
V4 tracks V3
V2 tracks V1 & V4 tracks V3

 

 