Hioki benchtop battery testers support simultaneous high-speed measurement of the internal resistance and battery voltage of EV and PHEV battery packs. The BT3564 Battery HiTester can measure pack voltage and total resistance, as well as bus bar resistance up to 1000V.
Key Features
- Measure high-voltage battery packs up to 1000V
- Production line testing of high-voltage battery packs for EV, PHEV
- 0.1 μΩ to 3000 Ω internal resistance range (pack total resistance, bus bar resistance)
- Spark discharge reduction function
- Analog output function
- Optional measurement probe available for 1000 V and high-voltage battery packs
|
|
Maximum input voltage 1000V.High voltage battery tester for EV and PHEV.
The BT3564 simultaneously measures both internal resistance and battery voltage with an input voltage of up to 1000 V. This battery tester is perfect for shipping and receiving inspections of battery packs ranging from increasingly higher voltage EV and PHEV batteries to home storage batteries. Hioki Battery HiTester BT3564 |
|
|
Probe supports 1000 V and high voltage battery packs (option)
Safely and smoothly measure high voltage battery packs with the 1000 V probe. |
|
|
Built-in spark discharge reduction function
Easily connect high accuracy clamp-type sensors without cutting the cables. Sensors operate over a temperature range of -40°C to 85°C (-40°F to 185°F), characteristics that enable highly accurate measurements even inside the engine room of a car. |
|
|
Analog output function
Complete with a built-in resistance value analog output function. Combine it with a recorder or logger for total resistance value monitoring.
|
Specifications
Basic specifications (Accuracy guaranteed for 1 year, Post-adjustment accuracy guaranteed for 1 year)
Max. applied measurement voltage |
± 1000 VDC rated input voltage
± 1000 VDC max. rated voltage to earth |
Resistance measurement ranges |
3 mΩ (max. display 3.1000 mΩ, resolution 0.1 μΩ) to 3 kΩ (max. display 3.1000 kΩ, resolution 0.1 Ω), 7 ranges
Accuracy: ±0.5 % rdg. ±5 dgt. (30 mΩ to 3 kΩ range), ±0.5 % rdg. ±10 dgt. (3 mΩ range)
Testing source frequency: 1 kHz ±0.2 Hz, testing current: 100 mA (3 mΩ range) to 10 μA (3.000 kΩ range)
Open terminal Voltage: 25 V peak (3/30 mΩ ranges), 7 V peak (300 mΩ range), 4 V peak (3 Ω to 3.000 kΩ range) |
Voltage measurement ranges |
10 V DC (resolution: 10 µV) to 1000V DC (resolution: 1 m V), 3 ranges
Accuracy: ±0.01 % rdg. ±3 dgt. |
Display |
31000 full digits (resistance), 999999 full digits (voltage, 1000 V range: 999999 or 110000), LED |
Sampling time |
FAST: 12 ms, MEDIUM: 35 ms, SLOW: 253 ms
(Typ., sampling time depends on supply frequency settings and function.) |
Total measurement time |
Response time + sampling time (Response time for both resistance and voltage are reference value of about 700 ms, depends on measurement object.) |
Comparator functions |
Judgment result: Hi/IN/Lo (resistance and voltage judged independently)
Setting: Upper and lower limit, Deviation (%) from reference value
Logical ANDed result: PASS/FAIL, calculates the logical AND of resistance and voltage judgment results.
Result display, beeper, or external I/O output (open-collector, 35 V, 50 mA DC max.) |
Analog output |
Measured resistance (displayed value, from 0 to 3.1 V DC) |
Interface |
External I/O, RS-232C, Printer (RS-232C), GP-IB |
Power supply |
100 to 240 V AC, 50/60 Hz, 30 VA max. |
Dimensions and mass |
215 mm (8.46 in) W × 80 mm (3.29 in) H × 295 mm (12.95 in) D, 2.4 kg (84.7 oz) |
Accessories |
Instruction manual ×1, Power cord ×1 , Operating Precautions ×1 |
|