Discount Products: Look through products available for a 25% – 50% discount in 2020. The items provided on a first come, first serve basis.
View Discounted Products

IMPEDANCE ANALYZER IM3570

IMPEDANCE ANALYZER IM3570

Wide band 4Hz to 5Mz Impedance Analyzer for High Speed Testing and Frequency Sweeping of Piezoelectric Elements, Functional Polymer Capacitors, Coils and Transformers

 

REQUEST A QUOTE



Description

Hioki LCR Meters and Impedance Analyzers range from 1mHz to 1.3GHz devices to suit a wide range of applications in the testing of electronic components. The IM3570 is ideal for use in applications requiring low-ESR measurement on the order of several milliohms, for example testing of functional polymer capacitors, due to its superior low-impedance repeatability. IMPEDANCE ANALYZER IM3570

Order Code

IM3570

This product is not supplied with measurement probes or test fixtures. Please select and purchase the measurement probe or test fixture options appropriate for your application separately. For an RS-232C connection: A crossover cable for interconnection can be used. You can use the RS-232C CABLE 9637 without hardware flow control.

RS232Coption            USB2optionCE LANGPIB

Key Features

• LCR, DCR, sweep, and continuous measurement with high-speed testing in a single unit

• Maximum test speeds of 1.5ms (1 kHz) and 0.5ms (100kHz) in LCR mode

• High basic accuracy of Z parameter: ±0.08% • Ideal for testing the resonance characteristics of piezoelectric elements, C-D and low ESR measurement of functional polymer capacitors, DCR and L-Q measurement of inductors (coils and transformers)

• Perform frequency sweeps, level sweeps, and time interval measurements in analyzer mode

• Support for high-speed switching of measurement conditions

■ Basic specifications (Accuracy guaranteed for 1 year, Post-adjustment accuracy guaranteed for 1 year)

 

Measurement modes

 

LCR mode, Analyzer mode (Sweeps with measurement frequency and measurement level), Continuous measurement mode

 

Measurement parameters

 

Z, Y, θ, Rs (ESR), Rp, Rdc (DC resistance), X, G, B, Cs, Cp, Ls, Lp,
D (tanδ), Q

 

Measurement range

 

100 mΩ to 100 MΩ, 12 ranges (All parameters are determined according to Z)

 

 

Display range

 

 

Z, Y, Rs, Rp, Rdc, X, G, B, Ls, Lp, Cs, Cp :
±(0.000000 [unit] to 9.999999G [unit], Absolute value display for Z and Y only
θ : ±(0.000° to 180.000°), D : ±(0.000000 to 9.999999)
Q : ±(0.00 to 99999.99), Δ % : ±(0.0000% to 999.9999%)

 

Basic accuracy

 

Z ±0.08% rdg. θ: ±0.05°

 

Measurement frequency

 

4 Hz to 5 MHz (5 digits setting resolution, minimum resolution 10 mHz)

 

Measurement signal level

 

Normal mode:
V mode/CV mode: 5 mV to 5 Vrms (up to 1 MHz)
10 mV to 1 Vrms (1.0001 MHz to 5 MHz), 1 mVrms steps
CC mode: 10 μA to 50 mArms (up to 1 MHz)
10 μA to 10 mArms (1.0001 MHz to 5 MHz), 10 μArms steps
Low impedance high accuracy mode:
V mode/CV mode: 5 mV to 1 Vrms (up to 100 kHz), 1 mVrms steps
CC mode:10 μA to 100 mArms (100 mΩ and 1Ω ranges of up to 100 kHz), 10 μArms steps

 

Output impedance

 

Normal mode: 100 Ω, Low impedance high accuracy mode: 10 Ω

 

Display

 

5.7-inch color TFT, display can be set to ON/OFF

 

Measurement time

 

0.5 ms (100 kHz, FAST, display OFF, representative value)

 

Functions

 

DC bias measurement, Comparator, BIN measurement (classification), Panel loading/saving, Memory function

 

Interfaces

 

EXT I/O (handler), RS-232C, GP-IB, USB communication, USB memory, LAN

 

Power supply

 

90 to 264 V AC, 50/60 Hz, 150 VA max.

 

Dimensions and mass

 

330 mm (12.99 in) W × 119 mm (4.69 in) H × 307 mm (12.09 in) D, 5.8 kg (204.6 oz)

 

Accessories

 

Power cord × 1, Instruction manual × 1, PC communication instruction manual (CD-R) × 1

Get in touch with us to inquire about our tailored consulting services.