The MX series uses mixed mode regulation to provide up to 420W of power split across up to four outputs, this series differs from most other multi-output power supplies in offering full capabilities on all outputs.
Each output features CV or CI operation, simultaneous high resolution metering, switchable remote sensing, OVP and OCP trips, and an individual output switch. To increase its ability to match the widest range of applications, each output has more than one range giving the choice of higher voltage or higher current.
When higher power is required, up to two outputs can be disabled to provide twice the power from one or two outputs – up to 210 watts for the MX100T/MX100Q and up to 360 watts for the MX180T
ACA TMetrix Inc. is a leading Canadian distributor of test and measurement instruments and design tools. For over 55 years we have provided products manufactured by the world’s leading instrument manufacturers. Leading Distributor of Design Tools and Test Equipment in Canada.
OUTPUT 3 & 4 ( OUTPUT 4 MX100Q & MX100QP ONLY) | |
Setting accuracy: | Voltage: ±(0.1% of reading + 10mV) Current: ±(0.3% of reading + 3mA to 3A) |
Ripple and noise: (20MHz bandwith) |
Front terminals: Typically <0.5mV rms, <5mV pk-pk, 1mV rms max. 70V range: typically <1mV rms, <10mV pk-pk, 1.5mV rms max. |
Transient response: (of set level for 5% to 95% load change) |
Front terminals:<150µs to within 50mV Rear Terminals:<175µs to within 50mV |
Over voltage trip: | Settable 1V to 80V in 0.1V steps |
Over current trip: | Settable 0.1A to 3.5A in 0.01A steps |
OUTPUT PROTECTION | Output will withstand forward voltages of up to 50V (O/P1 & O/P2), or 80V (O/P3, O/P4). Reverse protection by diode clamp, 3A max. |
Fault trip: | The output will be shut down if a trip condition listed below occurs. |
OVP or OCP: | Exceeding the over-voltage or over-current settings for the output. |
Over temperature: | Monitors internal temperature rise to protect against excess ambient temperature or blocked ventilation slots. |
CONNECTIONS | |
Output terminals: | Universal 4mm safety binding posts on 19mm (0.75”) at front. Screw terminals at rear (P-models only) Terminals can accept fixed shroud 4mm plugs, standard 4mm plugs, fork terminals and bare wires. |
OUTPUT ON/OFF SWITCHING | |
Individual on/off: | Individual keys for each output. On state indicated by key illumination. |
Multi-on/ multi-off: | Separate keys enable any combination of outputs to be turned on or off either simultaneously (default) or with timed delays from 10ms to 20s. Delayed operation indicated by flashing key illumination. |
Tracking modes: | V2 tracks V1 V4 tracks V3 V2 tracks V1 & V4 tracks V3 |
Datasheet