1 800 665 7301 | info@tmetrix.com

  • ThermoSpot Systems – Benchtop Direct Contact Cooling and Heating Solution

    The Temptronic® ThermoSpot® delivers high-performance temperature control for IC testing and high-Watt devices with unmatched cooling capacity.

    Key Features:

    • Reliable thermal cycling without thermoelectric modules
    • Wide temperature range: -65°C to +175°C
    • Cooling power: 40W at -40°C, 55W at -55°C, 120W at -40°C
    • Fast transitions: <35 seconds from +25°C to -40°C
    • Secure thermal contact with ThermoBridge™ design
    • Touch-screen with data logging and programmable settings
    • Multiple communication ports: Ethernet, USB, IEEE, RS232

     

  • ThermoSpot® Systems – Direct Contact Thermal Test Solutions

    Key Features:

    • Temperature range: -65°C to +175°C
    • Cooling power up to 120W at -40°C
    • Fast transition rate (<35 sec from +25°C to -40°C)
    • Reliable thermal cycling without thermoelectric modules
    • Flexible thermal probe with interchangeable ThermoBridge™
    • Touchscreen controller with programmable profiles
    • Connectivity options: Ethernet, USB, IEEE, RS232
    • Easy, secure connection to in-circuit or socketed DUTs

  • Key Features:

    • Free-standing turntable designed for electromagnetic absorption chambers
    • 0.3 m diameter with 50 kg load capacity
    • Height: 190 mm, made of rigid PVC skin-foam sheets
    • Rotating speed adjustable from 0.1 rpm to 2.5 rpm
    • High positioning accuracy of ±0.5°
    • Rotation angle: -200° to 400° with synchronous servo motor
    • LAN (TCP/IP) control option via FCU3.0 or NCD Controller
    • Central 50 mm opening for power supply insertion
    • Interference suppression: 20 dB under DIN EN 55011:2018-05 class B
    • Ideal for automotive, telecom, medical, and industrial EMC testing

     

  • The TT 1.0 PF Turn Table is a precision turntable designed for EMC and RF testing in anechoic and electromagnetic absorption chambers.

    Key Features:

    • Diameter: 1.0 m; height: 190 mm
    • Load capacity up to 100 kg
    • Free-standing design for chamber floor installation
    • Adjustable rotation speed: 0.1–2.5 rpm
    • Positioning accuracy: ±0.5°
    • Rotating angle range: -200° to 400°
    • Central 50 mm opening for power supply connections
    • Controlled via LAN (TCP/IP) with FCU3.0 or NCD Controllers
    • Durable PVC integral skin-foam cover plate
    • Synchronous servo motor with toothed belt and worm gear drive

     

  • A professional-grade video generator designed for testing Dolby Vision, HDR, and DSC on DisplayPort™ 1.4a sink devices. Ideal for R&D debugging, compliance testing, and high-resolution validation.

    Key Features:

    • Supports 8K @ 30 Hz and 4K @ 120 Hz resolutions (8K @ 60 Hz with DSC)
    • DP 1.4a Link Layer CTS tool for sink testing*
    • HDCP 2.2/2.3 CTS tool for transmitter compliance*
    • HDR and Dolby Vision test capability with 32 GB extended memory
    • Supports DSC, FEC, LTTPR, and MST (4 streams)
    • USB-C output with included converter
    • No restrictions on video format, audio format, frame rate, or infoframes

     

  • A versatile and cost-effective interoperability test solution for HDMI 1.4 source devices, designed to streamline R&D debugging and automated testing.

    Key Features:

    • HDMI 1.4 and DisplayPort interface support
    • Compatible with TSI Test System Interface API
    • Ready-made test routines for streamlined functionality testing
    • Comprehensive analysis of video, audio, CEC, and metadata
    • Ideal for testing Blu-Ray players, laptops, set-top boxes, game consoles, and tablets
    • Supports both R&D debugging and test automation environments

     

  • VRC Reverb Tent Chamber is a flexible, modular electromagnetic test facility designed for immunity and emission testing with high efficiency and portability.

    Key Features:

    • Flexible metallic fabric tent construction
    • Wide frequency range (up to 18 GHz)
    • Mechanical vibration walls (5–20 Hz) for uniform reverberation
    • Faster test throughput compared to traditional methods
    • Modular, customizable dimensions for large or small DUTs
    • Compliant with IEC 61000-4-21 and MIL-STD-461 standards
    • Easy to assemble, disassemble, and transport
    • Optional accessories: antennas, filters, control rooms

     

  • The CDG 7000 is a new test generator for all standards on immunity to conducted disturbances induced by high-frequency fields – including BCI tests (ISO 11452-4). One of the very few combined IEC 61000-4-6 test systems that contain the RF signal generator, an RF power amplifier, a 3-channel RF voltmeter, and a directional coupler at a very affordable price. IEC 60601-1-2 calling out IEC 61000-4-39 magnetic immunity for close proximity testing requirements can also now be met with the 10 kHz unit.

  • The new G5.RSS series features

    • High control dynamics
    • An exceptional accuracy
    • A nominal output voltage of up to 3000 VDC
    • A wide current-voltage range with an auto-ranging factor of 3.
    • You get the best value for your investment.

     

    • compact and completely modular design
    • high effectiveness in all operation modes, few requirements on building infrastructure
    • ability to use an existing liquid cooling system directly
    • optional matched liquid-to-air cooling unit TC.LAE available
    • possibility of upgrading to systems of up to 1 MVA
    • high level of system dynamics, ≤ 5 kHz modulation bandwidth
    • non-restrictive capability of refeeding in the Q4 operation mode
    • possibility of operating as an autonomous 4-Q and 3-phase quasi-analogue amplifier
    • possibility of “Hardware-in-the loop”-operation (HIL mode)
    • user friendly application software with pre-configured test patterns
    • possibility of integrating into a complete SAS simulation and test system
    • galvanic isolation available as an option without derating the simulator port data

     

  • Bidirectional (source & sink), Regenerative 0…65VDC to 0…1500VDC, 20kW up to 1.5 MW 

    • cell system nominal voltage and type of chemistry
    • number of cells
    • internal resistance and associated parameters
    • cell temperature progression
    • allowed current
    • charge efficiency
    • energy computing and management facilities
    • time-dependent and functional dependent parameters

     

    • Setting of operational parameters for each output phase: (frequency, phase, voltage, basic waveform)
    • Defining functional blocks enabling a wide variety of modulation capabilities
    • Defining, editing and storing of even complex and long test sequences
    • Preview window for output voltage waveforms
    • LC load mode, definition of complex equivalent circuits
    • Hand drawing curve tool and FOURIER tool (harmonics synthesis)
    • TC.ACS provides an extensive safety concept in order to detect unwanted or off-limit conditions very quickly and to initiate controlled limiting or even a shutdown.

     

    • compact and completely modular design
    • high effectiveness in all operation modes, few requirements on building infrastructure
    • ability to use an existing liquid cooling system directly
    • optional matched liquid-to-air cooling unit TC.LAE available
    • possibility of upgrading to systems of up to 1 MVA
    • high level of system dynamics, ≤ 5 kHz modulation bandwidth
    • non-restrictive capability of refeeding in the Q4 operation mode
    • possibility of operating as an autonomous 4-Q and 3-phase quasi-analogue amplifier
    • possibility of “Hardware-in-the loop”-operation (HIL mode)
    • user friendly application software with pre-configured test patterns
    • possibility of integrating into a complete SAS simulation and test system
    • galvanic isolation available as an option without derating the simulator port data

     

  • Photovoltaic applications, the quality and technical data of the AC-DC converter is of primary interest. Solar installations are intended for a lifetime of roughly 20 years, therefore even fractions of a percent in efficiency will represent significant amounts of energy losses.

  • Programmable Grid-tie Sink High-Power DC Supply,

  • Programmable Grid-tie Source & Sink Technology
    Wide range of power 20 to 512 kW, expandable up to several MW
    DC output voltages from 0-65 VDC up to 0-1500 VDC, +/- 40 A up to +/- 600 A